Code Description
-1074101504 Configuration error.
-1074101503 The class called does not implement this method. Use a child class that implements this method.
-1074101502 Onboard PLL failed to lock.
-1074101501 FPGA PLL failed to lock.
-1074101500 ADC PLL failed to lock.
-1074101499 ADC config error.
-1074101498 Invalid value.
-1074101497 One or more channels are overloaded.
-1074101496 One or more DRAM Banks failed to initialize.
-1074101495 The revision of the Configuration library compiled into the FPGA bitfile is too new for the current Host software. Upgrade the software to a version compatible with the revision of the Configuration library contained in the FPGA bitfile. Alternatively, recompile the FPGA bitfile or obtain a new FPGA bitfile that uses a version of the Configuration FPGA library compatible with the software.
-1074101494 The revision of the Configuration library compiled into the FPGA bitfile is too old for the current Host software. Recompile the FPGA bitfile or obtain a new FPGA bitfile that uses a version of the Configuration FPGA library compatible with the software. Alternatively, downgrade the software to a version compatible with the revision of the Configuration library compiled into the FPGA bitfile.
-1074101493 A clock fault has occurred. Re-download the FPGA or reboot the system. To avoid this error in future, connect an external clock with correct frequency and power at all times while the ADC clock is configured for an external source. Before removing the external clock, disable the FPGA data clock or reconfigure the ADC clock to an internal source.
-1074101492 A hardware failure related to the power rails on the daughtercard has occurred.
-1074101491 ADC communication error has occurred. Re-download the FPGA or reboot the system. If the error persists, contact NI technical support at ni.com/support.
-1074101490 A device initialization error has occurred. Re-download the FPGA or power cycle your chassis.
-1074101414 The current clocking configuration does not support export clock. Reconfigure the clock to a supported clocking configuration listed in the help manual.
-1074101413 The current clocking configuration does not support phase DAC adjustment. Reconfigure the clock to a supported clocking configuration listed in the help manual.
1073382155 A clock fault has occurred. Re-download the FPGA or reboot the system. To avoid this error in future, connect an external clock with correct frequency and power at all times while the ADC clock is configured for an external source. Before removing the external clock, disable the FPGA data clock or reconfigure the ADC clock to an internal source.