VI Server Property Information
|
Property ID
|
311C4C04
|
Scope
|
Basic Development Environment
|
Data Name
|
PipeWidth
|
Short Name*
|
PipeRadius
|
Long Name*
|
Pipe Radius
|
* Displayed here in English. Short and Long names appear in the language of the LabVIEW IDE.
|
Owning Class ID
|
130
|
Owning Class Name
|
MultiSegmentPipe Class
|
Data Type
|
U32 data type
|
Property Node
|
|
Available in Real-Time Operating System | Yes |
Available in Run-Time Engine | Yes |
Loads the block diagram into memory | No |
Loads the front panel into memory | No |
Need to authenticate before use | No |
Permissions | Read/Write |
Remote access allowed | Yes |
Settable when the VI is running | Yes |
Gets or sets the radius of the pipe segments in a pipe network. All pipe segments in a pipe network have the same radius.
The pipe radius is the distance, in pixels, between the center of a pipe segment to the edge of the pipe segment. The maximum pipe radius is one pixel less than the radius of the narrowest flange. The radius of a flange is equal to the pipe radius plus the flange width. The minimum pipe radius is five pixels. LabVIEW returns an error if you specify a pipe radius greater than the maximum or less than the minimum pipe radius.
The following illustration shows the pipe radius.
<img src="loc_fp_pipe_radius.gif">
You also can set the pipe radius interactively.