Jump to content

OverridableParameterTerminal class/Fixed-Point.Representation.Desired.Range Max property: Difference between revisions

From LabVIEW Wiki
m Added Private Property Category to page
Updated for LabVIEW 2020
 
(One intermediate revision by the same user not shown)
Line 2: Line 2:
| classid = 16515
| classid = 16515
| propertyid = 794E2C0B
| propertyid = 794E2C0B
| scope=private
| scope=script
| dataname = FXP Desired Range Max
| dataname = FXP Desired Range Max
| shortname = FXPDesiredRangeMax
| shortname = FXPDesiredRangeMax
Line 9: Line 9:
| datatype = Double Float
| datatype = Double Float
| propertynodeimage = OverridableParameterTerminal-Fixed-Point-Representation-Desired-Range Max.png
| propertynodeimage = OverridableParameterTerminal-Fixed-Point-Representation-Desired-Range Max.png
| availableinrealtime = No
| availableinruntime = No
| loadsbd = No
| loadsfp = No
| needsauthentication = No
| permissions = Read/Write
| permissions = Read/Write
| remoteallowed = Yes
| settablewhenrunning = No
|}}
|}}
{{TOCright}}
{{TOCright}}


Reads or writes the desired maximum of the fixed-point value based on its encoding.


== Uses ==
== Uses ==
Line 18: Line 26:


== History ==
== History ==
{{ambox|text=History information is needed.  What changes have occurred over previous versions?}}
{| class="wikitable"
{| class="wikitable"
! Version
! Version
! Change(s)
! Change(s)
|-
|-
|[[File:LV2018.png|frameless|border|64x64px|LabVIEW 2018|link=LabVIEW 2018]]
|[[File:LV2020.png|frameless|border|64x64px|LabVIEW 2020|link=LabVIEW 2020]]
|More info to come.
| In [[LabVIEW 2020]] this property was changed from [[VI Server#Private|Private]] to [[VI Server#VI Scripting|VI Scripting]].
|}
|}
== See Also ==
== See Also ==
{{ambox|text=Add links to internal wiki pages that would also help.}}
{{ambox|text=Add links to internal wiki pages that would also help.}}
Line 31: Line 39:
== External Links ==
== External Links ==
{{ambox|text=Add links to external resources that would also help.}}
{{ambox|text=Add links to external resources that would also help.}}
[[Category:Private Property]]


[[Category:VI Scripting Property]]
[[Category:VI Server Property]]
[[Category:VI Server Property]]

Latest revision as of 02:39, 17 June 2020

VI Server Property Information
Property ID 794E2C0B
Scope VI Scripting
Data Name FXP Desired Range Max
Short Name* FXPDesiredRangeMax
Long Name* Fixed-Point:Representation:Desired:Range Max
* Displayed here in English. Short and Long names appear in the language of the LabVIEW IDE.
Owning Class ID 16515
Owning Class Name OverridableParameterTerminal Class
Data Type Double Float data type

Double Float

Property Node Fixed-Point:Representation:Desired:Range Max
Available in Real-Time Operating SystemNo
Available in Run-Time EngineNo
Loads the block diagram into memoryNo
Loads the front panel into memoryNo
Need to authenticate before useNo
PermissionsRead/Write
Remote access allowedYes
Settable when the VI is runningNo

Reads or writes the desired maximum of the fixed-point value based on its encoding.

Uses

History

Version Change(s)
LabVIEW 2020 In LabVIEW 2020 this property was changed from Private to VI Scripting.

See Also

External Links