Jump to content

OverridableParameterTerminal class/Fixed-Point.Representation.Bits.Signed property: Difference between revisions

From LabVIEW Wiki
Added new property page.
 
Updated for LabVIEW 2020
 
(3 intermediate revisions by the same user not shown)
Line 2: Line 2:
| classid = 16515
| classid = 16515
| propertyid = 794E2C06
| propertyid = 794E2C06
| scope=private
| scope=script
| dataname = FXP Signed
| dataname = FXP Signed
| shortname = FXPSigned
| shortname = FXPSigned
Line 9: Line 9:
| datatype = Boolean
| datatype = Boolean
| propertynodeimage = OverridableParameterTerminal-Fixed-Point-Representation-Bits-Signed.png
| propertynodeimage = OverridableParameterTerminal-Fixed-Point-Representation-Bits-Signed.png
| availableinrealtime = No
| availableinruntime = No
| loadsbd = No
| loadsfp = No
| needsauthentication = No
| permissions = Read/Write
| permissions = Read/Write
| remoteallowed = Yes
| settablewhenrunning = No
|}}
|}}
{{TOCright}}
{{TOCright}}


Reads or writes whether the fixed-point value is a signed value. FALSE means unsigned. Using this property with a non-fixed-point numeric will result in an error.


== Uses ==
== Uses ==
Line 18: Line 26:


== History ==
== History ==
{{ambox|text=History information is needed.  What changes have occurred over previous versions?}}
{| class="wikitable"
{| class="wikitable"
! Version
! Version
! Change(s)
! Change(s)
|-
|-
|[[File:LV2018.png|frameless|border|64x64px|LabVIEW 2018|link=LabVIEW 2018]]
|[[File:LV2020.png|frameless|border|64x64px|LabVIEW 2020|link=LabVIEW 2020]]
|More info to come.
| In [[LabVIEW 2020]] this property was changed from [[VI Server#Private|Private]] to [[VI Server#VI Scripting|VI Scripting]].
|}
|}
== See Also ==
== See Also ==
{{ambox|text=Add links to internal wiki pages that would also help.}}
{{ambox|text=Add links to internal wiki pages that would also help.}}
Line 32: Line 40:
{{ambox|text=Add links to external resources that would also help.}}
{{ambox|text=Add links to external resources that would also help.}}


[[Category:Property]] [[Category:VI Server Property]]
[[Category:VI Scripting Property]]
[[Category:VI Server Property]]

Latest revision as of 01:36, 17 June 2020

VI Server Property Information
Property ID 794E2C06
Scope VI Scripting
Data Name FXP Signed
Short Name* FXPSigned
Long Name* Fixed-Point:Representation:Bits:Signed
* Displayed here in English. Short and Long names appear in the language of the LabVIEW IDE.
Owning Class ID 16515
Owning Class Name OverridableParameterTerminal Class
Data Type Boolean data type

Boolean

Property Node Fixed-Point:Representation:Bits:Signed
Available in Real-Time Operating SystemNo
Available in Run-Time EngineNo
Loads the block diagram into memoryNo
Loads the front panel into memoryNo
Need to authenticate before useNo
PermissionsRead/Write
Remote access allowedYes
Settable when the VI is runningNo

Reads or writes whether the fixed-point value is a signed value. FALSE means unsigned. Using this property with a non-fixed-point numeric will result in an error.

Uses

History

Version Change(s)
LabVIEW 2020 In LabVIEW 2020 this property was changed from Private to VI Scripting.

See Also

External Links