VI Server Property Information
|
Property ID
|
4F483C4A
|
Scope
|
Basic Development Environment
|
Data Name
|
Alarming.U32BitField.AlarmOn
|
Short Name*
|
Alarming.U32BitField.AlarmOn
|
Long Name*
|
Alarming:U32BitField:Alarm On
|
* Displayed here in English. Short and Long names appear in the language of the LabVIEW IDE.
|
Owning Class ID
|
81
|
Owning Class Name
|
Variable Class
|
Data Type
|
Enum U16 data type
|
Property Node
|
|
Available in Real-Time Operating System | No |
Available in Run-Time Engine | No |
Loads the block diagram into memory | No |
Loads the front panel into memory | No |
Need to authenticate before use | No |
Permissions | Read/Write |
Remote access allowed | Yes |
Settable when the VI is running | Yes |
Gets or sets whether a shared variable generates an alarm when any bit (1
) is in alarm state or only when all bits (0
) are in alarm state. To use this property, you must install the LabVIEW Datalogging and Supervisory Control Module.
This option is valid only when the Alarming:U32BitField:Enabled property is TRUE.
Note You can enable alarming only for network-published shared variables.
|
This property is similar to the Alarm On option on the Alarming page of the Shared Variable Properties dialog box.
Uses
History
Version
|
Change(s)
|
|
More info to come.
|
See Also
External Links