NI Instruction Framework Error Code Family

From LabVIEW Wiki
Jump to: navigation, search

Below are all of the Error Codes that belong to the NI Instruction Framework Error Code Family (see Error List for list of Families).

Code Description
-1074101888 The register read command timed out.
-1074101887 The register write command timed out.
-1074101886 Bus instance exceeds the maximum number of bus instances.
-1074101885 Failed to read subsystem map. Device does not have correct signature. This could be due to a problem with the instruction target.
-1074101884 Failed to acquire subsystem map lock. The bus may be stalled. You may need to reset your target.
-1074101883 Failed to look up the address space with the parameters specified. The corresponding address space might not be instantiated and connected to the instruction framework on the target. You may need to load a different bitfile on your FPGA target.
-1074101882 Version check error. Address space version is too old. Upgrade your firmware, or recompile your FPGA bitfile with newer library versions.
-1074101881 Version check error. Address space version is too new. Upgrade your software, or use a compatible bitfile.
-1074101880 Invalid subsystem parameter.
-1074101879 Invalid address parameter.
-1074101878 An error occured when flattening address spaces. The address spaces may be too large to fit into one subsystem.
-1074101877 Version check error. Insruction Framework FPGA library is too old. Upgrade your firmware, or recompile your FPGA bitfile with a newer version of the Instruction Framework.
-1074101876 Version check error. Insruction Framework FPGA library is too new. Upgrade your software, or use a compatible bitfile.
-1074101875 The Register Port FIFO has overflowed. Contact National Instruments.
-1074101874 An FPGA subsystem returned an unknown non-negative error code.
-1074101873 A timeout occurred while waiting for Register Port reset to complete.
-1074101872 A timeout occurred while waiting for space in the Register Port input FIFO.
-1074101871 An unexpected hardware failure occurred on the Instruction FIFO.
-1074101870 A timeout occurred while waiting for space in the Instruction FIFO.
-1074101869 A timeout occurred while waiting for a response from the Instruction FIFO.
-1074101868 Failed to initialize the Instruction FIFO, due to an unexpected signature.
-1074101867 Version check error. The Instruction FIFO FPGA library is outdated and is no longer supported by the software. Upgrade your firmware, or recompile your FPGA bitfile with newer source.
-1074101866 Version check error. Your software is outdated and is no longer supported by the Instruction FIFO FPGA library. Upgrade your software, or use a compatible bitfile.
-1074101865 An internal software error has occurred. The Instruction FIFO returned an unexpected read completion. Please contact technical support at http://ni.com/support.
-1074101864 Version check error. Instruction framework plugin version is too old.
-1074101863 Version check error. Instruction framework plugin version is too new.