Jump to content

OverridableParameterTerminal class/Fixed-Point.Representation.Actual.Range Max property: Difference between revisions

From LabVIEW Wiki
m Category reorg
Updated for LabVIEW 2020
 
(2 intermediate revisions by the same user not shown)
Line 2: Line 2:
| classid = 16515
| classid = 16515
| propertyid = 794E2C0F
| propertyid = 794E2C0F
| scope=private
| scope=script
| dataname = FXP Actual Range Max
| dataname = FXP Actual Range Max
| shortname = FXPActualRangeMax
| shortname = FXPActualRangeMax
Line 9: Line 9:
| datatype = Double Float
| datatype = Double Float
| propertynodeimage = OverridableParameterTerminal-Fixed-Point-Representation-Actual-Range Max.png
| propertynodeimage = OverridableParameterTerminal-Fixed-Point-Representation-Actual-Range Max.png
| permissions = Write Only
| availableinrealtime = No
| availableinruntime = No
| loadsbd = No
| loadsfp = No
| needsauthentication = No
| permissions = Read Only
| remoteallowed = Yes
| settablewhenrunning = No
|}}
|}}
{{TOCright}}
{{TOCright}}


Reads the actual maximum of the fixed-point value based on its encoding.


== Uses ==
== Uses ==
Line 18: Line 26:


== History ==
== History ==
{{ambox|text=History information is needed.  What changes have occurred over previous versions?}}
{| class="wikitable"
{| class="wikitable"
! Version
! Version
! Change(s)
! Change(s)
|-
|-
|[[File:LV2018.png|frameless|border|64x64px|LabVIEW 2018|link=LabVIEW 2018]]
|[[File:LV2020.png|frameless|border|64x64px|LabVIEW 2020|link=LabVIEW 2020]]
|More info to come.
| In [[LabVIEW 2020]] this property was changed from [[VI Server#Private|Private]] to [[VI Server#VI Scripting|VI Scripting]].
|}
|}
== See Also ==
== See Also ==
{{ambox|text=Add links to internal wiki pages that would also help.}}
{{ambox|text=Add links to internal wiki pages that would also help.}}
Line 32: Line 40:
{{ambox|text=Add links to external resources that would also help.}}
{{ambox|text=Add links to external resources that would also help.}}


[[Category:VI Scripting Property]]
[[Category:VI Server Property]]
[[Category:VI Server Property]]

Latest revision as of 02:45, 17 June 2020

VI Server Property Information
Property ID 794E2C0F
Scope VI Scripting
Data Name FXP Actual Range Max
Short Name* FXPActualRangeMax
Long Name* Fixed-Point:Representation:Actual:Range Max
* Displayed here in English. Short and Long names appear in the language of the LabVIEW IDE.
Owning Class ID 16515
Owning Class Name OverridableParameterTerminal Class
Data Type Double Float data type

Double Float

Property Node Fixed-Point:Representation:Actual:Range Max
Available in Real-Time Operating SystemNo
Available in Run-Time EngineNo
Loads the block diagram into memoryNo
Loads the front panel into memoryNo
Need to authenticate before useNo
PermissionsRead Only
Remote access allowedYes
Settable when the VI is runningNo

Reads the actual maximum of the fixed-point value based on its encoding.

Uses

History

Version Change(s)
LabVIEW 2020 In LabVIEW 2020 this property was changed from Private to VI Scripting.

See Also

External Links