DISCLAIMER: Information here is purely processed data. There is no way to keep the data synchronized with NI Website. The idea was to gather all official related data to bugs and known issues in one place. If you find a mistake you are allowed to fix it. If you have new data, you are allowed to include it.


Bug Number Description Reported Version Resolved Version Added
1000558 LabVIEW can crash when the Class Hierarchy window is open and missing dependency

If there is a class or interface which has a missing dependency class or interface and the LabVIEW Class Hierarchy window is open and the missing dependency is selected when you close the project or quit LabVIEW, a crash may be encountered.

Workaround:

Deselect the missing item before closing or close the Class Hierarchy window

LabVIEW 2020 LabVIEW 2020 f1 Aug 31, 2020
1000943 Passing 1D and 2D arrays of strings between LabVIEW and TestStand is slow

Passing 1D and 2D arrays of strings between LabVIEW 2020 and TestStand using LabVIEW Run-Time Engine causes slowdowns.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 LabVIEW 2020 SP1 Dec 2, 2020
1004078 Unnecessary Compilation Occurs when a source distribution is set to remove object code

If the Separate compiled code from all source files option is selected when creating a source distribution, LabVIEW compiles the project before saving the source files.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2017 LabVIEW 2020 SP1 Dec 2, 2020
1009119 XControls do not load correctly when placed in subVI

When a XControl is placed in a subVI, the XControl may not appear.

Workaround:

Temporarily fix by redropping the XControl in the subVI, but the problem will return when the VI is loaded again. No workaround for built applications.

LabVIEW 2020 LabVIEW 2020 f1 Aug 31, 2020
1013965 Slow application build times for some projects in LabVIEW 2020

Building large projects into applications or other distributables takes longer in LabVIEW 2020 compared to LabVIEW 2019 SP1.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 LabVIEW 2020 SP1 Dec 2, 2020
1014647 LabVIEW hangs when the LabVIEW CLI tries to disconnect from the target LabVIEW instance

Automated build systems using the LabVIEW CLI can cause LabVIEW to hang sometimes when disconnecting in the middle of a build.

Workaround:

Avoid trying to disconnect while building.

LabVIEW 2019 LabVIEW 2020 f1 Aug 31, 2020
1019181 Unable to install package: ni-vipm

An error can occur during the LabVIEW 2020 installation which prevents the install of the package ni-vipm

Workaround:

Deselect VI Package Manager when installing

LabVIEW 2020 LabVIEW 2020 f1 Aug 31, 2020
1027690 Upgrading LabVIEW 2019 source to LabVIEW 2020 results in some VIs appearing broken

Upgrading source from LabVIEW 2019 to LabVIEW 2020 breaks some VIs.

Workaround:

Mass compiling the broken VIs or making cosmetic changes and saving can help in some cases.

LabVIEW 2020 LabVIEW 2020 SP1 Dec 2, 2020
103315 Creating a circular link between an Xcontrol and a LVClass can crash LabVIEW.

The circular load leads to VIs that are permanently broken and no matter what you do the run arrow will not become fixed.

Workaround:

Do not create a circular link from your XControl to your class. In other words, write your class completely and then write your XControl using the class. Do not put the XControl or any property/invoke node for the XControl into member VIs of the class.

LabVIEW 8.5.1 N/A 11/17/2009
1035177 Flattening and unflattening variants of a set corrupts name information

When flattening and unflattening the variant data into string data from the Insert Into Set VI, the name information gets corrupted. For example, the first two characters in the name get dropped from the name within the variant data itself or strings of random data get appended to the end of the name.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2019 N/A Jan 6, 2021
1043411 RFmx Memory leak in LabVIEW 2020

Large RFmx applications could see large memory leaks under some circumstances

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 LabVIEW 2020 f1 Aug 31, 2020
1047200 VI for Override Throws Error 7 when overriding Packed Library with Debugging Enabled in LabVIEW 2020

Try to create an override VI in a child class which inherits from a parent inside a Packed Project Library and debugging is enabled, it fails with Error 7.

Workaround:

Build override VI manually.

LabVIEW 2020 LabVIEW 2020 f1 Aug 31, 2020
1048670 LabVIEW crashes with id 0xC0000005 when using some forms of error tracing

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 LabVIEW 2020 f1 Aug 31, 2020
1054394 Restarting a BeagleBone Black using System Configuration causes crash

Connecting to a BeagleBone Black target using the LINX toolkit that is connected to the host via USB LAN can cause the host system to hang and crash.

Workaround:

There is currently no known workaround for this issue.

LabVIEW System Configuration: 20.0 LabVIEW 2020 SP1 Dec 2, 2020
1054835 SHA-256/SHA-224 results are incorrect for some message sizes

LabVIEW returns the wrong value for a SHA-256 and SHA-224 for message sizes56, 120, ..., (N*64&#43,56) bytes

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 LabVIEW 2020 f1 Aug 31, 2020
105509 The "do not save automatic changes" setting does not affect libraries

The "do not save automatic changes" options setting does not affect any type of library, including classes.

Workaround:

N/A

LabVIEW 8.0 N/A 06/20/2008
1055195 "Casting Utility For Actors.vim" causes dependency issue when used in a PPL

Workaround:

Edit new messages to separate from the VIM

LabVIEW 2020 LabVIEW 2020 f1 Aug 31, 2020
1056583 Right-clicking on a class wire/terminal/control when when right-click plugins causes crash

When using right-click plugins, LabVIEW can sometimes crash if right clicking on a class wire, terminal, or control.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 LabVIEW 2020 f1 Aug 31, 2020
1057446 Dynamic Dispatch method overrides do not save updates

In specific situations, changes made to method overrides will not save. Reopening the VI after saving changes will show the previous code. This prevents users from updating Dynamic Dispatch VIs for child classes.

Workaround:

None

LabVIEW 2020 LabVIEW 2020 f1 Aug 31, 2020
1059425 Newly created class overrides of Interface methods will sometimes not save

Sometimes LabVIEW silently fails to save and erases all edits to newly created class overrides of Interface methods.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 LabVIEW 2020 SP1 Dec 2, 2020
1066777 FTP Get Path Info.vi gives incorrect response

Create a \222 directory on your FTP server. If you copy one file to the \222 directory, connect to the server, and input a path such as \111\222, FTP Get Path Info.VI returns the file even though the path does not exist

Workaround:

Delete the \222 folder and the VI recognizes that the path does not exist.

LabVIEW 2016 N/A Jan 6, 2021
1072837 Casting Utility For Actors.vim has incorrect error handling

When messages are created for interfaces there may be incorrect error handling behavior due to wiring in the Casting Utility For Actors.vim

Workaround:

Modify the VIM manually

LabVIEW 2020 LabVIEW 2020 f1 Aug 31, 2020
1078977 LabVIEW 2020 crashes when using the File >> New.. dialog and selecting Class or Interface

Workaround:

Add a class by right clicking and selecting New >> Class or Interface

LabVIEW 2020 LabVIEW 2020 f1 Aug 31, 2020
1079302 LabVIEW crashes when encountering a broken dynamic dispatch VI called from TestStand

When a TestStand step calls a dynamic dispatch VI, the step is configured to call the base class version of the dynamic dispatch VI. If the dynamic dispatch member VI that corresponds to the class input is broken, LabVIEW may hang and crash.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2019 LabVIEW 2020 SP1 Dec 2, 2020
1123769 LabVIEW 2020 may crash on launch on macOS 11.0 Big Sur

LabVIEW 2020 may crash on launch on macOS 11.0 due to a graphics stack issue.

Workaround:

Run the following commands from Terminal: defaults write com.ni.labview NSGraphicsContextAllowOverRestore -bool YESdefaults write com.ni.labview NSViewAllowsRootLayerBacking&amp,nbsp,-bool NO

LabVIEW 2020 LabVIEW 2020 SP1 Dec 2, 2020
1126029 LabVIEW 2020 doesn't display UI feedback correctly on macOS 11.0 (Big Sur)

LabVIEW 2020 incorrectly displays selection rectangles, marching ants selection boundaries, dragged objects, and block diagram wiring feedback when run on Big Sur.

Workaround:

Run the following command from Terminal: defaults write com.ni.labview NSViewAllowsRootLayerBacking -bool NO

LabVIEW 2020 LabVIEW 2020 SP1 Dec 2, 2020
1135156 EXE containing Malleable VIs can only run when Enable Debugging and Disconnect Unused Inline SubVIs are selected

Codebases with many classes and Malleable VIs can have problems when building EXEs. In some cases, the EXE process starts but the code never runs. If you build with Enable Debugging selected, the EXE will have a broken run arrow and refers to a broken Malleable VI.

Workaround:

Build with Enable Debugging and Disconnect unused inline SubVIs selected.

LabVIEW 2020 N/A Jan 6, 2021
1146185 LabVIEW fails to save changes when moving a VI between virtual folders

LabVIEW fails to save changes when moving VI from one virtual folder to another within a .lvclass or .lvlib.

Workaround:

Move the VI to the new virtual folder and change the scope to anything else. Then change it back to the original one. This will save the changes and the next time you open LV, the VI will be in the specified virtual folder.Move the VI to the new virtual folder and change the scope to a different option and then back again.

LabVIEW 2020 N/A Jan 6, 2021
1146643 LabVIEW Crashes When Playing Sound File Repeatedly without Calling Sound Output Clear

Playing sound files repeatedly without calling "Sound Output Clear" crashes LabVIEW.

Workaround:

Call "Sound Output Clear" after playing a sound file.

LabVIEW 2020 LabVIEW 2023 Q1 N/A
1156197 Play Sound File VI interruption after several thousand iterations

After several thousand iterations, the Play Sound File VI stops playing the sound for one iteration. This behavior repeats every several thousand iterations.

Workaround:

The issue happens less frequently on 64-bit LabVIEW and could be considered a workaround depending on the application.

LabVIEW 2020 SP1 N/A Jan 6, 2021
1156638 Set up for Acquire Sound Express VI in Mac OS 14.10 causes a memory leak

Adding the Acquire Sound Express VI to the block diagram and waiting on the setup window causes memory leak in Mac OS Mojave 14.10.

Workaround:

Close setup window before the memory leak uses too much memory.

LabVIEW 2020 N/A Jan 6, 2021
1158778 NIPM does not discover the LabVIEW 2020 f1 Update

Workaround:

Fixed in the LabVIEW 2019 SP1 f3 and LabVIEW 2020 f1 patches.

LabVIEW 2019 SP1 LabVIEW 2020 f1 Aug 31, 2020
1159698 LLB does not reliably update when VI is modified post-build

When a post-build action modifies a VI in an LLB and the LLB is copied to another folder, the copied LLB contains an old version of the modified VI and does not match the LLB originally created by the Build Spec.

Workaround:

The VI in the LLB needs to be modified in something other than a post-build action.

LabVIEW 2020 N/A Jan 6, 2021
1165082 Race condition with an array of notifiers and a For Loop

When building an array of notifiers and connecting the Build Array function to a For Loop, the second iteration of the loop will timeout while waiting on a notification.

Workaround:

Index out the two notifiers and operate on them independently instead of in a For Loop. Make a data dependency so that either Obtain Notifier 1 and/or Send Notification 1 are guaranteed to execute before Send Notification 2.

LabVIEW 2019 N/A Jan 6, 2021
1166235 Mic/camera permissions on macOS may not associate properly

A VI requiring mic or camera permissions may not be able to access these system resources or prompt the user for permission.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2019 | LabVIEW: 2020 LabVIEW 2020 SP1 Dec 2, 2020
1176457 Event Structure Always Preserves Space for Event Data Node

An event structure with the Auto Grow option enabled will preserve space for the Event Data Node even if the Event Data Node is not visible.

Workaround:

There is currently no known workaround for this issue.

N/A LabVIEW 2021 SP1 Jan 6, 2022
1182809 IMAQ Create Executes More Slowly with Additional Calls in Built Applications

In a LabVIEW project, the right-click "Replace with" operation on a library can fail to update some VIs in the project. This issue affects VIs that reference the original library only through a dynamic dispatch call to a class method that is inherited from a parent class and not overridden by the child class wired to the call.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 LabVIEW 2021 SP1 Nov 2, 2021
119444 Multi-column listbox format lost on upgrade

A Multicolumn listbox created in LV 7.1 may lose its format when opened in LV 8.5 or later. Column headers lose their 3D appearance and font formatting might be lost.

Workaround:

Replace the Listbox and recreate all customizations

LabVIEW 8.5 N/A 07/12/2008
120686 Write to LabVIEW Measurement Files (LVM) using Express VIs takes up a lot of memory

The "Write to Measurement File" Express VI consumes a large amount of memory when writing to a Text File (LVM). However, the memory usage is smaller when the same Express VI is used to write a TDM/TDMS File

Workaround:

Use general LabVIEW VIs (and not Express VIs) to perform an LVM write for large amounts of data. The other option would be to write in smaller chunks.

LabVIEW 7.1 N/A 08/11/2008
1210828 Crash When Using Array Size Inside For Loop That Indexes a Set

When running a VI that iterates over a Set of Arrays with a For Loop and uses the Array Size function on an element, LabVIEW will crash. If you save the VI, then LabVIEW will crash when loading the VI.

Workaround:

Convert the set to an array before operating on the elements. Fixed in the LabVIEW 2019 SP1 f4 Patch.

LabVIEW 2019 LabVIEW 2021 May 6, 2021
1229501 Memory Leak When Using "Get Next Non-Text Sibling.vi"

LabVIEW leaks memory when using "Get Next Non-Text Sibling.vi" fromNI_XML.lvlib.

Workaround:

Fixed in the LabVIEW 2019 SP1 f4 Patch.

LabVIEW 2020 LabVIEW 2021 May 6, 2021
1249120 Crash if Variant to Data Processes ActiveX Data and the Output Is Not Wired

Workaround:

Fixed in the LabVIEW 2019 SP1 f4 Patch.

LabVIEW 2020 LabVIEW 2021 May 6, 2021
1271213 Slow Execution of Comparison of Variants Containing Large Data

LabVIEW makes unnecessary copies of data when doing comparison operations with Variants, which can result in slower performance in LabVIEW 2017 compared to earlier versions.

Workaround:

Fixed in the LabVIEW 2019 SP1 f4 Patch.

N/A LabVIEW 2021 May 6, 2021
1271283 Some EXEs built in 2017 SP1 do not work with the 2020 RTE

In rare instances, EXEs built in LabVIEW 2017 SP1 with the "Allow future versions of the LabVIEW runtime to run this application" option enabled freeze when using the LabVIEW 2020 Runtime Engine.

Workaround:

Upgrade to the LabVIEW 2020 SP1 Runtime Engine.

LabVIEW 2017 SP1 LabVIEW 2020 SP1 Feb 22, 2020
128059 Shared variable bindings in the same library are not updated properly when copying/renaming the library

If you have shared variables in a library which are bound to I/O servers or other variables that are also in the same library, and you rename or save a copy of the library, the bindings still refer to the original library name.

Workaround:

Manually rebind the variables after copying or renaming the library.

LabVIEW 8.0 N/A 04/28/2009
1335783, 1859807, 2065508 Using the DAQAssistant with DAQmx 2022 Q3 on LabVIEW 2022 Q3 Fails to Generate Code

Using the DAQAssistant on LabVIEW 2022 Q3 with DAQmx 2022 Q3 installed fails to configure the DAQAssistant node and gives the following code generation error: "LabVIEW Code Generation failed to execute.This may occur if the code gen engine is not properly installed, or if you are using a LabVIEW version under development" . Other workflows that use the DAQ Assistant to generate DAQmx tasks also fail.

Workaround:

Install LabVIEW 2021 SP1LabVIEW 2021 SP1 does not need to be activated, it is sufficient to install LabVIEW 2021 on your system and not activate it Installing just the LabVIEW 2021 SP1 run-time engine will not be sufficient, the LabVIEW ADE needs to be installed

LabVIEW 2022 Q3 | NI-DAQmx 2022 Q3 | NI-DAQmx 2023 Q1 N/A Aug 2, 2022
136677 Remote panels do not work if Internet Explorer is embedded in an ActiveX or .NET Container

If a remote panel is built in LabVIEW 8.6 and embedded in an ActiveX or .NET Container in a LabVIEW 8.6 VI it will not display correctly

Workaround:

Use a remote subpanel. This is actually the recommended way to accomplish this task

LabVIEW 8.6 N/A 10/01/2010
141699 NI Distributed System Manager does not show deployed libraries if they contain non-Latin characters.

If a library with non-Latin characters (such as Japanese, Chinese, or Korean) is deployed, it will not show up in the NI Distributed System Manager tree view.

Workaround:

Rename the library using only the Latin alphabet and re-deploy the library.

LabVIEW 2009 32-bit N/A 02/10/2009
1484666 Random Number (Range).vi U64 Can Generate Numbers Greater Than Upper Bound

The U64 instance of the polymorphic Random Number (Range) VI can generate numbers greater than the specified upper bound.

Workaround:

Test if the generated number is inside the specified range, and generate another value if it isn't.

LabVIEW 2020 N/A Aug 12, 2021
1500249 Sets and Maps Incorrectly Treat Some VI References as Equal

Inserting a VI reference as a key into a Set or Map can incorrectly fail and return True for "key already included?" when a different reference to the same VI already exists in the set or map, even if the existing reference was obtained separately and has a different reference value or refers to a different clone instance of the VI than the reference being inserted.

Workaround:

Use the "Clone Name" property or another unique attribute of the VI rather than a VI reference as the key to a set or map datatype when looking up values based on VI instances.

LabVIEW 2019 LabVIEW 2021 SP1 Oct 14, 2021
1392758 TDMS Async VIs Provide Incorrect Data on Last Iteration when Read Channel-by-channel in a Loop

When you use the TDMS Advanced Async VIs to read data out of a file with multiple channels in a For Loop, the final iteration can provide incorrect/missing data.

Workaround:

Include the Start Asynchronous Read and Stop Asynchronous Read functions inside the loop, so they execute on every iteration.

LabVIEW 2021 f1 N/A Aug 12, 2021
1510208 Distributed System Manager Displays Stale Information in LabVIEW Chinese

In LabVIEW Chinese, the Distributed System Manager can show out-of-date information.

Workaround:

Move the window and the Distributed System Manager will refresh to show current information.

LabVIEW 2021 N/A Aug 12, 2021
1513139 Malleable VIs Are Sometimes Erroneously Broken When Operating on Cluster Data Value References

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 LabVIEW 2021 SP1 Jan 6, 2022
1518822 Change Parent Interfaces Dialog Does Not Allow Removal of Missing Interface

If a class or an interface inherits from an interface that is missing on disk, the Change Parent Interfaces dialog does not provide a way to remove that parent.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 LabVIEW 2021 SP1 Jan 6, 2022
1521038 LabVIEW for Linux Crashes on Exit after Using RFSA Self-Calibration VIs

In Linux, loading a DLL built in a different version of LabVIEW than the version loading may cause LabVIEW to crash on exit. Using the NI-RFSA Self-Calibration VIs could lead to this crash.

Workaround:

Fixed in the LabVIEW 2021 SP1 f2 Patch.

LabVIEW 2021 LabVIEW 2021 SP1 f2 Jun 27, 2022
1528110 Objects Are Not Added to Sets and Maps If Parent Interfaces Are Present

When adding objects to a set or map, if they inherit from interfaces that are also in the set or map, those objects are erroneously excluded.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2021 LabVIEW 2021 SP1 Jan 6, 2022
1529057 Ctrl-Delete Keyboard Shortcut Does Not Remove Array Element

Using the keyboard shortcut Ctrl-Delete can appear to remove an array element but does not update the value of the array.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 SP1 LabVIEW 2021 SP1 Jan 6, 2022
153731 Unhandled Exception can occur if absolute path for system DLL used in CLFN

If you use a specific path to a system DLL (C:\windows\system\user32.dll) and build your VI into an application it will create a copy of the DLL inside the application. This can cause an unhandled exception when running

Workaround:

LabVIEW searches in the system directory when looking for DLLs. If you are using a system DLL simply put the name in the in DLL Path box in the CLFN properties. In the example above you would simply put "user32.dll"

LabVIEW 8.6 N/A 07/23/2010
1539898 LabVIEW Crashes When Removing Class Member VI With Recursive Caller

LabVIEW may crash when removing a dynamic dispatch method VI from a class. This happens if a child class doesn't implement the method but has a recursive call to it.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 LabVIEW 2021 SP1 Jan 6, 2022
1555422 Changes to MATLAB (.m) File Are Not Reflected after Running a Calling VI That Calls the .m File

When you drag a file from the File Explorer to a Path control or constant, the value of the path will have an extraneous NULL character at the end.

Workaround:

Manually delete the extra character after completing the drag and drop.Fixed in the LabVIEW 2021 SP1 f2 Patch.

LabVIEW 2021 SP1 LabVIEW 2022 Q3 Jun 27, 2022
1564621 Block Diagram Wires Sometimes Misaligned After Repositioning Functions

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2021 LabVIEW 2021 SP1 Jan 6, 2022
157246 The Property Node "Bring to Front" doesn't work in Windows Vista

Workaround:

N/A

LabVIEW 8.6.1 N/A 04/20/2009
1596011 Block Diagram Wire to Malleable VI is Broken Erroneously

A wire to a malleable VI can be broken even though the malleable VI accepts the type of the wire.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2019 LabVIEW 2021 SP1 Jan 6, 2022
1597634 LabVIEW Crashes When Setting Strings[] Property to Empty Array

The Custom Probes section of a wire's context menu does not display probes from &lt,Documents>\LabVIEW Data\Probes.

Workaround:

Remove a VI from a subpanel before closing its reference.

LabVIEW 2020 LabVIEW 2021 SP1 Jan 6, 2022
163371 "Save As:Copy" on a nested library breaks member VIs if use option to add copied library to owner library

Old Description :"Save As:Copy" on a nested library breaks member VIs if use option to add copied library to owner libraryIf you have a nested library, a library that is owned by another library, and you use Save As:Copy, there is an option to add the duplicate library to the original owner library. If you use this option, the member VIs of the duplicate library are all broken because they are not correctly named as members of the owning library.This bug affects all types of libraries, .lvlib, .lvclass, .xctl and .lvsc.

Workaround:

Option 1: Do not use the "add to owning library" option and instead add the duplicate library to the owner manually after the copy.

Option 2: After the copy operation, open and close one of the new VIs and then move the duplicate library out of the owner library. Browse to any missing VIs that pop up a browse dialog. Move the duplicate library back into the owner library.

LabVIEW 8.5 N/A 09/30/2009
166204 LabVIEW Class Property Node Doesn't Update with New Type Definition Name

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 SP1 LabVIEW 2023 Q3 Jul 20, 2023
166253 LabVIEW.app does not show up after LabVIEW 2009 Installation

Workaround:

This is only an issue for customers who installed the LabVIEW 2009 Beta for Mac. Delete /Library/Receipts/LabVIEW*9.0.pkg before running the LabVIEW 2009 installer for Mac OS.

LabVIEW 2009 32-bit LabVIEW Unknown 07/31/2009
166351 Get Date/Time String does not work for dates beyond 2/5/2040

When trying to get a string for dates 2/6/2040 and beyond, the Get Date/Time String will instead provide an earlier, incorrect date.

Workaround:

Use the Format Date/Time String VI instead of Get Date/Time String

LabVIEW 2013 SP1 N/A Feb 11, 2020
166364 Clicking greyed out option of the Scale Legend when using a Waveform Chart causes LabVIEW to crash

If you add a Waveform Chart to the Front Panel (without wiring anything to it on the Block Diagram) and then expand the Legend to include more Plots, set the Waveform Chart to Stacked Plots, make the Scale Legend visible, and then expand the Scale Legend to show more empty or greyed out y-scales, when you try to select any of the buttons on the greyed out portion, LabVIEW will crash.

Workaround:

If you wire any 2D array (even an empty 2D array of doubles) to the Waveform Chart before setting the Waveform Chart to Stacked Plots, the crash will not occur.

LabVIEW 2014 SP1 N/A Feb 11, 2020
166386 Incorrect behavior when using a Boolean control from the System palette

When using a Boolean control from the System palette and running the VI, you do not see the "hover" picture change. When clicked, the value stays consistent, but the button does not change visually.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2015 SP1 LabVIEW 2020 Apr 20, 2020
166394 DataSocket Write VI with default timeout can hang before proceeding

When using the DataSocket Write VI with the default 0 second timeout (or wiring in a 0 second timeout), the VI may hang for 10 seconds before completing.

Workaround:

Wire in a short timeout of several ms to the DataSocket Write VI.

LabVIEW 2017 SP1 N/A Feb 11, 2020
166505 Registering for an event for multiple boolean controls can fail in specific configurations

When passing a mixture of strict and non-strict boolean references in a cluster to the event source terminal of the Register For Events node, the input wire will break if any strict references are not the first elements of the cluster.

Workaround:

Use a Switch mechanical action, group the references with Build Array, or place any strict references at the beginning of the cluster.

LabVIEW 2016 N/A Feb 11, 2020
166601 LabVIEW Runtime Engine encounters Worker Thread Limit when using web services on Linux RT-based cRIO

On a Linux RT-based cRIO, the LabVIEW Runtime Engine can get into a deadlocked state waiting for action from the Web Server. This can cause process hangs resulting in a Worker Thread Limit error reported to the user by the Web Server.

Workaround:

Use a mechanism other than web services.

LabVIEW 2015 LabVIEW 2020 Feb 11, 2020
1667266 LabVIEW VI Window Title Only Uses Latin-1 Character Encoding on Linux

LabVIEW 2021 SP1 causes an increase in the memory usage of some applications unnecessarily over time.

Workaround:

You can disable the performance optimization which caused the memory leak by adding "MemoryManger.UseMasterPointerPool &#61, FALSE" to the LabVIEW INI file. LabVIEW 2021 SP1 f1 patch fixes the issue by disabling the performance optimization by default.

LabVIEW 2021 SP1 LabVIEW 2021 SP1 f1 Apr 22, 2022
1667279 Captions Using Application Font Do Not Display Non-English Characters on Linux

On Linux, LabVIEW defaults to using Helvetica for the Application Font, which cannot correctly display some non-English characters.

Starting in LabVIEW 2021 SP1, LabVIEW on Linux tries to match "sans" as the application and system fonts when the LANG does not match "en_*".

Workaround:

Configure the Application Font to a font that supports non-English characters.

LabVIEW 2021 LabVIEW 2021 SP1 f1 Jan 25, 2022
1887820 LabVIEW 2021 SP1 Leaks Memory

LabVIEW 2021 SP1 causes an increase in the memory usage of some applications unnecessarily over time.

Workaround:

You can disable the performance optimization which caused the memory leak by adding "MemoryManger.UseMasterPointerPool = FALSE" to the LabVIEW INI file. LabVIEW 2021 SP1 f1 patch fixes the issue by disabling the performance optimization by default.

LabVIEW 2021 SP1 LabVIEW 2021 SP1 f1 Apr 22, 2022
166772 Special characters (\r,\n, etc.) are not correctly converted to JSON when using LabVIEW Web services

When a LabVIEW Web service is set to the JSON output type, strings with special characters such as tab constant, carriage return constant, and end of line constant are not escaped properly. This does not include the /s character.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2015 SP1 LabVIEW 2020 Apr 20, 2020
168005 Dynamic Variable API Does Not Support I/O Servers that Use Ranges

You cannot use the Variable classes, properties, and methods or the associated Shared Variable functions (Dynamic Variable API) to dynamically read and write PSP items published by an I/O Server that uses a Range item. For example, Modbus I/O Servers and Lookout Ranges are affected by this issue.

Workaround:

If you want to use the Dynamic Variable API to read or write one of these PSP items, you can create a network-published shared variable and bind it to the PSP item. Then you can use the Dynamic Variable API to read and write the bound shared variable.

LabVIEW 2009 32-bit N/A 11/10/2009
168361 LabVIEW Class is Locked When Not Open in Multiple Contexts

When using the Map Get/Replace Value Structure with the In-Place Element Structure, if you manipulate the value from the "Get" structure with array functions, the key inside the map will not be overwritten with the manipulated data.

Workaround:

Edit the array data in some way, for example, by indexing and building the array after the "get" of the key.Fixed in the LabVIEW 2021 SP1 f2 Patch.

LabVIEW 2021 LabVIEW 2021 SP1 f2 , LabVIEW 2022 Q3 Jun 27, 2022
1692754 LabVIEW Crashes After Adding Parent Interface to Class With Missing Parent Interface

LabVIEW crashes after adding a parent interface to a class if the class inherits from a parent interface that cannot be found.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2021 LabVIEW 2021 SP1 Jan 6, 2022
169840 Large matrix operations that utilize the Intel MKL on Linux may crash LabVIEW

When one or more matrix operations consumes most of the system resources, the Intel MKL library produces an unhandled exception that results in a LabVIEW application crashing.This Intel library is used to accelerate fundamental linear algebra operations performed under Linux operating systems. This issue has been reproduced outside the LabVIEW execution environment and a bug report has been submitted to Intel.Because the crash is tied to system resources, it can manifest itself in many ways. For example, we have reliably reproduced the problem by:1. Decomposing a large matrix into multiple large matrices.Specific example: Computing the singular value decomposition (SVD) of a 2500-by-2500 matrix on a system with 256M RAM.2. Simultaneously computing multiple matrix operations using relatively small matrices.Specific example: Computing 30 matrix expressions using 300 x 300 matrices on a system with 512 MB RAM.

Workaround:

If you have identified one or more matrix operations in your application that exhibit this behavior, you have multiple options to avoid crashing.1. Serialize the matrix operations so that they are not consuming resources in parallel.2. Replace affected matrix arithmetic functions using Basic Linear Algebra Subroutine (BLAS)functions found on the BLAS palette.3. Structure your application so that these operations are not competing with other functions for system resources.

LabVIEW 2009 32-bit N/A 11/10/2009
1705840 Bundle by Name in Malleable VI Updates Wrong Cluster Item

If a cluster has a nested element with the same name as an element, a Bundle by Name function that is in a malleable VI and configured to the nested element can access the element instead of the nested element.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2018 | LabVIEW 2020 SP1 | LabVIEW 2021 LabVIEW 2021 SP1 Jan 6, 2022
1708546 LabVIEW Crashes After Moving TestStand UI Controls Out of Tab Control

Moving TestStand UI controls out of tab controls in a VI panel with a splitter bar may cause LabVIEW to crash.

Workaround:

Make a temporary change so that the XControl is broken before copying the VI.

LabVIEW 2019 SP1 LabVIEW 2021 SP1 Dec 2, 2021
1554752 LabVIEW Cannot Build Packages After Installing 64-bit LabVIEW 2019 SP1 f4 Patch

64-bit LabVIEW 2019 SP1 cannot build packages after you install the LabVIEW 2019 SP1 f4 patch because required support files are missing.

Workaround:

Fixed in LabVIEW 2019 SP1 f5 patch.

LabVIEW 2019 SP1 LabVIEW 2019 SP1 f5 Dec 2, 2021
170899 When building a web service into an EXE and making an installer, some software dependencies are not automatically selected as additional installers

If you build a web service into an EXE that has method VIs with software dependencies, such as the use of a hardware driver, only VIs with dependencies that are included as Startup VIs for the web service will be automatically selected as additional installers. Any method VI that is not a Startup VI will not have its software dependencies automatically selected.

Workaround:

Build the web service into the installer rather than the EXE or manually include the required software dependencies

LabVIEW 2015 SP1 N/A Feb 11, 2020
173080 When a project that contains variables with binding is created in one language and opened in a different language, variables may fail to deploy

Workaround:

Open the project in the desired language, double-click on the variables with binding, and re-bind the variables.

LabVIEW 8.6 N/A 09/08/2009
1753009 Usable IMAQdx Event Callback VI Cannot Be Created

After wiring an IMAQdx Session reference to the Register Event Callback function, creating a callback VI results in an incorrect callback VI reference.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 LabVIEW 2022 Q3 Jul 26, 2022
1754642 Startup VI Does Not Run in Applications That Use Web Services and NI Web Server

The Look In Map function can sometimes erroneously use an existing data allocation instead of making a unique copy, thereby producing outputs that break dataflow semantics.

Workaround:

Use the Always Copy function on any input wire to Look In Map, which is also wired to other functions.

LabVIEW 2021 LabVIEW 2022 Q3 Jul 26, 2022
1759565 LabVIEW Appends Extraneous NULL Character to Path When You Drag and Drop a File to a Path Control

When you drag a file from the File Explorer to a Path control or constant, the value of the path will have an extraneous NULL character at the end.

Workaround:

Manually delete the extra character after completing the drag and drop.Fixed in the LabVIEW 2021 SP1 f2 Patch.

LabVIEW 2021 SP1 LabVIEW 2021 SP1 f2 Jun 27, 2022
176848 Picture Control Stops Updating After Setting Properties to Default.

Once the picture control's values have reinitialized to default by selecting Data Operations»Reinitialize to Default or programmatically using the method Reinitialize to Default, the mouse position property node stops updating.

Workaround:

Replace the picture control with a new one from the palette.

LabVIEW 8.6.1 N/A 09/24/2010
1769482 LabVIEW Cannot Build a Packed Project Library If VI Without Block Diagram References Malleable VIs

Trying to build a Packed Project Library using a VI that references a malleable VI and does not have a block diagram results in the following incorrect error message. "Error 1073: Unable to for this application. Choose a different option on the Additional Exclusions page and build the application again." Contrary to the error message, there are no build options that will allow the build to succeed. You must remove the malleable VI reference from the VI before removing its block diagram.

Workaround:

When removing block diagrams from VIs, disconnect any malleable VI references first.

LabVIEW 2021 SP1 N/A Jan 6, 2022
1777709 LabVIEW Palette Items, OpenSSH Exec and PuTTY SSH Exec, Are Not Localized

When you drag a file from the File Explorer to a Path control or constant, the value of the path will have an extraneous NULL character at the end.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2021 SP1 N/A Feb 3, 2022
1783527 LabVIEW Crashes When New VI Object Uses Type Definition for Owner Refnum

LabVIEW crashes when the scripting function New VI Object uses a reference to a type definition for the owner refnum.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 SP1 LabVIEW 2022 Q3 Jul 26, 2022
178494 Packed Library Compatibility Breaks After Implementing Parent Method

When a class uses Call Parent Class Method, but the parent class doesn't implement that method, then adding an implementation to the parent class needlessly requires the child class to recompile. If the classes are in separate packed libraries (PPLs), the child class PPL must be rebuilt.

Workaround:

Fixed in the LabVIEW 2019 SP1 f5 patch.

LabVIEW 2019 SP1 LabVIEW 2019 SP1 f5 Dec 2, 2021
1792822 XY Graph Can Display Incorrect Interpolated Values

When Tools > Options > Environment > General > End text entry with Enter keyis enabled, Ctrl&#43,Enter should add a line feed to a string. However, this keyboard shortcut is adding a new array element, if the string is an element in an array.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2021 LabVIEW 2022 Q3 Jul 26, 2022
181687 Web publishing tool fails without error

The web publishing tool may fail to start the web server if the port is already reserved, yet not return an error.

Workaround:

Ensure that the port to be used by the web server is not in use.

LabVIEW 8.6 N/A 08/03/2009
1836620 Files Larger than 32 KB Are Truncated When Transferred Using LabVIEW SFTP

If you upload a file larger than 32 KB through SFTP, the connection will close immediately and the destination file will be truncated to 32KB.

Workaround:

Set block size to 16 KB in SFTP session property node.

LabVIEW 2021 LabVIEW 2022 Q3 Jun 2, 2022
1847167 LabVIEW Cannot Connect to a Remote Application to Debug

When the "error in" passed to the Python Node contains a warning, the "error out" changes the status boolean to True, which changes the warning to an error.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2021 LabVIEW 2022 Q3 Jul 26, 2022
1855766 Projects That Reference High Resolution Polling Wait VI Report Missing Dependencies Needlessly

The High Resolution Polling Wait VI contains code for multiple platforms. Projects that reference this VI will report missing dependencies, though the missing libraries are for other platforms.

Workaround:

There is currently no known workaround for this issue.

N/A LabVIEW 2022 Q3 Jul 26, 2022
185890 Text on a VI can be mutated to appear as Unicode

After building a project into an executable, various text for controls and indicators changes languages. It appears that the text was interpreted as Unicode.We have not been able to reproduce this in house to find a definite cause. Because of this we will leave this CAR open even though we have created code to recover from the corruption if it happens.Previously tracked as CAR 179683

Workaround:

Upgrade the VI to LabVIEW 2011. In 2011 we put in code to only view text on VIs as unicode if the UseUnicode&#61,True is in the LabVIEW .ini file.

LabVIEW 8.6.1 N/A 07/23/2010
1863309 Python Nodes May Incorrectly Execute Serially

Using multiple Python Nodes without dataflow dependencies causes LabVIEW to serialize their execution, causing the VI to run longer than it should.

Workaround:

Place Python Nodes inside single iteration loops.

LabVIEW 2021 LabVIEW 2023 Q1 N/A
1865552 LabVIEW 2021 SP1 Installation Fails on Some Linux Desktop Systems

LabVIEW 2021 SP1 causes an increase in the memory usage of some applications unnecessarily over time.

Workaround:

You can disable the performance optimization which caused the memory leak by adding "MemoryManger.UseMasterPointerPool &#61, FALSE" to the LabVIEW INI file. LabVIEW 2021 SP1 f1 patch fixes the issue by disabling the performance optimization by default.

LabVIEW 2021 SP1 LabVIEW 2021 SP1 f1 Apr 22, 2022
186808 Shared Variable library on PC is undeployed if the a V in the same project is programmatically deployed to a Real-Time target

When programmatically deploying a VI to a Real-Time target the Shared Variable library residing in the same project as the deployed VI will be undeployed.

Workaround:

Programmatically deploy the shared variable library on the PC after deploying the VI to the real-time controller.

LabVIEW 2009 32-bit N/A 07/20/2011
1887467 LabVIEW Community Edition Does Not Install on "Bullseye" Version of Raspberry Pi OS


Workaround:

There is currently no known workaround for this issue.

LabVIEW 2021 LabVIEW 2022 Q3 Jul 26, 2022
188865 When making multiple calls to Python function in a For Loop, the Python execution treats the passed data as a list, rather than a NumPy array

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2017 SP1 LabVIEW 2020 Apr 20, 2020
188911 Control image alignment incorrect when "new report page" VI is used

When using Append Control Image to Report.vi, the alignment of some images are ignored when New Report Page.vi is used between appended images. This problem only exists with Office 2007. Other versions - Office 2003 and Office 2010 do not exhibit this behavior.

Workaround:

Use a New Report Line.vi between appending the image and the New Page.vi

LabVIEW 2009 32-bit N/A 06/16/2010
1890126 Building Applications with "Exclude Dependent Shared Libraries" Option Does Not Exclude .NET Assemblies

When building an executable or a packed library, the option "Exclude Dependent Shared Libraries" under Properties>>Additional Exclusions excludes C and C&#43,&#43, DLLs but not .NET DLLs.

Workaround:

Register the assembly in the Global Assembly Cache (GAC).

LabVIEW 2021 LabVIEW 2022 Q3 Jul 26, 2022
1920163 LabVIEW Application Using "Enable Enhanced DSC Run-Time Support" Option Crashes

When running an application on a PC connected to a Linux RT system, opening a type definition file from the search results in LabVIEW can cause the application to disconnect from the remote system.

Workaround:

Fixed in the LabVIEW 2021 SP1 f2 Patch.

LabVIEW 2021 | NI Linux RT 21.0 LabVIEW 2021 SP1 f2 Jun 27, 2022
1929608 Subtract Function Erroneously Displays Coercion of Timestamp Inputs

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2021 SP1 LabVIEW 2022 Q3 Jul 26, 2022
196607 DTbl Replace Subset VI behavior change between LabVIEW 8.6.1 and 2009

The start input indexes from the replacement data instead of the existing data

Workaround:

Set the index of data to replace from 0

LabVIEW 2009 32-bit N/A 10/01/2010
198717 Unflatten From XML fails for cluster and arrays that consist of variants

Creating a cluster that contains a variant or building an array of variants, and then trying to flatten it to XML using the Flatten To XML VI and then unflattening it using the Unflatten From XML VI will throw error 1106

Workaround:

N/A

LabVIEW 2009 32-bit N/A 02/01/2010
1993972 LabVIEW Incorrectly Reads WAV Data Saved in DBL Format

Workaround:

Convert DBL values to I16.

LabVIEW 2021 LabVIEW 2023 Q1 N/A
202192 LabVIEW UDP broadcast is inconsistent across different OS's.

If the UDP Open VI has 0.0.0.0 wired to the Net Address terminal, the behavior varies with OS. Windows XP and NI ETS will send on all interfaces, while Windows Vista, Windows 7, VxWorks, and Linux will send on the default interface.

Workaround:

N/a

LabVIEW 8.6.1 N/A 07/24/2012
2051887 LabVIEW Offline Help Is Unavailable on Windows Server 2016

Workaround:

Use the online help from ni.com.

LabVIEW 2022 Q3 | Software Platform Bundle 2022 Q3 LabVIEW 2023 Q1 Jul 27, 2022
2052750 Same Version of LabVIEW Is Listed Twice in Software Section of NI MAX

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2022 Q3 N/A Jul 26, 2022
2057366 Loading a Project Containing RT CompactDAQ Target on LabVIEW 2022 Q3 when LabVIEW RT is Not Installed Crashes LabVIEW

Consider a case where LV 2022 Q3 and DAQmx 22.8 are installed, but not LabVIEW Real-Time. When trying to create a new project andadding an RT CompactDAQ Target to the project, clicking on the newly added target causes LabVIEW to churn for a few seconds and then crash. Steps to reproduce: Install LV 2022 Q3 and DAQmx 22.8. Do not install LabVIEW Real-time. Create a new project Add an RT CompactDAQ Target to the project Click on the newly added Target. LabVIEW will churn away for a bit and then crash.

Workaround:

Install LabVIEW Real-Time on the system and re-open the project

LabVIEW NI-DAQmx 2022 Q3 N/A Aug 2, 2022
2058864 Function That Converts Variant to Flattened String Produces Incorrect String Type for Set Data

Workaround:

Not Applicable

LabVIEW 2019 SP1 LabVIEW 2024 Q1 Jan 22, 2024
2059713 Application Web Service Sometimes Fails to Start

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2021 SP1 LabVIEW 2023 Q3 Jul 20, 2023
2062084 CompactRIO Single Board Controllers with NI-DAQmx Support and Real-Time Scan Resources Will Fail to Compile Bitfiles on LabVIEW 2022 Q3

Compilation failures with timing violations are likely to occur for users with C Series modules under Real-Time Scan Resources.The targets affected aresbRIO-9603,sbRIO-9608,sbRIO-9609,sbRIO-9626,sbRIO-9629,sbRIO-9638.

Workaround:

Use LabVIEW 2021 or earlier for these targets

LabVIEW NI CompactRIO 2022 Q3 N/A Aug 2, 2022
2065508 Using the DAQAssistant with DAQmx 2022 Q3 on LabVIEW 2022 Q3 Fails to Generate Code

Using the DAQAssistant on LabVIEW 2022 Q3 with DAQmx 2022 Q3 installed fails to configure the DAQAssistant node and gives the following code generation error: "LabVIEW Code Generation failed to execute.This may occur if the code gen engine is not properly installed, or if you are using a LabVIEW version under development" . Other workflows that use the DAQ Assistant to generate DAQmx tasks also fail.

Workaround:

Install LabVIEW 2021 SP1LabVIEW 2021 SP1 does not need to be activated, it is sufficient to install LabVIEW 2021 on your system and not activate it Installing just the LabVIEW 2021 SP1 run-time engine will not be sufficient, the LabVIEW ADE needs to be installed

LabVIEW NI-DAQmx 2022 Q3 N/A Aug 2, 2022
208088 Updating the Labels of a Cluster Written to a Chart Does Not Update the Cluster Used for Chart History

Changing the Label of elements in a cluster written to the Waveform Chart does not update the label of the cluster when read from the Waveform Chart Data History Property.

Workaround:

Temporarily wire up a completely different data type to the Waveform chart indicator and then rewire the original cluster. The changes will now propagate to the Chart History.

LabVIEW 2009 32-bit N/A 03/09/2010
2081071 LabVIEW Occasionally Crashes the Running System Exec Call That Produces Error Output

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2022 Q3 N/A Jul 26, 2022
2081644 Some Localized Examples Are Missing in Example Finder

Workaround:

Copy the contents of the localized exbins folders (such asC:\Program Files (x86)

ational Instruments\Shared\Example Finder\1.0\Products\LabVIEW\22.0\exbins\Chinese) into the English folder (C:\Program Files (x86)

ational Instruments\Shared\Example Finder\1.0\Products\LabVIEW\22.0\exbins\English),and delete thelocalized folders.

LabVIEW FPGA Module 2022 Q3 N/A Jul 26, 2022
208364 LabVIEW built installers created on a 32-bit machine will not install most drivers when run on a 64-bit machine

If you build an installer using LabVIEW on a 32-bit machine that contains National Instruments drivers, the corresponding drivers will not be installed if the installer is run on a 64-bit machine. Drivers such as NI-DAQ, NI-Sync etc. are affected by this issue. Installation on 32-bit machines are not affected by this bug.

Workaround:

On the deployment 64-bit machine, download and install the missing drivers from the ni.comDrivers and Updatespage. SeeKnowledgeBase 5A8KPKZL: Why Isn't the NI-DAQmx Runtime Installed on a 64-bit System By My Installer?

LabVIEW 8.5 N/A 02/16/2010
2100578 Find Parallelizable Loops Does Not Open When Invoked from Tools Menu of a VI

Tools > Profile > Find Parallelizable Loops does not work when invoked from the menu of a VI.

Workaround:

Invoke the menu item from the Project Explorer window's menu.

LabVIEW 2021 SP1 | LabVIEW 2022 Q3 LabVIEW 2023 Q1 N/A
2104674 Unable to Install LabVIEW 2022 Q3 on Ubuntu 22.04

A default installation of Ubuntu 22.04 (Jammy Jellyfish) fails to install LabVIEW 2022 Q3 due to missing dependencies such as libncurses5, libldap-2.4-2, and libopenal1. Beginning with version 22.04, these packages are no longer shipped in the Ubuntu distribution. They were included in previous versions of Ubuntu.

Workaround:

From NI Linux Device Drivers 2022 Q4 or later, install ni-hwcfg-utility. It will provide LabVIEW with updated versions of components that do not rely on the missing legacy components.

LabVIEW 2022 Q3 LabVIEW 2023 Q1 Oct 24, 2022
2109080 LabVIEW Cannot Access the Microphone on macOS


Workaround:

Fixed in the LabVIEW 2022 Q3 f1 Patch.

LabVIEW 2022 Q3 LabVIEW 2022 Q3 f1 Patch Sep 28, 2022
213279 Some nodes may crash or yield incorrect/inconsistent results when Inlined

An Inline public methodVI calling a private-scope method VI, inlined into a non-class caller may give a runtime error when trying to call the private method from the inlined code in the non-class caller.

Workaround:

Do not try to Inline VIs with these nodes.

LabVIEW 2010 32-bit N/A 02/19/2010
218083 VIs with errors may show additional errors for code in disabled frames of Conditional Disable Structure

If you have a VI that has errors in it, there may be additional errors shown. The errors will be in code that is inside of a disabled frame of the Conditional Disable Structure (in the "Default" or "Windows" frame when on RT).

Workaround:

Fix the other errors in the VI, and the additional errors should go away.

LabVIEW 2010 N/A 07/23/2010
219819 Center justified tables display improperly when overlapping with the front panel origin

When you add a table control to the front panel so that it overlaps with the vertical origin of the front panel, LabVIEW displays center justified columns off center when you type text. The cells appear to float or move horizontally until aligned with the vertical origin. Formerly tracked as 50061 and 42NAR8SA

Workaround:

Move the table away from the front panel's vertical origin.

LabVIEW 8.0.1 N/A 09/01/2007
221202 System decoration frame bleeds through system checkbox boolean text

In a System Tab Control with a System Decoration frame, the color bleeds through the boolean text of a system checkbox.

Workaround:

Use a normal button control configured as an indicator behind the boolean text, and resize it to match the width of the text.

LabVIEW 2016 N/A May 16, 2019
221253 Bundle by Name function can send wrong pointer into subVI with Call Library Function Node

If a main VI has the output of a Bundle by Name function connected to a subVI, a Call Library Function node within the subVI can receive the wrong pointer from the wired cluster.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2013 SP1 LabVIEW 2020 Aug 7, 2016
2226492 LabVIEW Crashes When Changing the Tabbing Order of Front Panel Controls

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2022 Q3 LabVIEW 2023 Q1 N/A
2252794 Constructor Node Lists .NET Methods Instead of Constructors When Selecting Parameter

Clicking on a Constructor Node parameter to choose a different constructor results in the menu listing methods incorrectly.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2021 SP1 LabVIEW 2023 Q3 Jul 20, 2023
2254316 LabVIEW Python Node Returns Error 1672 When Trying to Return an Array with NumPy Library Version 1.24

With the 1.24 release of NumPy,Python Nodes that return arrays are failing with the error code 1672.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2023 Q1 LabVIEW 2023 Q1 N/A
2262038 File Dialog Does Not Support Some Patterns That Worked in Earlier Versions

The File Dialog no longer works with NULL characters in the Pattern input to present multiple filters.This change in behavior can affect applications that were built with the option "Allow future version of LV Runtime to run the application."

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2022 Q3 N/A Feb 9, 2023
2263807 Activate Button Does Not Work in LabVIEW Evaluation Reminder Dialog


Workaround:

UseHelp>Activate LabVIEW Componentsfrom the LabVIEW menu or run the NI License Manager.

LabVIEW 2023 Q1 LabVIEW 2023 Q3 Feb 9, 2023
226840 Formula VI does not execute pow(x,y) function

Workaround:

Use the formula node to use the pow(x,y) function. If you need to change this programmatically, use the Power of X function in G code.

LabVIEW 2009 32-bit N/A 10/01/2010
227030 Wait on Notification from Multiple function has unexpected behavior when ignoring previous input.

Workaround:

See KB

LabVIEW 8.0 N/A 07/23/2010
227609 Statically linking a LabVIEW built DLL in a C&#43,&#43, project results in error 998 if the DLL is not added to the Delay Loaded DLLs list

Workaround:

Go to the Project Property Pages, Configuration Properties»Linker»Input and add the name of your DLL to the Delay Loaded DLLs list.

LabVIEW 7.1.1 N/A 06/16/2010
229641 Hang can occur when deploying RT project that has not been check out of VSS

When using VSS source code control for a real time project and trying to deploy code that has not been checked off the deployment window blocks a pop up from VSS saying that the code has not been checked out. The deployment status window is modal so it does not allow you to select to proceed in the VSS window.

Workaround:

In the LabVIEW project properties disable the prompts from source code control. Or you could make sure that the VIs are saved prior to deploying.

LabVIEW 2009 32-bit N/A 07/23/2010
232348 Changes to a library item's access scope sometimes do not update broken callers.

Changing a library item's access scope sometimes does not update callers which are broken only because they were attempting to access an item which was out of scope to them.

Workaround:

Force recompile (ctrl&#43,click on the run arrow) any VI which incorrectly believes that access scope forbids access to it's dependency. Changing the access scope to another value, then back to the desired value while the VI is open will also fix the issue.

LabVIEW 2010 32-bit N/A 07/23/2010
233061 LabVIEW crashes after working with Simulation Subsystem using a LabVIEW Class

Sometimes LabVIEW will crash after working with a Simulation Subsystems that has a LabVIEW Class as one of its controls or indicators on its connector pane. Usually it is only a problem when working with the Subsystem's caller within a LabVIEW Project. The crash will occur after closing the project, while returning to the initial LabVIEW window.

Workaround:

Save all work before closing the LabVIEW Project when using LabVIEW Simulation and Classes together.

LabVIEW 2010 32-bit N/A 11/10/2011
2330658 Unexpected Error Occurs When Running Sound VIs on LabVIEW for macOS

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2023 Q1 LabVIEW 2023 Q3 Jul 20, 2023
2331372 LabVIEW Sometimes Crashes When Labels Contain a Mix of Unicode and Non-Unicode Characters

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2022 Q3 LabVIEW 2023 Q3 Jul 20, 2023
2342514 Open Venv Python Session.vi Does Not Work For Paths With Spaces

Open Virtual Environment Session.vi with the Open Venv Python Session configuration returns error 1671 ("Error creating python session") if the Env path contains any spaces.

Workaround:

Create a directory hard symlink viamklink /Jthat does not contain spaces and use that path in LabVIEW.

LabVIEW 2023 Q1 LabVIEW 2023 Q3 May 2, 2023
2345599 Probes for Queues and Sets Sometimes Show Erroneous Data

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2019 SP1 LabVIEW 2023 Q3 Jul 20, 2023
235019 OpenSSL fatal error when LabVIEW exits

The OpenSSL fatal error possibly occurs when using Search features in LabVIEW for the first time after installation.

Workaround:

Launch LabVIEW and exit when Getting Started Window opens. The error now goes away in future launchings.

LabVIEW 2010 32-bit LabVIEW Unknown 08/03/2010
2350519 New Override VIs Do Not Have Parent Icon

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2023 Q1 LabVIEW 2023 Q3 Jul 20, 2023
236193 Crash with invalid input (o or negative values) of "samples per channel" when misusing TDMS Set Channel Information

There are some situations if you set the value of "samples per channel" of TDMS Set Channel Information as 0 or negative values (invalid values), which could cause a crash.

Workaround:

Avoid using 0 or negative values as "samples per channel".

LabVIEW 2010 LabVIEW 2010 CVI 02/18/2011
236377 Dropping XControl from public library breaks XControl

When adding an X control from a public library into the controls palette, it become broken when dropped down to the front panel from the controls palette.

Workaround:

Include a merge VI in the functions palette

LabVIEW 2009 32-bit N/A 10/01/2010
236817 NI-Auth does not work with Firefox

Web Services using NI-Auth work incorrectly in Firefox. A user's log in credentials will never be accepted.

Workaround:

Use Internet Explorer

LabVIEW 2010 32-bit LabVIEW Unknown 08/03/2010
238713 3D Picture Controls can display transparently or crash LabVIEW on certain graphics cards

The 3D Picture Control is built on aOpenSceneGraphwhich uses OpenGL. Several reports of the 3D picture control crashing LabVIEW have been reported. In almost all cases it was an Intel integrated graphics card involved. This crash is caused by an incompatibility of the graphics hardware.Note: Many of the 3D Graphs use the 3D Picture Control

Workaround:

There have been several things that have worked for users:Update the video driverTurn on/off hardware accelerationTurn on Aero in Windows 7Turn off Aero in Windows 7

LabVIEW 2009 32-bit N/A 04/20/2011
2392126 List of Objects in Quick Change Dialog Is Not Localized

Workaround:

Not Applicable

LabVIEW 2023 Q3 LabVIEW 2024 Q1 Jan 22, 2024
239631 Memory Growth with TDMS Write

With the standard TDMS API, when TDMS Write VIs are executed the API will build a cache in memory. This may present as a memory leak, as this memory is only cleared in specific situations.

Workaround:

SeeKnowledgeBase 5WQD51YS: Memory Growth with TDMS Writefor more information.

LabVIEW 2009 N/A 04/27/2012
239719 Property page doesn't update when Adapt to Source is coerced to off

If you have a FXP constant with Adapt to Entered Data set and make any modifications to the display format, the resulting constant will not be set to adapt. The property page will not reflect this change before it is closed.

Workaround:

Always double-check condition of Adapt To Entered Data.

LabVIEW 2010 N/A 08/03/2012
2398515 Error 56 Occurs When Using SFTP VIs with Password Authentication on Windows 11

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2023 Q1 LabVIEW 2023 Q3 Jul 20, 2023
2407732 Table Control Does Not Respond Correctly to Touchpad Scroll Gestures

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2022 Q3 LabVIEW 2023 Q3 Jul 20, 2023
243468 Default Namespaces not supported in XML Parsing VIs

When trying to work with XML Parsing VIs you will get error -2768Possible reason(s):LabVIEW: The XPath expression does not conform to XPath syntax. Refer to the W3CXPath Web site at http://www.w3.org/TR/xpath for more information about XPath syntax.

Workaround:

Remove the default namespace (example: remove xmlns&#61,"http://www.ieee.org/ATML/2007/TestResults"),

LabVIEW 2010 32-bit N/A 08/17/2010
2440992 Using the Right-Click Menu Plugin to Lookup All Shortcut Menu Tags and Types Does Not Display Expected Results

Workaround:

Not Applicable

LabVIEW 2020 LabVIEW 2024 Q1 Jan 22, 2024
244551 Editing large strict type definitions can take a long time to update

When large type definitions are updated, all instances in memory require an update. This update can take many minutes for very large type definitions.

Workaround:

Use smaller type definitions, or consider using LabVIEW classes to contain your type data.

LabVIEW 7.1.1 N/A 07/23/2012
245148 Class Properties dialog sometimes throws timeout error 123 when opening and must be restarted

In LV 2010, there appears to be a timing race condition in the Class Properties dialog for LabVIEW classes. Every once in a while if you try to launch the dialog, the dialog will throw an error dialog reporting error 123 that the dialog has timed out while trying to launch. After you dismiss the dialog, you may see a secondary error dialog. Once you dismiss that, you can relaunch the Class Properties dialog and will generally succeed. There is no danger to your class and no corruption to you class file has occurred. It is solely a bug in trying to launch the dialog.

Workaround:

Hit Continue or OK button to dismiss all error dialogs that come up then retry opening the Class Properties dialog.

LabVIEW 2010 32-bit N/A 02/18/2011
245359 Selecting a newer version of a .NET assembly does not reload assembly

Changing a constructor from an old version of a .NET assembly to a newer version at edit time does not cause the new assembly to be loaded and consequently none of the new functionality is available.

Workaround:

1. Remove the old assembly so the .NET Runtime is not able to find it. It will then return the updated version to LabVIEW.2. Load the new assembly in a blank VI before opening your existing VI. This will load the new version into memory prior to you requesting the older version.

LabVIEW 2010 32-bit N/A 08/03/2012
2461486 Error While Upgrading SystemLink Server or LabVIEW 2023 Q1 to 2023 Q3 because of SystemLink Message Broker
Users upgrading to SystemLink Server 2023 Q3 (23.5) or LabVIEW 2023 Q3 (23.3) will encounter an installation error due to an issue upgrading the ni-systemlink-message-broker package, if they've previously installed SystemLink Server 20.0 or LabVIEW 2020 (RabbitMQ 3.8.2), then updated to 21.x or 22.x version of SystemLink Server or LabVIEW, before updating to SystemLink Server 2023 Q3 (23.5) or LabVIEW 2023 Q3 (23.3).   

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2022 Q3 LabVIEW 2023 Q3 Feb 9, 2023
2479826 Control Can Have Unexpected Default Value When Created Using Double Click During Wiring

When you create a control by double-clicking when wiring from a subVI terminal , the control can have a default value that is different from the displayed value.

Workaround:

Not Applicable

LabVIEW 2023 Q3 LabVIEW 2024 Q1 Jan 22, 2024
2481419 Incorrect Value Returned When Reading Class Name Property of Some Event Structure Terminals

Using VI Scripting, reading the Class Name property of the Dynamic Terminal or Timeout Terminal of an Event Structure returns "Generic" instead of "Tunnel."

Workaround:

Not Applicable

LabVIEW 2020 SP1 LabVIEW 2024 Q1 Jan 22, 2024
248421 Bitshift does not work correctly in Expression Nodes and Formula Nodes with a data type smaller than I32

Workaround:

N/A

LabVIEW 8.5.1 N/A 10/29/2010
248914 Changing the order of controls or deleting controls in a type def cluster can change references

When you create a reference for a control in a type defined cluster LabVIEW uses the cluster order to determine what control the reference is referring to. Say you have a type defined cluster with elements A, B, C and D with cluster order 1,2,3 and 4 respectively. On the block diagram of a VI you have control references to each of the controls. If you open the type def and delete control C the block diagram of the VI will only contain 3 references. Moreover, the reference that used to be for control C will now reference control D. This is because the control is based on cluster order

Workaround:

N/A

LabVIEW 7.1.1 N/A 10/01/2010
250588 Warning Generated in a Method or Property of an XControl Appears as an Error in the Top Level VI

If you create a method or a property in an Xcontrol in which you have implemented code to generate a warning it is transformed into an error in the calling VI.

Workaround:

In the VI look for specific error and transform back to a warning

LabVIEW 8.5.1 N/A 11/02/2010
251105 S&amp,V XControls built as Remote Panel crashes LabVIEW.

Remote panels do not reliably support the Sound and Vibration XControls.

Workaround:

Use another mechanism for remote viewing.

LabVIEW 2009 32-bit N/A 02/18/2011
2516141 64-bit Values Incorrectly Converted to 32-bit in Expression Node

Workaround:

Not Applicable

LabVIEW 2021 LabVIEW 2024 Q1 Jan 22, 2024
2519019 Built Application Searches for NI_Matrix.lvlib:RealMatrix.ctl When Run

When you run an application built with the matrix datatype, the application searches for NI_Matrix.lvlib:RealMatrix.ctl.

Workaround:

Not Applicable

LabVIEW 2023 Q3 LabVIEW 2024 Q1 Jan 22, 2024
2519561 Distributed System Manager Does Not Open When Called from the Tools Menu in LabVIEW

Workaround:

Fixed in LabVIEW 2023 Q3 Patch 2.

LabVIEW 2023 Q3 LabVIEW 2023 Q3 Patch 2 Jan 10, 2024
2543964 Shared Variable Properties Dialog Is Missing Some Options

The Shared Variable Properties Dialog Box lacks the following categories provided by the LabVIEW Real-Time and LabVIEW Datalogging and Supervisory Control modules: RT FIFO, Alarming, Update Deadband, Initial Value, Logging, and Security.

Workaround:

Fixed in LabVIEW 2023 Q3 Patch 2.

LabVIEW 2023 Q3 LabVIEW 2023 Q3 Patch 2 Jan 10, 2024
2552750 Incorrect Wiring After Inserting Some Functions On Set and Map Wires with Quick Drop

After inserting a Remove From Set or Remove From Map function using Quick Drop, the output wire is not connected to the correct terminal.

Workaround:

Not Applicable

LabVIEW 2020 LabVIEW 2024 Q1 Jan 22, 2024
255466 Shared variable moved from a project directly to a tab control is not added to the active page.

Workaround:

After dragging the variable to the tab control. Reselect it and drag it slightly until the dotted lines appear around the tab control page and then drop it. The shadow is then removed because the variable has been added to the active page.

LabVIEW 2010 32-bit N/A 12/15/2010
2558611 Some Parts of a VI Diagram Do Not Execute in Parallel

In rare cases, some parts of VI diagrams do not execute in parallel when the same code had done so in earlier versions of LabVIEW.

Workaround:

Fixed in LabVIEW 2023 Q3 Patch 2.

LabVIEW 2019 LabVIEW 2023 Q3 Patch 2 Jan 10, 2024
2561077 LabVIEW Crashes When Importing a Shared Library

LabVIEW crashes when using the Import Shared Library tool to import a DLL.

Workaround:

Fixed in LabVIEW 2023 Q3 Patch 2.

LabVIEW 2023 Q3 LabVIEW 2023 Q3 Patch 2 Jan 10, 2024
256141 Windows 7 often shows "(Not Responding)" and will bring other windows to the front during expensive operations

If Windows 7 if a window is unresponsive to user input (e.g. mouse clicks) for five seconds it will ghost the window and display "(Not Responding)".Some operations in LabVIEW run in the UI thread. This is to prevent different operations from happening in parallel (e.g. compiling, edit operations, saving, drawing, etc.). Because large block diagrams can take longer than five seconds to compile or run clean up on Windows can tag LabVIEW as Not Responding.In some cases the ghosted window can move behind the other open windows when it finishes it task.

Workaround:

Wait until the expensive task as finished before trying to interact with the window.

LabVIEW 2009 32-bit N/A 10/28/2010
2565540 Sort 2D Array.vim is Unexpectedly Slow When Operating on a Sorted Array

Workaround:

Not Applicable

LabVIEW 2020 SP1 LabVIEW 2024 Q1 Jan 22, 2024
257194 Connector pane of a VI can change from LabVIEW 2009 to LabVIEW 2011

If you have a VI with no items in the connector pane and upgrade it straight form LabVIEW 2009 to LabVIEW 2011 then the connector pane may change

Workaround:

Open in LabVIEW 2010 first

LabVIEW 2011 32-bit N/A 08/02/2011
257275 Format Into String does not work with the %d format for numbers larger than I32

The Format Into String VI does not correctly format numbers outside the 32-bit integer (I32) range when using the '%d' format. When the number is outside the I32 range, the resulting string displays either -2147483648 or 2147483647 depending on if the number is negative or positive.

Workaround:

Use %.0f instead of %d as the format string.

LabVIEW 2010 32-bit LabVIEW 2015 12/31/2010
257735 Class VIs that call shared variables in a library in an auto-populating folder will not be loaded

If a VI in a class calls a shared variable that is in a library in an auto-populating folder, it will not find the shared variable when the project is loaded

Workaround:

Make the folder a snapshot instead of auto-populating and reopen the project

LabVIEW 8.6.1 N/A 02/01/2013
2599334 WebDAV, HTTP, and SMTP Functions Fail to Use Certificates from Files

Configure SSL (WebDAV), Asynchronous Configure SSL (WebDAV), ConfigSSL (HTTP Client), and Config TLS (SMTP) functions fail to use certificate files but do not return errors.

Workaround:

Copy any needed certificates into the Windows certificate store.

LabVIEW 2023 Q1 LabVIEW 2024 Q3 Jan 22, 2024
2625975 LabVIEW Crashes After Clicking the Help Button in Application Properties

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2024 Q1 LabVIEW 2024 Q1 Patch 1 Jan 22, 2024
275961 Silver style Thermometer frame doesn't resize correctly when control is resized.

Workaround:

N/A

LabVIEW 2011 32-bit N/A 03/08/2011
278730 Web Services ignore the No App switch on RT targets

After deploying the web service to a RT target, it become like a start up executable. Any time the target is reboot, the web services re-starts automatically. However, unlike with start up executables, the web service can't be turned off by the No App switch.

Workaround:

N/A

LabVIEW 2011 32-bit LabVIEW 2015 02/10/2011
279373 SMTP has been updated to use port 587, LabVIEW makes use of legacy port 25

The SMTP has been updated to use port 587 instead of port 25. LabVIEW still makes use of port 25 with its SMTP VIs.

Workaround:

Open any SMTP VI, and find the SMTP_CreateSession.vi. Open that VI, you will find a numeric constant on the block diagram that is set to 25.

LabVIEW 2010 32-bit N/A 08/02/2011
282737 Applications with Chinese characters in the executable name will throw fatal error on English Windows 7

Workaround:

Use a different name for the executable.

LabVIEW 2010 32-bit N/A 08/02/2011
284289 Source distributions with block diagrams removed prevents the use of static Shared Variable nodes.

Source distributions that include static Shared Variable nodes with block diagrams removed will return the following error at run-time, "VI has a bad connection to or cannot find a subVI or external routine."

Workaround:

Use theProgrammatic Shared Variable APIor do not remove the block diagrams.

LabVIEW 2010 32-bit N/A 07/20/2011
284936 Breaking one Override VI in LVOOP shows all siblings as broken but does not explain why

When using OOP in LabVIEW, breaking the connector pane of a child class Override VI will make all of its sibling override VI's appear broken even though they are not broken. Hitting run on the broken Run Arrow of any child class Override VI will list all of the child class VIs in the list of "Items with Errors", but none of them will have an error associated with it except for the broken ones.

Workaround:

Use the red X in the errors window to find the actual broken VI

LabVIEW 8.6.1 N/A 04/20/2011
289842 Get Variant Attribute VI returns wrong value if attribute not found

The default value that's returned by the Get Variant Attribute VI is not blank when nothing is wired to the default value terminal. The Get Variant Attribute instead seems to return the last/previous value it returned as the default value.

Workaround:

Use the Found? output and logic to return a blank variant if necessary

LabVIEW 8.6.1 N/A 03/21/2011
290105 Text Labels in Silver Control are not in silver style

Workaround:

N/A

LabVIEW 2011 32-bit N/A 04/05/2011
294285 Type Defined Shared Variable not found in Executable

When a VI is made with the following conditions:1) Uses a Shared Variable attached to a type definition2) The type defined control (attached to the shared variable) is not in the main project directory (ie, it is in a different folder)3) The VI uses dynamic data (or waveform to dynamic data function)A created executable seems to not include the *.ctl file defining the shared variable type. This missing type definition causes the run time engine, when starting the executable, to search for and (if the control is not located in the searched directories) fail to find the *.ctl file. If the location of the *.ctl file is specified, the executable runs without issues.

Workaround:

Disconnect from Type Def during the build.

LabVIEW 2010 32-bit N/A 08/02/2011
305978 Save As Duplicate with Include All Dependencies makes a Copy of the instr.lib Folder.

Include All Dependencies option in Save As does not ignore files from laview\instr.lib folder.

Workaround:

Choose "Select contents to copy" and uncheck instr.lib

LabVIEW 2010 32-bit N/A 08/02/2013
314082 Listbox Control With Transparent Cell Background Does not Grey Disabled Item

n/a

Workaround:

Make the background color of the cells match the background of the panel, instead of making them transparent.

LabVIEW 2011 32-bit N/A 09/07/2011
316372 Newly created typedefs are not automatically added to library

When creating a subVI from a VI contained within a library, the subVI is added to the caller VI's library. When creating a typedef from a control in the same VI, the typedef is not added to the library.

Workaround:

Manually add the typedef to the library.

LabVIEW 2010 32-bit N/A Feb 17, 2020
316382 When using a LabVIEW-built .NET Interop Assembly in an ASP .NET application, the first call to the assembly will return a NullReferenceException

Workaround:

The exception only occurs on the first call to the assembly, so using a try-catch block to handle the exception will allow subsequent calls to behave normally.

LabVIEW 2015 SP1 LabVIEW 2021 Feb 14, 2020
316578 Aborting a VI can leave VIs targeted by a Call By Reference node reserved permanently

Workaround:

Close the project to unreserve the VI

LabVIEW 2013 LabVIEW 2020 Feb 18, 2020
316598 Mass Compile causes LabVIEW crash

LabVIEW 2018 64-bit crashes during Mass Compile if Vision VIs are included, but the Vision Development Module is not installed.

Workaround:

Install the Vision dependencies that are required.

LabVIEW 2018 N/A Aug 13, 2018
316619 .NET Constructor Node cannot differentiate between functions with different enums at the same position

Workaround:

Create a wrapper assembly to call from LabVIEW

LabVIEW 2014 N/A Jun 16, 2015
317117 3D Surface Graph incorrectly blends colors when interpolating

In certain situations when viewing a projection onto a 2D plane, the 3D Surface Graph can incorrectly blend colors instead of displaying them in a straight line.

Workaround:

N/A

LabVIEW 2011 32-bit N/A 05/22/2017
317596 Cannot Scroll Array Indicator with Mouse Wheel in Running VI

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2017 LabVIEW 2023 Q1 N/A
320200 EXE including 'Std Deviation and Variance' VI is unloadable

Building an executable including a VI that uses the 'Std Deviation and Variance' VI results in an error: "(Hex 0x464) VI is not loadable".

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2018 LabVIEW 2020 N/A
320485 User Events Created from Objects Cause Broken Packed Library VIs

If you are using an object as a user event, it works fine while in the LabVIEW environment. However, when compiled into a packed library, the user event refnum has a broken wire.

Workaround:

N/A

LabVIEW 2010 SP1 32-bit N/A 08/02/2011
322914 Formula VI does not execute pow(x,y) function

Workaround:

Use the formula node to use the pow(x,y) function. If you need to change this programmatically, use the Power of X function in G code.

LabVIEW 2009 32-bit N/A 10/01/2010
335576 Play Waveform Express VI gives error 4803 with Sample Rate 3125, 6250, 12.5K, 25K, 50K, 100K, 200K Hz

n/a

Workaround:

Instead of using the "Play Waveform" Express VI, use the code from the example Generate Sound.vi.

LabVIEW 2010 SP1 32-bit N/A 08/03/2012
339230 Newly created typedefs are not automatically added to library

When creating a subVI from a VI contained within a library, the subVI is added to the caller VI's library. When creating a typedef from a control in the same VI, the typedef is not added to the library.

Workaround:

Manually add the typedef to the library.

LabVIEW 2010 32-bit N/A 03/05/2018
347272 Executables built (without SSE2) in LV 2011 on an Intel Core Duo machine throw Error 57 when run on a machine with an AMD Athlon 3200&#43, processor.

n/a

Workaround:

Build the executable on the Athlon 3200&#43, computer.

LabVIEW 2011 32-bit N/A 08/03/2012
351506 [Mac] Test Device option on Play Waveform Express VI Configuration page doesn't output test tone

N/A

Workaround:

N/A

LabVIEW 2011 32-bit N/A 05/07/2012
351741 Panes 'Top' pixel coordinates will vary when Windows 'Aero' is enabled/disabled

If the Windows Vista/7 option to "Use visual styles on windows and buttons" is enabled, a VI property node for Front Panel Window:Panel Bounds will return a different 'Top' value.

Workaround:

If you are calculating the position of elements within your VI based on this value, check the deployed OS, and subtract an offset value.

LabVIEW 2011 32-bit N/A 05/07/2012
353261 Conditional Indexing Terminal on Parallel For Loop with Shift Registers Runs with "Memory is Full Error"

Workaround:

Use the Build Array in a Case structure

LabVIEW 2012 32-bit N/A 08/03/2012
355840 "Get Image" method is unreliable on .NET controls in LabVIEW (64-bit)

Calling the 'Get Image' method on a .NET control works correctly on 32-bit versions of LabVIEW, but will fail to return an image intermittently when LabVIEW (64-bit).

Workaround:

n/a

LabVIEW 2011 64-bit N/A 08/03/2012
356420 Robotics Wizard cannot load a manifest file in a folder with a Chinese character in the name

Robotics Wizard cannot load a manifest file in a folder with a Chinese character in the name

Workaround:

Move the manifest file to a new location

LabVIEW 2012 N/A 07/13/2012
356656 Crash when compiling VIs that call into a certain class based VI hierarchies

Some VIs that call into a formerly non-dynamic dispatch member of a class whose parent is missing may crash when saved or mass compiled.

Workaround:

Open the class first, then open the VI and save it.

LabVIEW 2011 32-bit N/A 08/03/2012
357785 Mouse cursor does not scale properly on a 4k monitor

The mouse size shrinks when entering the block diagram or front panel when using a 4K monitor but is the correct size on the menu bar.

Workaround:

Set the display settings to 100% scaling and 1080p resolution.

LabVIEW 2019 N/A Jan 6, 2021
359662 Some dotted scripting property calls can crash LabVIEW if earlier properties error

If you access the property LinkedControl.ClassName on an object that does not have a linked control error 1308 will be thrown. If you access the property 3 times, LabVIEW will crash.

Workaround:

Separate into two calls, e.g. change a property of LinkedControl.ClassName into a call to LinkedControl, which emits a reference and, if successful, wire that to a second property node to get ClassName.

LabVIEW 2010 SP1 32-bit N/A 07/11/2012
361311 "Natural log of 1 &#43, x" primitive incorrectly returns NaN for small positive values

n/a

Workaround:

n/a

LabVIEW 2011 32-bit LabVIEW 2015 08/03/2012
364338 "Error while retrieving database: Forbidden" connecting to a RT target via the web configuration.

If you change the admin password for an RT target and reboot the target before saving, you may receive the error "Error while retrieving database: Forbidden."

Workaround:

Refresh the web page hosting the web configuration.

LabVIEW 2012 N/A 08/03/2012
364845 Streaming data to a Digital Display Chart data occasionally incorrectly displays zero even when the data is non-zero

N/A

Workaround:

N/A

LabVIEW 2012 N/A 01/29/2013
367249 It is not possible to customize the Run-Time Shortcut menu of a 3D Graph

N/A

Workaround:

N/A

LabVIEW 2012 N/A 01/29/2013
369142 Front Panels may stop updating with 3&#43, monitors with Windows Aero enabled

With Windows Aero enabled on a machine with 3 or more monitors the front panel may stop drawing. This issue has been seen in limited cases and is usually after hours of operation. The application itself continues to run. Moving or minimizing the window causes it to start updating again.

Workaround:

Disable Windows Aero by selecting a non-Aero theme.

LabVIEW 2010 SP1 N/A 09/01/2012
377385 Error 1390 on Dynamic VI Call to Friend Library

The error is returned when two Community scoped LabVIEW Libraries are Friends to each other, and one Library performs a dynamic call to a VI in the other Library.

Workaround:

Change the dynamic call to a static call, or change the scope to Public on the Library containing the callee VI.

LabVIEW 2012 N/A 01/28/2013
381128 The MonthCalendar .NET control automatically resizes to the incorrect size when the VI is run

N/A

Workaround:

At the beginning of the code write to the Container Bounds property node "ContBounds" for the .NET container. While the code is running the calendar will have the right size

LabVIEW 2012 N/A 02/01/2013
381656 Adding or subtracting timestamps causes a conversion to double and precision loss

N/A

Workaround:

Cast the timestamps to clusters of U64 'seconds since epoch' and I64 'fractions of a second' before the operation and then cast back to timestamp after the operation

LabVIEW 2011 N/A 01/29/2013
384591 A password protected VI accessing a password protected community scoped VI is broken if the VIs are set to separate compiled code from source code

This only happens if the VI source-only option set to true: Tools -> Options -> Environment Settings -> Separate Compiled Code from New Files set to true, or via the VI Properties window

Workaround:

Do not separate the compiled code from the source code or remove the password

LabVIEW 2011 SP1 N/A 05/09/2014
388446 Eval Parsed Formula Node.vi returns incorrect results

Incorrect results are possible if preceding Parse Formula Node.vi contains too many C-style comments.

Workaround:

Reduce the amount of comments used in formula input to Parse Formula Node.vi

LabVIEW 2012 N/A 08/02/2013
389041 Error -314250 from Create Network Stream Writer Endpoint

Error is returned when data type is set with a SGL value that has a unit label defined.

Workaround:

Change representation or DBL, or remove the unit label.

LabVIEW 2013 N/A 08/02/2013
390021 An inlined VI can not be placed on the block diagram of a VI with subroutine priority unless it also has subroutine priority

Inlined VIs should ignore the Priority setting in VI properties, however an inlined VI dropped in a subroutine priority VI will break the run arrow unless the inlined VI is also set to subroutine priority.

Workaround:

Set the inlined subVI to subroutine priority

LabVIEW 2012 N/A 03/11/2014
391455 Applying an icon to LabVIEW class overwrites the icons of its methods

The icon for a LabVIEW class appears to be only the banner, but when it is applied it overwrites the entire icon of the method VIs

Workaround:

N/A

LabVIEW 2012 N/A 08/02/2013
39161 The device ID input of the Play Sound File VI does not work on Windows

On Windows, LabVIEW ignores the device ID input of the Play Sound File VI. This VI plays sound only on the default sound card.

Workaround:

Use the Sound Output Configure VI and the Sound Output Write VI with the Sound File Open VI and the Sound File Read VI or the Sound File Simple Read VI. Refer to the Sound File to Sound Output example VI for an example of this workaround.

LabVIEW 8.0.1 N/A 09/01/2007
391784 Memory Lead when Sound VIs are Called Dynamically

Sound Input Configure.vi and Sound Input Clear.vi leak memory when called dynamically

Workaround:

Use a static call to these VIs.

LabVIEW 2012 N/A 08/02/2013
392232 Autopreallocate Arrays and Strings VI Property Can Crash LabVIEW when not in FPGA Context

Changing an FPGA VI to run in a context other than FPGA does turn off the VI property to Autopreallocate arrays and strings if it was previously turned on. Running a VI that has this property on and manipulates arrays or strings can cause LabVIEW to crash.

Workaround:

Uncheck the Autopreallocate arrays and strings VI property for the VI.

LabVIEW 2010 LabVIEW 2015 08/02/2013
392446 Installing LabVIEW on a Windows Laptop Decreases Battery Life

Even with NI applications closed, services installed by LabVIEW request high resolution timers. These timers prevent the hardware from sleeping, and requires more power.

Workaround:

N/A

LabVIEW 2012 SP1 LabVIEW 2015 08/02/2013
392545 Timed Loop crashes LabVIEW after exiting

A timed loop that meets these criteria can crash LabVIEW after finishing execution.1) The Timed Loop must write to the "Offset" input node inside the loop2) The Timed Loop must have set the "Mode" input node to anything else other than "No Change" or "Discard missed periods, ignore original phase" before the loop begins

Workaround:

Configure the Timed Loop once at the beginning of execution instead of each iteration.

LabVIEW 2012 N/A 08/02/2013
394454 Data Binding: Path property can change bindings in other VI clones

Writing to a Data Binding: Path can change binding path for other instances of the control if clones of the VI are already open

Workaround:

Use programmatic Shared Variable access to update front panel controls instead of Data Binding.

LabVIEW 2012 SP1 N/A 08/02/2013
398998 3D Surface Axis Labes not Visible when Dialog Font Changed

Some fonts cause the Axis Labels to be visible on 3D Surface controls when the Dialog Font is changed from default. For example MS Sans Serif causes the issue.

Workaround:

Use a Dialog font that doesn't cause the issue.

LabVIEW 2012 N/A 08/02/2013
399068 Double Numeric Slide can not be Set to 0 when it has Defined Limits with Mouse

A user can not slide a Double Numeric Slide to 0 when it has defined increment, maximum, and minimum properties. Instead of 0, a value very close to 0 will be entered ie: 5.55112E-16.

Workaround:

Do not set both defined maximum and minimum for the slide. Instead, change one of them to Inf or -Inf. Also a value of 0 can be entered into the digital slide.

LabVIEW 2012 N/A 08/02/2013
400736 Error -4403 returned from Write Palette.vi for Template VIs

Template VIs can not be added to the palettes with the Write Palette.vi, error -4403 will be returned.

Workaround:

Add Template VIs to the palettes manually through Tools»Advanced»Edit Palette Set...

LabVIEW 2013 LabVIEW 2015 08/02/2013
401078 Opening any non-VI dialog, such browse for files or one button dialog, may block web service requests from executing.

The most common form of this issue seen when Show Method URL Dialog Box blocks requests to a LabVIEW Web Service. This only affects LabVIEW web services deployed to the debug server or embedded in a LabVIEW executable.

Workaround:

Close the dialog box to allow requests to continue

LabVIEW 2013 N/A 12/01/2014
401421 Updates to Global Variables Not Visible when Remote Debugging a LabVIEW Built Stand-Alone Application

If the updates occured before connecting to the Remote Application with the debugger, the updates won't be visible. Updates to the Global Variable after connection with the debugger is establish will be visible.

Workaround:

Change the build specification for the stand-alone application to wait for debugger on launch, so no Global Variable updates can happen until a debug session is started.

LabVIEW 2012 SP1 N/A 08/02/2013
401689 Constrained Non-Linear Optimization VI has Potential for Infinite Loop

Depending on the function data, Constrained Non-Linear Optimization can execute indefinitely. No checks are done in subVI for infinite loop.

Workaround:

Enter in your own check to see infinite loop is occurring.

LabVIEW 2012 SP1 LabVIEW 2015 08/02/2013
403182 Sound Output.vi Does Not Support more than 2 Audio Channels on Windows 7

Error 4811: "can not support sound format" will be returned from the VI when executed on Windows 7.

Workaround:

More than 2 Channels are supported on Windows XP.

LabVIEW 2012 SP1 N/A 08/02/2013
403727 Repeated Dynamic Calls to VI in Packed Project Library Can Cause Error in VI Call

After over a million Dynamic Calls to a VI contained in a Packed Project Library, a error can be thrown that LabVIEW attempted a recursive call.

Workaround:

The error does not occur on regular project libraries.

LabVIEW 2011 SP1 N/A 08/02/2013
405271 Boolean Mechanical Actions Don't Work as Expected on Windows 8 Touch Screen

Switch Until Released and Latch Until Released don't behave as expected for touch and hold gesture. Boolean controls will not toggle on touch and hold gesture, until finger is dragged outside the bounds of the control. Other Boolean mechanical actions behave as expected.

Workaround:

N/A

LabVIEW 2012 N/A 08/02/2013
406311 VI.Control Value.Set will Crash LabVIEW When Value Non-Variant Data is Used for Value Parameter

The crash will happen when VI.Control Value.Set is invoked upon a VI reference that has been opened by Open VI Reference.

Workaround:

Cast data to variant before wiring to Value parameter.

LabVIEW 2012 N/A 08/02/2013
407614 Control.Delete Method Crashes LabVIEW When Used on Grouped Pictures and Free Labels

LabVIEW will crash when VI scripting method Control.Delete is invoked on pictures or Free Labels that are grouped on the front panel.

Workaround:

N/A

LabVIEW 2012 SP1 N/A 08/02/2013
407633 Set Cell Value Method Returns Error 1604

Set Cell Value method for tables returns error 1604 if method executes at the same time that a user changes the value of a Picture Ring Control.

Workaround:

Architect code so table is not updating continuously to reduce risk that user changes Picture Ring value at the same time that Set Cell Value is executing.

LabVIEW 2012 SP1 N/A 08/02/2013
408391 Non-printable Characters in the Description of Will Corrupt LabVIEW Classes and Libraries

Non-printable characters can be inserted into the description of LabVIEW Classes and Libraries with the Description Property Node. This will corrupt the .lvclass or .lvlib file.

Workaround:

The .lvclass or .lvlib file can be opened in a text editor, and the description can be manually deleted to recover the files.

LabVIEW 2012 N/A 08/02/2013
408790 Palette Editor Cannot Add LabVIEW Classes

LabVIEW Classes are an available option to be added to palettes, but adding them will not take effect.

Workaround:

If your goal is to allow dropping of the class control or constant, you can create a custom control (not a typedef) that has the class on it's panel and add the custom control to the palettes. If your goal is to add the LabVIEW Class as a linked library, you can do so programmatically with Write Palette.vi.

LabVIEW 2009 N/A 08/02/2013
408891 Getting an Entire Column of Data from a 2D Array in the MATLAB® Script Node Returns Only 1 Element

In the context of the MATLAB® Script Node, attempting to return an entire column of data from an array using a command like "column1 &#61, array2D(:,1)," returns only a single element. This same operation on a row "row1 &#61, array2D(1,:)," , returns the entire row successfully.

Workaround:

Transpose the array, and get the data in it's context as a row.

LabVIEW 2012 N/A 10/16/2013
410360 LabVIEW Classes Become Corrupt When Multiple Files With Same File Name are Added to the Class

When a LabVIEW Class is saved with multiple files sub-files that have the same file name, the .lvclass file will become corrupt.

Workaround:

N/A

LabVIEW 2012 SP1 N/A 08/02/2013
410479 Grouping ActiveX containers removes inserted ActiveX objects

When populated ActiveX containers are grouped with other front panel objects, the inserted ActiveX object will be removed.

Workaround:

Re-insert the ActiveX object after it has been grouped with another object, or group a blank ActiveX container, then insert the object.

LabVIEW 2012 SP1 N/A 08/02/2013
410904 Print.VI to Printer Method Always Prints Header in LabVIEW Built Applications

The Page Headers? parameter for Print.VI to Printer is always true when running as a LabVIEW Built Application. The parameter is used properly when the method is ran in the LabVIEW development environment.

Workaround:

1. Select Operate»Print at Completion to print the front panel of a VI when it finishes running.2. Select File»VI Properties.3. Select Print Options from the Category pull-down menu.4. Place a checkmark in the Automatically Print Panel Every Time VI Completes Execution checkbox.5. Uncheck Print header (name,date,page number) box6. Click the OK button.

LabVIEW 2012 SP1 N/A 08/02/2013
412979 Flatten to XML String does not properly escape single and double apostrophes in a string input (' and ")

These should be escaped to "apos" and "quot" but are not. Other special characters including &amp,,&lt,, and > are correctly escaped.

Workaround:

Parse the string manually for apostrophes to escape them

LabVIEW 2012 SP1 N/A 10/17/2013
415924 Double precision numeric constants set to "bar" units sometimes use Pa units

Double precision numeric controls and indicators using "bar" units work correctly, but block diagram constants use Pa instead of bar.

Workaround:

Create the constant from a control with "bar" units and then change the unit label from Pa to bar to get a constant that uses bar.

LabVIEW 2012 SP1 N/A 10/14/2013
420582 Typing Obtain in Quick Drop populates with an unexpected selection

Workaround:

Disable 'relevancy-based search' in the Quick Drop configuration options

LabVIEW 2013 N/A 07/31/2014
420965 Adding a tooltip for a tab control after configuring the tab to show text and image can cause the tooltip to appear in the wrong position

If you configure a tab control for text-image content, and then add an image and change the tooltip, the tooltip will appear far away from the tab control.

Workaround:

View the tooltip after adding the image and before changing the default tooltip

LabVIEW 2012 SP1 N/A 10/14/2013
422507 Entering an integer into a numeric control that has a time display format does not update the control

Double clicking inside a time display numeric control and typing a new value does not update to the new value, and the control reverts to its original value. This happens for controls with a display format of either %t or the default Relative Time format.

Workaround:

If the display format is %t, enter values with a decimal point after the number (as a double)If the display format is the default Relative Time, single click on the hour or minute fields and update individually or enter the value in the format HH:MM with the colon to successfully update

LabVIEW 2013 N/A 10/23/2013
424089 The advanced analysis Kummer Function returns 'NaN' instead of correct values for certain combinations of input parameters.

Check the following forum for more information and a possible workaround

Workaround:

Check the following forum for more information and a possible workaround:http://forums.ni.com/t5/LabVIEW/Bug-in-the-Kummer-Function/m-p/2387522#U2387522

LabVIEW 2013 LabVIEW 2015 05/09/2014
424382 Path controls in LabVIEW for Mac OS X treat .app files as folders instead of files

Workaround:

None

LabVIEW 2013 N/A 10/16/2013
425313 Selecting the option to hide grid lines when using Export Simplified Image with a waveform graph will not hide all grid lines when using multiple axis

When using the waveform graph right-click option to Export Simplified Image with the option to hide grid lines, some of the grid lines will still be visible if there are multiple axis

Workaround:

Disable the grid of the additional axis through the scale tab of the graph properties

LabVIEW 2013 N/A 03/11/2014
425562 Scan from String requires a space between modifiers when using SI notation

Scan from String requires a space between the modifier and the unit. For example, %pV will throw an error with an input string of 10mV, but it works correctly with %p V and an input string of 10m V.

Workaround:

Add an additional space after the modifier

LabVIEW 2012 LabVIEW 2015 10/16/2013
426157 VI invoke node Find CtrlWitkKeyFocus don't work with typdefs

Workaround:

None

LabVIEW 2013 LabVIEW 2015 02/09/2016
428515 On Scientific Linux 6.3 with updated Mesa Drivers, 3D Picture Controls display an inverted image

Workaround:

Downgrade the Mesa drivers or manually invert the image.If your 3rd-Party Mesa driver version is between 7.11 and 9.2.1, you need to add the LabVIEW INI token "Invert3DPictImage&#61,True". Driver version 7.11 and earlier, and version 9.2.1 and later, do not need the INI token.

LabVIEW 2013 N/A 10/23/2013
428914 The Y-Axis of a Mixed Signal Graph will not correctly scale when the graph is set to "Scale Object with Pane" and the user decreases the size of the VI Front Panel.

Increasing the size of the pane will result in the graph growing and scaling its axes correctly, but decreasing the size of the pane will only shrink the graph without scaling the Y-Axis. The Y-Axis will now have a scroll bar due to not scaling.

Workaround:

Use the "Plot Area" Property Node to shrink the graph to appropriate size.

LabVIEW 2013 N/A 03/31/2014
430758 It is not possible to save a VI with the name of another VI in memory, even if they are in different libraries

LabVIEW does not check the library namespace when determining if a VI is being saved with a name that is already in use. If a VI is in memory, it is not possible to save another VI with the same name in the same project even if they are in different libraries.

Workaround:

Close the other VIs with the same name so they are not in memory.

LabVIEW 2013 N/A 03/14/2014
432182 Custom labels on a 3D bar chart do not display properly in a 2D view

Custom labels on a 3D bar chart will revert to a numeric value when viewed in a 2D Projection

Workaround:

N/A

LabVIEW 2013 N/A 03/14/2014
432523 Reordering elements of a cluster within the private data of a class can break VIs that reference the class

If you have a cluster within the private data of a class and you reorder the elements of the cluster, VIs that reference the class can become broken.

Workaround:

Close and reopen the LabVIEW project after reordering the cluster

LabVIEW 2013 N/A 05/22/2017
433596 The 3D Surface Plot does not draw correctly when the input data is an array of the same value

The plot is completely blank if the array contains only the same value. Changing one value correctly draws the 3D Surface Plot

Workaround:

Manually or programmatically toggle the Z-Axis range, or turn off Auto Scaling on Z-Axis, and the plot will appear

LabVIEW 2013 N/A 03/31/2014
437390 File Path control does not display "Browse" dialog if Start Path is an invalid network path.

LabVIEW may hang while waiting for Windows to locate an invalid network directory. The control's owning VI may hang while it searches for the directory, or it may appear that the "Browse" button does not have any affect and does not invoke a dialog. This can happen if the Start Path input in Browse Options... is an invalid path or if the Start Path in blank and the control's value is invalid.

Workaround:

Make sure the Start Path input is valid before selecting the Browse button. If the Start Path input is blank, change the File Path control's value to a known valid path before browsing.

LabVIEW 2012 N/A 03/24/2014
438751 Renaming a group in a Mixed Signal Graph crashes LabVIEW once there is a plot containing data

Workaround:

Create a Strict Type Definition from a new Mixed Signal Graph. Change and update the Type Def to change the name of the group

LabVIEW 2013 LabVIEW 2015 12/01/2014
442745 RF-RIO Instr Default Personality 5646R.lvproj's FPGA VI will hang on save.

Instrument driver\RFSA\5645R\Public\Apply Digital Correction.vi located in RF-RIO Instr Default Personality 5646R.lvproj will hang on save. This happens when removing the diagram disable structure. In addition, the VI cannot compile.

Workaround:

Currently, using the structure wrap included in the example code is recommended. If you only use one instance of the polymorphic VI, re-arrange the instances such that the instance you wish to use appears first in the list.

LabVIEW 2013 N/A 07/31/2014
443165 Modifying the dependencies of a Packed Project Library (PPL) may cause LabVIEW to crash

N/A

Workaround:

To avoid the crash, rebuild the PPL after modifying the dependencies.

LabVIEW 2013 LabVIEW 2015 01/30/2014
447789 "RecipeBkUp::SanityCheck()" Crash in LabVIEW

Workaround:

None

LabVIEW 2013 LabVIEW 2015 02/09/2016
449383 Interaction between dragged project items and subdigram labels

Dragging project items over subdiagram labels on loops or other structures prevents the user from placing the item on the block diagram. Examples of project items affected by this include shared variables and I/O nodes.

Workaround:

Avoid moving your mouse over the subdiagram label when dragging items from the project.

LabVIEW 2012 N/A 08/08/2016
449869 "ICallPiccCallback" 0x89B93EF0 crash in LabVIEW

Workaround:

Remove all "attached object" arrows

LabVIEW 2013 LabVIEW 2015 02/09/2016
451059 "CProjectItemWrapper::GetPropertyBag(IlvProjectPropertyBag**)" crash in LabVIEW

Workaround:

None

LabVIEW 2012 SP1 LabVIEW 2015 02/09/2016
453489 Minimizing the lvlib group in VI Hierarchy messes up the entire VI hierarchy.

Workaround:

None

LabVIEW 2014 LabVIEW 2015 02/09/2016
457854 Aborting a VI can leave VIs targeted by a Call By Reference node reserved permanently

N/A

Workaround:

Close the project to unreserve the VI

LabVIEW 2013 N/A 08/08/2016
458973 Writing a negative number to single point float Network Shared Variables through the OPC I/O Server fails.

Workaround:

Use Double precision shared variables instead.

LabVIEW 2013 N/A 03/31/2014
460106 In certain cases, there is a memory leak when a .NET object is used in a LabVIEW Interop Assembly

Workaround:

N/A

LabVIEW 2013 SP1 LabVIEW 2014 SP1 11/20/2014
461969 When using a class containing a DAQmx Physical Channel control, it will not properly load that information from an XML file.

The control can be changed and saved to the XML as expected and seen when opening the XML. However, when you try to load the channel from the XML it appears blank.

Workaround:

If you place the class cluster in an additional cluster the DAQmx Physical Channel control saves and loads as expected.

LabVIEW 2013 N/A 05/07/2014
462021 In LabVIEW for Mac, filtered menu tracking is not cancelled until the event's case finishes executing

If you are the filter event "Menu Activation?" and you discard the event, the menu activation will not be cancelled until that case in the event structure finishes executing. This may cause the menu to appear momentarily before it disappears.

Workaround:

Programmatically hide or disable the menu instead of filtering an event for it.

LabVIEW 2014 N/A 07/31/2014
462029 LabVIEW crashes when typecasting a RIO handle to a VISA handle

Workaround:

Cast RIO handle to string and pass it into a VISA resource VI, or use the flatten to string/unflatten to string VIs.

LabVIEW 2013 SP1 N/A 07/31/2014
464572 Reading a datalog file truncated from more than 128 records returns error 4 "End of file encountered"

Workaround:

N/A

LabVIEW 2011 SP1 N/A 05/09/2014
465422 In certain cases, LabVIEW Crashes When Deleting a Subdiagram Label From a Merged Flat Sequence Structure

Workaround:

Do not merge frames with Subdiagram Labels or hide the labels before merging.

LabVIEW 2012 SP1 LabVIEW 2015 05/07/2014
467735 "Format into File" produces Error 1 when appending to a file that has a size of 4 GB

See thisNI Communitypage for more information.

Workaround:

Use "Format Into String" and "Write to Binary File".

LabVIEW 2013 N/A 12/01/2014
468062 Path to URL.vi does not handle network path

Workaround:

Use the attached Path to URL.vi and \vi.lib\Platform\browser.llb\Open URL in Default Browser core.vi in your code.

LabVIEW 2013 SP1 LabVIEW 2015 12/01/2014
468139 .NET Callback Event VI keeps the Callback VI reserved even after calling a Close Reference VI is called

For example, when running the "Passing data to a .NET Event Callback.vi" example, after stopping the main example VI, the "Callback - EventHappened.vi" is still reserved.

Workaround:

I've come up with a work around for this problem. GC.Collect() can be called manually from the invoke node in a separate VI(Or the user could call it after un-registering the callback). This would un-reserve the callback VI. Steps : 1. Drop an invoke node in an empty VI 2. Right click on the node and in the menu under "Select Class" -> ".NET" choose Browse. 3. In the Class browser dialog navigate to mscorlib(4.0.0.0) assembly in the drop down 4. Once selected in the list below expand the system namespace and choose GC class. 5. Once this is done you can choose the Collect() static method. 6. You can unreserve the callback VI by running this VI.

LabVIEW 2013 SP1 N/A 05/07/2014
468921 Auto-populating folders may not update their contents correctly

Saving a web page file (.htm) from certain programs can result in the auto-populating folder displaying the web page file as a ".ht_" file, which can cause errors in build specifications and other parts of the program that rely on the files.

Workaround:

Close and reopen the project to correctly update the files in the auto-populating folder. Or, press f5 to refresh the project window.

LabVIEW 2013 SP1 LabVIEW 2015 04/30/2014
469070 In some cases, Fract/Exp String To Number VI does not convert the string correctly

Examples:"1E-9999" should return 0 but returns Inf"1E-12000" sould return 0 but returns 1E-1200"1E9999" should return Inf but return 0"1E12000" should return Inf but returns 1E1200

Workaround:

N/A

LabVIEW 2013 LabVIEW 2015 07/31/2014
469268 Formula Node and MathScript Node variable labels can shift to become misalligned

After opening and closing its VI, the label will no longer look centered inside its owning box

Workaround:

This should not affect functionality. Recreate the variable on the node's border to recenter the label

LabVIEW 2013 SP1 N/A 05/02/2014
470218 LabVIEW (64-bit) for Mac, does not show the login prompt for Revision History when starting LabVIEW

In Tools>>Options, you can set the "User Name to Record in VI Revision History" to "LabVIEW registration name" which adds the token "history.whereToGetName&#61,LabVIEW" to the LabVIEW.ini or LabVIEW.app file, for Windows and Mac OS X respectively. Changing the token to "history.whereToGetName&#61,prompt" should invoke a login dialog each time LabVIEW starts, but the dialog does not appear in LabVIEW (64-bit) for Mac.

Workaround:

After LabVIEW finishes launching, select Tools>>User Name to view the login dialog.

LabVIEW 2014 N/A 07/28/2014
470533 When creating a property accessor method of an EndevoGOOP400 type for a Simple DVR Template Class in the LabVIEW GOOP suite, LabVIEW generates Error 7

Workaround:

Manually create the property accessor.

LabVIEW 2013 SP1 N/A 07/30/2014
471675 Inverse FFT Function is very slow if inputs have NaN values

Workaround:

Programmatically detect if the array has NaN in it by using the "NaN Path Refnum?" VI and a OR Array Elements and case structure the inverse FFT function.

LabVIEW 2013 SP1 N/A 05/15/2014
471706 Cannot paste into destination name of installer properties in LabVIEW

Workaround:

Manually type the destination

LabVIEW 2013 LabVIEW 2015 02/09/2016
473149 In certain cases, flattening or unflattening a large cluster and class hierarchy may result in Error 1403

Workaround:

N/A

LabVIEW 2014 N/A 07/31/2014
473389 Unable to delete Waveform Chart or Graph plot entries

Workaround:

Change the number of plots visible. More information at: http://zone.ni.com/reference/en-XX/help/371361R-01/lvhowto/pl_number/

LabVIEW 2013 SP1 N/A 07/31/2014
474764 A VI can hang at Occurrences if Allow Debugging is Disabled

N/A

Workaround:

Enable debugging

LabVIEW 2012 SP1 LabVIEW 2015 04/24/2015
476362 With an Actor Framework project in LabVIEW 2013 SP1 and the LabVIEW GOOP Development Suite, LabVIEW may crash when exiting if the Message Classes are Updated.

Workaround:

Right click and run LabVIEW as Administrator.

LabVIEW 2013 SP1 N/A 07/31/2014
476710 Opening a VI Server Reference to two or more identically named VIs, contained in separate LabVIEW libraries in a running executable, can result in Error 1031

From a LabVIEW development environment, opening a VI Server Reference to two or more identically-named VIs, contained in separate LabVIEW libraries in a running executable, results in one successful VI reference and Error 1031 from all other Open VI Reference functions.

Workaround:

Rename the referenced VIs so there are no name duplicates across LabVIEW libraries

LabVIEW 2013 LabVIEW 2014 SP1 06/24/2014
476714 The INI file created for a LabVIEW built executable contains a truncated list of VIs in the "server.vi.access&#61," line when enabling TCP/IP with multiple Exported VIs

Workaround:

Manually list the missing VIs in the INI file

LabVIEW 2013 LabVIEW 2015 07/30/2014
477112 If you cancel the file dialog in Write to Measurement File Express VI, it will never be displayed again.

Workaround:

None

LabVIEW 2013 SP1 LabVIEW 2015 02/09/2016
477265 Large input for "byte count" causes decrease in performance for VISA Read on Linux RT

Workaround:

N/A

LabVIEW 2014 N/A 07/31/2014
477278 The [VersionNumber] Tag throws error 7 when used in an RT-EXE build specification.

Workaround:

None

LabVIEW 2013 LabVIEW 2015 02/09/2016
477280 When using [VersionNumber], Application Builder post-build VIs do not get passed the proper path

For example the build spec may have a app builder destination directory of:\Builds\[VersionNumber]The files are built into a directory like this:\Builds\1.0.0.3\And the path that is passed to the post build VI is:\Builds\[VersionNumber]

Workaround:

Parse the build path from one of the files generated from the build

LabVIEW 2013 LabVIEW 2015 04/24/2015
477352 In the TDMS File Viewer VI, the menu becomes partially hidden after making the plot legend visible

Workaround:

Restart the VI containing the TDMS File Viewer and the menu should be fully visible

LabVIEW 2013 SP1 LabVIEW 2015 07/31/2014
477864 When a number of controls are grouped on a tab control page, switching to that page takes a long time, proportional to the number of controls grouped

Workaround:

Ungroup controls on tab pages

LabVIEW 2013 LabVIEW 2015 07/30/2014
477954 VI Analyzer throws error 1 when analyzing project with a Networked Computer under the Target Folder.

Workaround:

Don't have this folder type in your project

LabVIEW 2013 LabVIEW 2015 02/09/2016
47819 2GB file size limit of datalog files

The maximum size of datalog files is 2 GB.

Workaround:

N/A

LabVIEW 8.0 N/A 09/01/2007
478232 In certain cases, LabVIEW may incorrectly crisscross wires during loop creation

When adding a loop around existing code, LabVIEW may reconnect wires to the incorrect tunnels on the border of the loop

Workaround:

Manually reconnect the appropriate wires and tunnels

LabVIEW 2014 N/A 06/19/2014
479161 Error 7 When Building Installer for EXE with Custom Destinations

Workaround:

Don't use custom internal destinations for dynamically called VIs

LabVIEW 2014 LabVIEW 2015 02/09/2016
48016 Unsigned int32 loses value in formula node when you write to the most significant bit

If you wire a hex value greater than x7FFFFFFF as an unsigned, 32-bit integer to a Formula Node, LabVIEW coerces the value to 0. If you use a negative number for U32 input/output variable, LabVIEW will coerce the value to 0.

Workaround:

1. Use the Mathscript node or LabVIEW code for the operation that involves an unsigned, 32-bit integer.2. Use signed 32-bit integers instead of unsigned 32-bit integers in the formula node.

LabVIEW 8.0 N/A 09/01/2007
480165 Concurrent calls of reentrant Data Value Reference accessors crashes LabVIEW on Windows and Real-Time

Workaround:

setting the methods to be non-reentrant or statically-dispatched prevents the crash

LabVIEW 2013 SP1 LabVIEW 2015 02/09/2016
480386 ActiveX call to open PDF (Adobe Reader 11.0.07) results in LabVIEW crashing

More information at https://forums.adobe.com/message/6396203#6396203

Workaround:

Downgrade to an earlier versions of Adobe Reader (11.0.6 and earlier)

LabVIEW 2013 N/A 07/31/2014
480480 Invoke Node shows the English shortname at the first drop in German LabVIEW

N/A

Workaround:

N/A

LabVIEW 2014 LabVIEW 2015 04/24/2015
480921 Unable to delete and re-add a desitnation folder successfully in build specification of a LabVIEW Installer

Workaround:

Delete the build specification from the project explorer and create a new one

LabVIEW 2013 SP1 LabVIEW 2015 04/24/2015
481414 In the LabVIEW GOOP design suite, you are unable rename a method of a GOOP class under an RT target from the project

Workaround:

Double click the method, open the VI, and navigate through top menu bar Tools >> GOOP >> Create VI Icon to rename the method

LabVIEW 2013 SP1 N/A 07/31/2014
485336 Deleting a second y-axis on a waveform graph with a cursor crashes LabVIEW

When using a waveform graph indicator, it is possible to crash LabVIEW with an access violation error 0xC0000005 at EIP&#61,0x00FE9E79 by creating two y-axis scales, creating a graph cursor, changing the cursor's associated y-axis, and then deleting the original y-axis scale.

Workaround:

Remove the scale from the waveform graph, remove the unwanted y-axis scale, then recreate the cursor.

LabVIEW 2013 SP1 N/A 06/17/2015
487258 A LabVIEW 2014 Web Service does not run when it is built into an executable and then installed via an NI Installer

A LabVIEW component is missing from the 2014 installer which is necessary to run the LabVIEW Web Service.

Workaround:

This is fixed in the LabVIEW 2014 f1 Patch. SeeLabVIEW 2014 Patch Detailsfor more information.

LabVIEW 2014 LabVIEW 2014 SP1 11/13/2014
489848 "Remove empty cases" option in case structure disappears when Subdiagram Label is visible.

Workaround:

N/A

LabVIEW 2014 LabVIEW 2015 02/09/2016
491159 Type Definition instance does not require manual update (new to LabVIEW 2014) if last element of enum was deleted

Workaround:

Rename the element to trigger a manual update

LabVIEW 2014 LabVIEW 2014 SP1 11/13/2014
491225 Installing the LabVIEW 2014 Run-Time Engine via an NI Installer can prevent the NI System Web Server from starting if older versions of LabVIEW are also present or installed.

Installing the LabVIEW 2014 RTE on a system with older components, such as LabVIEW 2013 Development System and LabVIEW 2014 Run-Time Engine, are the only systems affected. Systems with the full LabVIEW 2014 Development System are not affected.

Workaround:

Include "NI Web-Based Configuration and Monitoring 14.0" in your NI Installer.This issue has been fixed in the LabVIEW 2014 f2 Patch.

LabVIEW 2014 LabVIEW 2014 SP1 11/13/2014
491714 Using Probes while Remote Debugging with General Error Handler VI present can cause LabVIEW 2014 to hang.

Workaround:

Remove the General Error Handler VI

LabVIEW 2014 LabVIEW 2014 SP1 11/13/2014
492341 LabVIEW TDMS Advanced Asynchronous Write does not return error when target disk is full.

Workaround:

Use the TDMS Reserve File Size Function to allocate disk space before writing

LabVIEW 2014 N/A 12/01/2014
492898 Open VI Reference hangs on second call

Workaround:

This issue has been fixed in the LabVIEW 2014 f2 Patch.

LabVIEW 2014 LabVIEW 2014 SP1 09/23/2014
493624 Change of .NET assembly version requires manual relink of static class methods/properties

Workaround:

N/A

LabVIEW 2013 SP1 N/A 06/17/2015
493662 dotNET Constructor Node cannot handle overloads with different enum parameter types

Workaround:

Create a wrapper assembly to call from LabVIEW

LabVIEW 2014 N/A 06/17/2015
493664 Free Label arrow pointing to a wire inside a structure, such as For Loop or While Loop, will crash LabVIEW if user selects the structure and attempts to Clean Up Diagram before VI is saved

Workaround:

Save the VI before selecting Clean Up Diagram

LabVIEW 2014 N/A 12/01/2014
494409 WebDAV Open Session VI does not output an error if unable to open a session

Workaround:

Use the Path Info VI after the Open Session VI. It should timeout with Error 56 if the session is invalid.

LabVIEW 2014 N/A 12/01/2014
497131 The WebDAV Put.vi when executed on a cRIO target can lead to a memory leak

Workaround:

N/A

LabVIEW 2014 LabVIEW 2015 11/20/2014
497755 Cannot reset the values of Build Specification Version in Set Build Specification Version VI to zero

Workaround:

The version can be reset in the build specification directly in the LabVIEW Project

LabVIEW 2014 LabVIEW 2015 12/01/2014
502081 Ctrl&#43,shift&#43,E (find in project) doesn't work for clone VIs.

Workaround:

N/A

LabVIEW 2014 LabVIEW 2015 02/09/2016
504066 Save for previous fails if file path is too long

Save for previous copies the folder being saved to a temp location, if the resulting file paths exceed the limit defined by the OS, the function fails.

Workaround:

Copy the folder being saved to the root directory to reduce the file path length and Save for Previous from that location.

LabVIEW 8.5 N/A Feb 18, 2020
50420 Update the Pulse Transition Measurement Express VI

The terminology and measurement definitions for the Transition Measurements VI comply with IEEE Standard 181-2003, IEEE Standard on Transitions, Pulses, and Related Waveforms. However, the Timing and Transition Measurements Express VI does not comply with this IEEE Standard.

Workaround:

The Slew rate refers to the transition slope. The Preshoot refers to the pre-transition undershoot (rising pulse) or the pre-transition overshoot (falling pulse). The Overshoot refers to the post-transition undershoot (rising pulse) or the post-transition overshoot (falling pulse).

LabVIEW 8.5 N/A 09/01/2007
504716 Advanced Asynchronous Write function does not return an error when target disk is full or removed

N/A

Workaround:

Use the TDMS Reserve File Size Function to allocate disk space before writing

LabVIEW 2014 N/A 08/08/2016
507856 Replacing an Intensity Graph with z-axis autoscaling enabled with a Waveform Graph or XY Graph causes LabVIEW to crash

Workaround:

Delete the Intensity Graph and add a Waveform Graph or XY Graph rather than using the replace option.

LabVIEW 2014 N/A 06/17/2015
508651 Custom conditional disable symbols not copied to EXE when debugging and enhanced DSC run-time support are enabled

Workaround:

Disable either debugging or enhanced DSC run-time support.

LabVIEW 2014 N/A 06/17/2015
509173 Unhandled Exception can occur if absolute path for system DLL used in CLFN

If you use a specific path to a system DLL (C:\windows\system\user32.dll) and build your VI into an application it will create a copy of the DLL inside the application. This can cause an unhandled exception when running

Workaround:

LabVIEW searches in the system directory when looking for DLLs. If you are using a system DLL simply put the name in the in DLL Path box in the CLFN properties. In the example above you would simply put "user32.dll"

LabVIEW 8.6 N/A Feb 17, 2020
509876 Bundle by Name function can send wrong pointer into subVI with Call Library Function Node

If a main VI has the output of a Bundle by Name function connected to a subVI, a Call Library Function node within the subVI can receive the wrong pointer from the wired cluster.

Workaround:

Remove the Bundle by Name function or the subVI

OR

Replace the control input to the Bundle by Name function with a constant

LabVIEW 2013 SP1 LabVIEW 2019 SP1 08/08/2016
510218 Create Mask.vi does not work in conjunction with the Get Image Subset.vi in LabVIEW

Workaround:

Swap the Dimension Size inputs of the Reshape Array in the Case Structure at the bottom of Get Image Subset.vi.

LabVIEW 2012 SP1 N/A 06/17/2015
510881 LabVIEW Crash when saving Library containing Shared Variables with Class Object in Typedef.

Workaround:

Don't add class objects to typedefs used for Shared Variables

LabVIEW 2013 SP1 LabVIEW 2015 02/09/2016
511646 In rare cases, Mixed Signal Graph and Digital Waveform Graph cause a memory leak

Workaround:

N/A

LabVIEW 2014 N/A 11/20/2014
511691 In specific cases, creating source distribution with myRIO can cause LV 2014 to crash

Workaround:

If none of the additional exclusions are applied, then the source distribution should build successfully. This would only be viable for systems with dependencies in vi.lib, user.lib, and instr.lib directories already present on the target system.

LabVIEW 2014 N/A 06/17/2015
51179 Error 6 occurred at Create Folder in Create Directory Recursive.vi when building an application (EXE), shared library (DLL), source distribution or web service

When building a Build Specification, the build process fails with Error 6 at Create Folder in Create Directory Recursive.vi. This usually happens if the path one of the files generated by the build (temporarily during the build process or as part of the output) is too long. The operating system requires paths for files to be less than 255 characters.

Workaround:

1. Use a shorter path for your build destination (i.e. c:\build\) and if necessary copy the output to the final location you need.2. A. For application (EXE) and shared library (DLL) build specifications, place a checkmark in the Use LabVIEW 8.x file layout checkbox on the Advanced page of the Properties dialog box.2. B. For source distribution or web service build specifications, uncheck the Preserve disk hierarchy checkbox on the problem Destination on the Destinations page of the Properties dialog box.

LabVIEW 8.2.1 N/A 10/06/2008
51185 Cannot save VI as the same name as missing library member VI

If a library contains a VI and the VI is missing, you should be able to save a VI as the same name as the missing VI in order to rebuild the missing VI. Currently, LabVIEW does not allow this.

Workaround:

Delete the item from the library, save the new VI as the same name as the missing VI and then move the VI into the library.

LabVIEW 8.5 N/A 09/01/2007
511987 In certain cases, VI Merge crashes with Custom Control files

Workaround:

Select Options...Uncheck "Auto-resolve", "Block Diagram cosmetic changes", "Make space for block diagram changes", and "Link block diagram to front panel changes"

LabVIEW 2013 N/A 06/17/2015
512464 After making a change in Format Into String, the containing VI does not recompile automatically.

Since the VI does not recompile automatically, it may appear incorrectly broken or able to run when the opposite is true.

Workaround:

Attempt run the VI to see the updated changes or used CTRL &#43, RUN to force a recompile on the containing VI.

LabVIEW 2014 LabVIEW 2015 04/24/2015
51311 LabVIEW does not maintain child-only item setting when dragging an item within a tree

If you have a tree item with the child-only setting, and then drag it within the tree, LabVIEW loses the child-only setting.

Workaround:

Use tree events to (1) get the child-only flag setting when the user begins a drag, and (2) reset the child-only flag after completing a drop.

LabVIEW 8.2.1 N/A 09/01/2007
513188 Improved Bookmark Manager performance by adding additional caching.

Workaround:

N/A

LabVIEW 2013 LabVIEW 2015 02/09/2016
513457 "Change to Array" menu option should not appear on tab controls or XControls.

Workaround:

N/A

LabVIEW 2012 LabVIEW 2015 02/09/2016
514789 Autotuning PID Online.VI Example Reads Proportional Gain 'NaN' with the Relay Technique.

When running the Autotuning PID Online.vi example, with the Relay Technique the "Tuned PID gains" output of proportional gain (Kc) shows "NaN" when the program believes tuning is completed by flashing "tuning completed?".

Workaround:

Tune the individual terms first. Start by first tuning for P until the response is stable. Then continue to tune by switching to PI. Lastly, repeat the process for PID.

LabVIEW 2014 N/A 02/04/2015
515054 Icon transparency of VIs is not maintained when building a Source Distribution

Workaround:

Unknown (use some other distribution method?)Opening and closing the Icon Editor for the effected VIs fixes transparency issues

LabVIEW 2014 LabVIEW 2015 SP1 04/24/2015
515300 NamedBundler function in LV Scripting does not work properly when the reference is opened from a New VI function

Workaround:

Use the Open VI Reference and Save A Copy functions, rather than New VI function, to create a new instance of a vi from a template.

LabVIEW 2014 N/A 06/17/2015
515779 Invoke node Append String returns error 1043 while display style set to backslash "\" codes

Workaround:

Toggle to a different display style before using the Append String method

LabVIEW 2013 LabVIEW 2015 03/11/2015
516144 A VI used in a LabVIEW Remote Front Panels may hang when it calls the "Strings[]"Property Node

Workaround:

If before opening the VI's Front Panel, use the lock.RP property node and unlock it after the Front Panel has been opened.

LabVIEW 2014 N/A 06/17/2015
516217 The WebDAV Put.vi when executed on a cRIO target can lead to a memory leak

Workaround:

N/A

LabVIEW 2013 LabVIEW 2015 11/20/2014
516227 UI Thread LabVIEW code cannot execute while a Time Stamp Control's 'Set Time and Date' window is visible.

Workaround:

N/A

LabVIEW 2014 LabVIEW 2015 02/09/2016
517128 Error 1357 when building using two VIs with the same name and only capitalization differences.

Workaround:

Make sure your VIs have exactly the same name (so that LabVIEW catches that and gives them their unique directories) or make sure the VIs' names differ in more than capitalization.

LabVIEW 2013 SP1 LabVIEW 2015 07/20/2015
519216 LabVIEW crash when closing subVI Icon Editor that was opened from VI Hierarchy.

Workaround:

Open the subVI icon editor from the subVI's front panel

LabVIEW 2014 LabVIEW 2015 02/09/2016
52027 Cannot use the 'New>>VI for Override...' dialog to create override of password-protected VI unless you have the password

You use the 'New>>VI for Override...' dialog to override an ancestor VI in a LabVIEW class if the VI you want to override is password-protected.

Workaround:

Make a public VI which wraps the functionality of the private VI, and instruct others to override the public VI.

LabVIEW 8.5 N/A 09/01/2007
521856 Rare LabVIEW crash when using "Panel Close?" filtering event and "Quit LabVIEW" function

N/A

Workaround:

Either do not use the "Panel Close?" event, do not open the front panel of the VI being closed, or turn off scrollbar visibility using a property node.

LabVIEW 2014 SP1 N/A 08/08/2016
522606 Error Ring does not adhere to dataflow in an executable or in a VI with debugging disabled

See this forum for more details: http://forums.ni.com/t5/LabVIEW/Error-ring-excluded-in-executable/td-p/3100932

Workaround:

Use an error constant

LabVIEW 2013 N/A 06/17/2015
52263 Some operations on integer waveforms lose dt value

Some functions, such as Absolute Value and Logarithm Base 10 operate as you expect with DBL Waveforms, but when you apply the same functions to an I16 waveform, for example, the Absolute Value function works as you expect while the Logarithm Base 10 function loses the sampling interval dt value. LabVIEW resets the sampling interval dt value to 1.00. If the input waveform to the log function has a time stamp for t0, that value is also lost.

Workaround:

Extract the Y-array of the waveform and perform the needed operations on Y before re-building the waveform.

LabVIEW 8.0.1 LabVIEW 2015 09/01/2007
525685 Error -2628 is returned when parsing an XML file with a Document Type Definition file

Workaround:

N/A

LabVIEW 2014 N/A 06/17/2015
526044 VISA Resource and DAQmx resource controls in VIs called using COM interface sometimes incorrectly retain their value from a previous VI call rather than using the value provided as input.

Workaround:

Configure your VI to dynamically unload the VI, set the "resvForCall" input to be false in the GetVIReference method, or typecast a string of the desired name to the desired IO Resource type before sending it to the call method.

LabVIEW 2014 LabVIEW 2015 05/06/2015
528963 File Dialog Express VI crashes when passed a null hex string as the pattern input

The File Dialog Express VI crashes LabVIEW when a null string is passed as the pattern (all files) input. The crash report states that an "Exception: Noncontinuable exception (0xC0000025) at EIP 0x000000" occurs.

Workaround:

Avoid passing the hexadecimal code for a null string to this input terminal. Programmatically detect these error situations and handle them appropriately.

LabVIEW 2013 SP1 N/A 08/08/2016
529278 MATLAB Script Node can output different data in LabVIEW 32-bit vs. 64-bit

N/A

Workaround:

Use LabVIEW 32-bit for MATLAB Script Nodes

LabVIEW 2014 SP1 N/A 08/08/2016
529943 Incorrect behavior when creating a .NET Interop Assembly with typedefs

When you have multiple different typedefs with identical definitions (i.e, multiple numeric typedefs), only one of them is exported to a .NET typedef.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2016 N/A Feb 14, 2020
530156 Setting binding properties of a control within a preallocated clone subVI or XControl sets the property for all instances of the subVI or XControl

If the BindingPath property is set on a control within a preallocated clone subVI or XControl, all instances of the controls in the subVI or XControl update their BindingPath rather than the one where the property was set

Workaround:

Create a unique SubVI or XControl for each instance

LabVIEW 2016 N/A Feb 17, 2020
530520 Error -2548 is returned when TDMS Create Scaling information is applied on all channels

Workaround:

Call Set Channel Information after calling TDMS Create Scaling Information.vi.

LabVIEW 2014 N/A 06/17/2015
530595 Not a Refnum Primitive returns incorrect value when evaluating a specific type of "Invalid Refnum"

Workaround:

Use a property node, which should give you an error when attempting to use the reference, or implement your solution without the primitive by following this implementation: https://lavag.org/topic/15546-are-you-misusing-the-not-a-refnum-function-and-putting-your-app-at-risk/

LabVIEW 2012 SP1 N/A 06/17/2015
534471 When building a packed project library containing classes, changes in class inheritance do not propagate to calling VIs

Workaround:

This is fixed in the LabVIEW 2015 f1 Patch

LabVIEW 2015 LabVIEW 2015 SP1 11/24/2015
534812 "Create from Data Type" Method Crashes LabVIEW if the data type is a Type Definition.

N/A

Workaround:

Before using a variant data type as an input, use "DisconnectFromTypedef.vi" from the VI.lib folder.

LabVIEW 2014 SP1 N/A 08/08/2016
536763 Popup Menu can appear only limited number of times before LabVIEW crashes.

The number of of times the popup menu can be accessed before the crash depends on the number of items within a menu and how many times this menu is populated.

Workaround:

N/A

LabVIEW 2010 SP1 N/A 08/08/2016
537078 Case Structure auto-complete functions incorrectly when used with Enum Controls in LabVIEW 2015

If the user triple-clicks on the case to change the Selector Label and types more than 5 letters, the subsequent letters are appended to the label immediately following the final letter of the auto-completed value. For example, "Boolean" becomes "Booleanna".

Workaround:

Use quotation marks: Type - "Boolean" (including the quotes), for example.

LabVIEW 2015 LabVIEW 2015 SP1 11/24/2015
537859 LabVIEW 64-bit crashes when selecting a result from the Search text box on Windows 10

Workaround:

Use LabVIEW 32-bit or search the LabVIEW Help, LabVIEW Palettes, etc. separately

LabVIEW 2015 LabVIEW 2015 SP1 11/24/2015
538332 Make Space/Remove Space does not work when Bookmark Manager is open and there is a bookmark in the VI.

N/A

Workaround:

This issue has been fixed in the LabVIEW 2015 f2 Patch

LabVIEW 2015 LabVIEW 2015 SP1 11/24/2015
542232 LabVIEW executables with ActiveX Server enabled do not have read-only properties

A LabVIEW 2015 executable that has the ActiveX server option enabled will be missing several ActiveX properties, such as "ApplicationDirectory" and "AppName".

Workaround:

This issue has been fixed in the LabVIEW 2015 f2 Patch.

LabVIEW 2015 LabVIEW 2015 SP1 11/24/2015
542436 Block Diagram Cleanup on the Receive Message.VI in Actor Framework can cause an access violation crash within LabVIEW.

Opening\vi.lib\ActorFramework\Actor\Receive Message.vi and using Clean Up Diagram can cause LabVIEW to crash with an access violation.

Workaround:

1. Excluding the bottom comment when doing a block diagram cleanup on this vi will avoid a crash.

LabVIEW 2015 N/A 08/08/2016
542858 In rare cases, LabVIEW applications that contain a Web Service may crash on exit.

Workaround:

No workarounds at this time.

LabVIEW 2013 LabVIEW 2015 SP1 11/24/2015
543507 DAbort 0x2CADF6E3 caused by scrolling the mouse wheel within an array

N/A

Workaround:

This issue has been fixed in the LabVIEW 2015 f2 Patch

LabVIEW 2015 LabVIEW 2015 SP1 11/24/2015
544257 Inplace issue can occur when using LabVIEW 32-bit on a 64-bit operating system.

Running a VI that calls a subVI containing a Call Library Function Node to the kernel32.dll IsWow64Process can cause the returned value of the dll to be incorrect.

Workaround:

Adding an "Always Copy" dot before the control that is wired to the Front Panel Terminal within the subVI fixes the issue.

LabVIEW 2014 N/A 08/08/2016
544623 LabVIEW 64-bit for Mac OS can improperly create special characters.

LabVIEW 64-bit for Mac OS improperly creates special characters such as the 'degree' symbol and 'micro' symbol that cannot be read correctly.

Workaround:

Avoid using special characters.

LabVIEW 2015 N/A 08/08/2016
545175 In some cases, using Sort 1D Array and Array Max &amp, Min or Less Than on a cluster would report incorrect data

Workaround:

This issue has been fixed in the LabVIEW 2015 f2 Patch

LabVIEW 2015 LabVIEW 2015 SP1 11/24/2015
545835 LabVIEW Runtime Engine encounters Worker Thread Limit when using web services on Linux RT-based cRIO

On a Linux RT-based cRIO, the LabVIEW Runtime Engine can get into a deadlocked state waiting for action from the Web Server. This can cause process hangs resulting in a Worker Thread Limit error reported to the user by the Web Server.

Workaround:

Use a mechanism other than web services.

LabVIEW 2015 N/A 08/08/2016
552304 SMTP Client VI Example incorrectly converts some characters when placed in subject line

Email sent using the SMTP Client VI shipping example converts "!", ":", and "~" to "?" in the subject line of emails.

Workaround:

N/A

LabVIEW 2013 SP1 N/A 08/08/2016
552345 In rare cases, updating an IMAQ indicator and a LabVIEW Listbox at a high rate in two different, but visible, VIs can cause LabVIEW to crash

Workaround:

This has been fixed in the LabVIEW 2015 f3 Patch and LabVIEW 2014 SP1 f5 Patch.

LabVIEW 2014 LabVIEW 2015 SP1 11/24/2015
558774 Constructor node for FolderDialogBox from Windows.System.Forms (4.0.0) causes hang during execution

In recent versions of LabVIEW, placing a constructor for a FolderDialogBox object from Windows.System.Forms (4.0.0) will work successfully, but the containing VI will hang during execution.

Workaround:

Do not use FolderDialogBox objects.

LabVIEW 2012 SP1 N/A 08/08/2016
558890 LabVIEW 2015 leaks memory when copying an empty array of strings into a non-empty array of strings

Workaround:

Change the empty array of strings to a 1-element array.This has been fixed in the LabVIEW 2015 f3 Patch.

LabVIEW 2015 LabVIEW 2015 SP1 12/08/2015
558891 In some scenarios, LabVIEW Menu positions within a VI or project are offset in Windows 10

For multiple displays, Windows 10 allows you to set different "size for text and other items" (magnification) for each display. In the case you have different magnifications between displays, the drop down menus of a VI or project are offset to the right and down. This can be dramatic (even off the screen) when the two magnifications are very different.

Workaround:

Use a consistent magnification level for all displays.

LabVIEW 2014 SP1 N/A 08/08/2016
559606 In rare cases, leaving the Index input of Index Array function retrieves correct data but can cause other math functions to return incorrect results.

Workaround:

Wire the index terminal of the Index Array function.

LabVIEW 2013 LabVIEW 2015 SP1 02/03/2016
561615 In specific cases, building a LabVIEW executable with shared variables causes Error 1003 during the build.

The user will get an error saying, "VI containing Shared Variable node needs to be loaded in a project" on the Build Errors Dialog.

Workaround:

Save the VIs in the project that contain shared variables.

LabVIEW 2015 SP1 N/A 03/03/2016
563825 In certain rare cases, the Not A Number/Path/Refnum? function can cause LabVIEW 64-bit to crash, LabVIEW 32-bit is unaffected. Note: A recompile of the VI using the function is required to apply the fix.

Workaround:

This has been fixed in the LabVIEW 2014 SP1 f5 Patch

LabVIEW 2014 LabVIEW 2015 SP1 02/03/2016
565884 When creating .NET assemblies in LabVIEW, 1-dimension arrays of doubles or strings are represented as 2-dimension arrays of rank 1

When creating .NET assemblies in LabVIEW, 1-dimension arrays of doubles or strings are represented as 2-dimension arrays of rank 1. This can create an issue when the assembly is used in Visual Studio 2015 which will not accept 2-dimensional arrays of rank 1.

Workaround:

Pass a 2D array in LabVIEW instead of a 1D array.

LabVIEW 2013 SP1 N/A 08/08/2016
567353 When an XNode output is wired to the Loop count of a Parallel For Loop the VI breaks.

Connecting the output of an XNode (such as Match Regular Expression) to the count terminal of a Parallelized For Loop will result in a broken VI. The error list will also be empty in this situation.

Workaround:

Put an "Always Copy" between the output of the XNode and the Parallel For Loop count terminal

LabVIEW 2012 SP1 N/A 08/08/2016
570102 Calling the "Web Server: Server Active" property causes a small memory leak.

Calling the "Web Server: Server Active" property on any supported platform (including RT) creates a small memory leak.

Workaround:

Restart the application to allow the OS to reclaim the memory, or do not call this property often.

LabVIEW 2014 N/A 08/08/2016
570754 Linear Fit produces NaN result if X input value is too large

Linear Fit produces NaN result if X input value is too large. Values above around 2.2x10^9 in LabVIEW 32 bit or 4.9x10^7 in LabVIEW 64 bit may exhibit this behavior.

Workaround:

Modify your data to smaller absolute values before using this function.

LabVIEW 2015 N/A 06/10/2016
571353 XNode can cause Dirty Dot when no parameters are modified

When abilities of XNodes are called, LabVIEW can erroneously report that changes have been made to the VI and prompt the user to save.

Workaround:

N/A

LabVIEW 2015 N/A 08/08/2016
574329 Error 4 thrown in executable but not in development environment

Sometimes after manipulating the format specifier on the Open/Create/Replace primitive and then saving and reopening the VI, the VI can throw Error 4: End of File encountered on the next run. This may also occur when the application is run as an executable.

Workaround:

N/A

LabVIEW 2015 N/A 08/08/2016
574488 Upgrading to Mac OS X 10.11 (El Capitan) prevents Source Control in LabVIEW from finding Perforce

Mac OS X El Capitan no longer allows third party applications to be installed in /usr/sbin or /usr/bin. This is the default directory where many third-party applications have been stored in the past including Perforce. OS X El Capitan actually strips out any files from this directory that were user installed. Therefore, if you have Peforce installed in /usr/sbin, are running OS X 10.10, and upgrade to OS X 10.11, it strips out the Perforce files.

Workaround:

Manually copy Peforce back to /usr/bin (need admin rights).

LabVIEW 2015 SP1 N/A 03/01/2016
576990 Assembly created by Web Service Importer from WSDL throws error 1172

In certain cases, it is possible for the Web Service Importer tool in LabVIEW to throw error 1172 when trying to import a WSDL schema.

Workaround:

Remove complex data types from the WSDL file.

LabVIEW 2015 N/A 08/08/2016
578085 Saving a very large VI in LabVIEW 2015 and later can take longer than in previous versions

When compared to save times in earlier versions of LabVIEW, saving a large VI in LabVIEW 2015 and later takes a longer amount of time to complete.

Workaround:

Try the steps listed in this KB to minimize save time: http://ae.natinst.com/public.nsf/web/searchinternal/e43b32c14030c3b686256c1e0044d9b6?OpenDocument

LabVIEW 2015 N/A 08/08/2016
583670 If LabVIEW 2016 is installed, installers built in any version of LabVIEW will not work on Windows 7 RTM and older

See the following KB for details: http://knowledge.ni.com/KnowledgeArticleDetails?id&#61,kA00Z0000019LkCSAU?OpenDocument

Workaround:

Do not install LabVIEW 2016 on a computer which builds installers for Windows 7 RTM, Windows Vista, Windows XP SP3, and older.

LabVIEW 2015 SP1 N/A 08/08/2016
584455 Certain Silver Controls appear differently on Front Panel versus Print Output

When using the File >> Print option to print a Front Panel containing a Silver Boolean Control or Silver Meter Indicator, the printed version might not match up with the real values or style.

Workaround:

Use other style controls

LabVIEW 2016 N/A 08/08/2016
584837 Mass compiling a project from project explorer in certain cases can cause LabVIEW to hang.

Mass compiling a project from project explorer with an unsaved VI can cause LabVIEW to hang.

Workaround:

N/A

LabVIEW 2012 SP1 N/A 04/29/2016
585867 LabVIEW 64-bit can crash while closing a VI containing certain ActiveX containers

Certain ActiveX containers such as Microsoft InkEdit Controls can cause complications when they are unloaded from memory in LabVIEW 64-bit, such as when the containing VI is closed.

Workaround:

N/A

LabVIEW 2015 N/A 08/08/2016
590224 In some cases, using an XControl in a PPL can cause LabVIEW to hang

If you build an XControl into a PPL and include the XControl on the front panel of a VI that is also built into the PPL, the VI can hang in some cases.

Workaround:

N/A

LabVIEW 2015 SP1 N/A 05/22/2017
596788 The struct ErrorCluster from InteropAssembly throws case sensitivity error in Visual Basic

The user gets the following error when using the struct ErrorCluster in Visual Basic: "'Status' is ambiguous because multiple kinds of members with this names exist in structure 'ErrorCluster'".

The struct NationalInstruments.LabVIEW.Interop.ErrorCluster defined in the DLL NationalInstruments.LabVIEW.Interop.dll has the following variable definition:

Public code As Integer

Public source As String

Public status As Boolean

Public Sub New(statusIn As Boolean, errorCode As Integer, errorMessage As String)

Public ReadOnly Property Code As Integer

Public ReadOnly Property Source As String

Public ReadOnly Property Status As Boolean

The first three members have the same name of the last three aside from the capitalization of the first letter. Although MSIL is case-sensitive, VB is case-insensitive, which is therefore causing the error.

Workaround:

1. Use the generic .NET Exception, which will have the same information as the ErrorCluster.

2. Build a wrapper in C#, then use that in VB.NET

LabVIEW 2015 SP1 N/A 05/22/2017
599746 When building a web service into an EXE and making an installer, some software dependencies are not automatically selected as additional installers

If you build a web service into an EXE that has method VIs with software dependencies, such as the use of a hardware driver, only VIs with dependencies that are included as Startup VIs for the web service will be automatically selected as additional installers. Any method VI that is not a Startup VI will not have its software dependencies automatically selected.

Workaround:

Build the web service into the installer rather than the EXE or manually include the required software dependencies

LabVIEW 2015 SP1 N/A 05/22/2017
602529 Open/Create/Replace File does not return an error when attempting to create a file name that is restricted by the OS

When attempting to create a file with the Open/Create/Replace File primitive, the file will not be created but LabVIEW will not return an error. Examples of file names that are restricted by the OS are COM8.txt, LPT4.txt, etc.

Workaround:

N/A

LabVIEW 2010 SP1 N/A 05/22/2017
603204 When using a cylindrical coordinate system on a 3D scatter plot, the color ramp legend does not reflect the displayed color gradient

After changing the coordinate system to cylindrical, the graph will correctly display the color gradient according to distance from the origin. However, the legend will display the color ramp based on the minimum and maximum values of the z axis.

Workaround:

N/A

LabVIEW 2015 SP1 N/A 05/22/2017
606191 Building a .NET Interop Assembly with an array of classes as an output fails

When an exported VI has an array of classes as an output, attempting to build the .NET Interop Assembly results in error 1172.

Workaround:

Extract the data from the classes then bundle and output the data as an array of clusters

LabVIEW 2015 SP1 N/A 05/22/2017
607058 Flattening an EXT representation numeric to JSON causes loss of precision

N/A

Workaround:

Use Format Into String followed by Flatten to JSON

LabVIEW 2013 SP1 N/A 05/22/2017
607411 When using a LabVIEW-built .NET Interop Assembly in an ASP .NET application, the first call to the assembly will return a NullReferenceException

N/A

Workaround:

The exception only occurs on the first call to the assembly, so using a try-catch block to handle the exception will allow subsequent calls to behave normally.

LabVIEW 2015 SP1 N/A 05/22/2017
613423 Registering for an event for multiple boolean controls can fail in specific configurations

When passing a mixture of strict and non-strict boolean references in a cluster to the event source terminal of the Register For Events node, the input wire will break if any strict references are not the first elements of the cluster.

Workaround:

Use a Switch mechanical action, group the references with Build Array, or place any strict references at the beginning of the cluster.

LabVIEW 2016 N/A 05/22/2017
614154 Renaming a shared variable with a special character in its name (ö/ü/ä/ß) fails when the project is reopened

If you attempt to rename a shared variable that has a special characters in its name, the name will revert to the original name when the project is reopened

Workaround:

Do not use special characters in shared variable names

LabVIEW 2016 N/A 05/22/2017
616849 LabVIEW files are saved without an extension after attempting to save with an invalid character

If you attempt to save a LabVIEW file with an invalid character (such as ?), the file is correctly not saved. However, if you remove the invalid character and save the file, it will be saved with no extension on disk.

Workaround:

After saving, add the correct extension to the file

LabVIEW 2010 SP1 N/A 05/22/2017
617826 LabVIEW will not generate a Key Down event if the mouse is held down on a cell inside a table control

If you hold the left mouse button down on a cell inside of a table control, LabVIEW will not generate a Key Down event on the first key press. Subsequent key presses will generate the event as normal

Workaround:

N/A

LabVIEW 2015 SP1 N/A 05/22/2017
618568 Reference leaks with the Audio DataPlugin

Calling the Write Data [Channel] Express VI with the Audio DataPlugin in a loop causes LabVIEW to leak references, causing memory growth over time

Workaround:

N/A

LabVIEW 2016 N/A 05/22/2017
619819 Icon transparency of VIs is not maintained when building a Packed Library

Workaround:

This seems to be okay in LabVIEW 2014 but not 2015 or 2016

LabVIEW 2016 LabVIEW 2018.0 01/23/2018
624802 Setting binding properties of a control within a preallocated clone subVI or XControl sets the property for all instances of the subVI or XControl

If the BindingPath property is set on a control within a preallocated clone subVI or XControl, all instances of the controls in the subVI or XControl update their BindingPath rather than the one where the property was set

Workaround:

Create a unique SubVI or XControl for each instance

LabVIEW 2016 N/A 05/22/2017
625718 The Web Publishing Tool has incompatibility issues with Internet Explorer 11

When the Web Publishing Tool tries to create a pop-up dialog box or a window, the pop-up dialog box or window will be blocked, and Internet Explorer hosting the Web Publishing Tool may hang or crash. This issue was detected in Internet Explorer 11.

Workaround:

On Internet Explorer 11, select Internet options from the Tools menu, switch to the Security tab, remove the checkmark from Enable Protected Mode, and restart Internet Explorer.

LabVIEW 2017 N/A 05/22/2017
627783 Using TCP Open Connection with a Timeout of 0 can cause connection failures

When you specify a Timeout of 0 for TCP Open Connection, it will return error 56. However, in some cases, a connection can still be established. This will cause subsequent connection attempts to fail, even when they have a nonzero timeout.

Workaround:

Always use nonzero timeouts

LabVIEW 2010 SP1 N/A 05/22/2017
629032 Wiring a 2D array with an empty string to the property names input of the TDMS Set Properties function causes data for that channel to be unreadable

If a 2D array with an empty string is wired to the property names input of the TDMS Set Properties function, the TDMS Read function is unable to retrieve data from the channel with the empty name. The TDMS Read function will return error 1.

Workaround:

Do not include empty strings in the 2D array of property names

LabVIEW 2016 N/A 05/22/2017
629258 In some cases, reading from a corrupt TDMS file will delete the file from your machine

After opening a corrupt TDMS file and attempting to read from it, closing the reference to the TDMS file can delete the file from disk in some cases.

Workaround:

Open the TDMS file as read-only

LabVIEW 2010 SP1 LabVIEW 2018.0 05/22/2017
631422 Regenerate Channel Instances stop responding

In some situations, channel wires can hang LabVIEW when trying to regenerate channel instances. The hang will not end until LabVIEW is forced to close.

Workaround:

Open smaller subVIs containing channel wires first allowing the channels to regenerate. Once all of these are complete, open the calling VI. The smaller instances already regenerated their channel instances.

LabVIEW 2017 N/A 03/12/2018
631762 Using Export data to Excel on a Waveform Chart that contains an empty waveform can cause LabVIEW to crash

N/A

Workaround:

Do not plot empty waveforms or add a data point that is out of range that can be manually removed from the Excel sheet

LabVIEW 2016 N/A 05/22/2017
631802 Exporting typedef array of numerics to Excel may crash LabVIEW

When using the right-click menu option to export a non-empty, typedef numeric array's data to Excel, LabVIEW will crash.

Workaround:

N/A

LabVIEW 2010 SP1 LabVIEW 2018.0 05/22/2017
633309 Waveform graphs can resize at runtime

For very large floating point numbers in a waveform graph, the control can permanently resize itself in an attempt to fit the large numbers in the axis label

Workaround:

Use Automatic or Scientific as the format type for the Y Axis with large floating point numbers

LabVIEW 2017 N/A 05/22/2017
633648 LabVIEW crashes when replacing the Actor Framework library with a packed library

Building a packed library from the Actor Framework libraries and selecting "Replace with packed library..." in a project crashes LabVIEW.

Workaround:

N/A

LabVIEW 2016 N/A 01/23/2018
634015 Certain operations will not let the System Exec VI return on Windows 10

Certain commands, such as renaming a file, will cause the System Exec VI to indefinitely wait for a response on Windows 10. The IDE will continue to be responsive and the VI may be aborted. This will only occur with "Wait Until Completion" is set to True.

Workaround:

Set "Wait Until Completion" parameter to False

LabVIEW 2016 N/A 05/22/2017
634261 The Block Diagram.Get Image Scaled method displays subVIs as black rectangles if the image depth is less than 8.

Workaround:

Use a depth greater than 8

LabVIEW 2017 N/A 01/23/2018
634287 Incorrect behavior when creating a .NET Interop Assembly with typedefs

When you have multiple different typedefs with identical definitions (i.e, multiple numeric typedefs), only one of them is exported to a .NET typedef.

Workaround:

N/A

LabVIEW 2016 N/A 05/22/2017
634531 Template methods in a C&#43,&#43, DLL do not appear in the Function Name drop down list of the Call Library Function Node.

Some C&#43,&#43, DLLs include methods which are created from a template during compilation. These template methods will not appear in the list of function names when using the Call Library Function Node.

Workaround:

1. Create wrapper functions that call the template methods, then call the wrapper functions using the Call Library Function Node.

2. Manually specify the function prototype in the function name field of the Call Library Function Node.

LabVIEW 2015 SP1 N/A 04/18/2017
635510 Adding a diagram disable structure to a VI can cause the reported code coverage to be 100%

Workaround:

N/A

LabVIEW 2015 SP1 N/A 01/23/2018
638070 LabVIEW crashes when calling the Children[] Property Node in a VI with reentrancy set to "Shared clone reentrant execution."

N/A

Workaround:

Use the Search Variable Container VI instead of the Children[] Property Node. The regular expression and class inputs can help filter the results.

LabVIEW 2015 SP1 N/A 05/22/2017
639000 LabVIEW crashes when updating the radix of a numeric control on an Actor Core VI that is running

Workaround:

Update the display format of the control using a property node

LabVIEW 2015 SP1 N/A 01/23/2018
639524 Changing font to Application font can shrink constants inside of structures

In Japanese LabVIEW, changing the font of items on the block diagram from a non-default font to Application Font can cause constants within a structure to shrink

Workaround:

Select all items on the block diagram and press Ctrl&#43,1 to set them to Application Font again

LabVIEW 2014 SP1 N/A 05/22/2017
640089 DETT reports a reference leak when using the Open Data Storage express VI and Close Data Storage express VI

N/A

Workaround:

N/A

LabVIEW 2016 N/A 05/22/2017
640243 XY graph pointers do not copy correctly using Copy Data operation

When a graph annotation is displayed on an XY graph and the user copies the data using Data Operations>Copy Data, the image that is pasted does not properly display the pointers.

Workaround:

Use a waveform graph instead of an XY graph when possible

LabVIEW 2012 SP1 N/A 05/22/2017
641269 Interleaved TDMS Write with duplicate channel names fails to write data without returning an error

If you use the interleaved data layout with a TDMS Write, passing duplicate channel names in an array can cause some data to not be written to the TDMS file.

Workaround:

Use unique channel names in your array, or place the TDMS Write into a For Loop and index through each channel individually

LabVIEW 2010 SP1 N/A 05/22/2017
643107 Changing multiple plots' line styles does not work as expecting in XY graphs

In an XY graph with N data sets, changing the line style of data sets 2 through N will revert the line style for data set 1 to small dash

Workaround:

N/A

LabVIEW 2012 SP1 LabVIEW 2018.0 01/23/2018
647354 Opening a new shared variable connection can block reading from other connected variables

When attempting to open a shared variable connection that times out, read operations happening in parallel may stall until the time out occurs.

Workaround:

N/A

LabVIEW 2015 SP1 N/A 01/23/2018
648582 Express VIs cannot be created in certain localized versions of LabVIEW

Workaround:

N/A

LabVIEW 2015 SP1 LabVIEW 2018.0 01/23/2018
652898 LabVIEW crashes when attempting to open detailed help for an EXE

If the Help path property of a VI points to a PDF file, LabVIEW will crash when trying to open the detailed help of the EXE

Workaround:

N/A

LabVIEW 2015 SP1 N/A 01/23/2018
654057 When using clusters with a reference to the same control to register for multiple events, LabVIEW does not properly handle all events.

After bundling a control reference into a cluster and registering for different events using the same cluster, only the first event registered will be handled by the event structure.

Workaround:

Use separate Register for Events nodes for each event you want to register for, then bundle the event registration refnums into a cluster

LabVIEW 2017 N/A 01/23/2018
655865 The VI Method Save.For Previous fails to maintain the status of the "Separate compiled code from source file" attribute

When you use the Save.For Previous method on a VI with the "Separate compiled code from source file" attribute set to true, the saved VI will have this attribute set to false.

Workaround:

Saving for previous through the File menu works as expected

LabVIEW 2016 N/A 01/23/2018
656572 In some cases, some primitives may not properly display coercion dots when converting between integer representations

Workaround:

N/A

LabVIEW 2012 SP1 N/A 01/23/2018
664649 Accessing a DVR and deleting its reference in parallel can, in certain circumstances, cause LabVIEW to crash

Workaround:

N/A

LabVIEW 2016 LabVIEW 2018.0 01/23/2018
670209 Changing XControl state may lock XControl permanently

When changing XControl states in ways that conflict with pre-existing properties, it is possible to lock the state typedef and all of the property VIs. Unless the workaround applies, these VIs become permanently locked and the contained typedefs will be unable to update.

Workaround:

Right-click an instance of the state typedef that exists prior to the edit on non-locked VI and choose Review and Update from Typedef. This will fix all of the VIs, even locked VIs.

LabVIEW 2014 SP1 N/A 03/12/2018
673954 LabVIEW-built EXEs can crash when using channels that depend on type definitions.

Workaround:

N/A

LabVIEW 2017 LabVIEW 2018.0 01/23/2018
674079 Packed Libraries that have debugging enabled and use XNodes load slowly

Workaround:

N/A

LabVIEW 2013 SP1 N/A 01/23/2018
674968 LabVIEW does not automatically detect the LabWindows/CVI Runtime installer as a required dependency when building an installer from an EXE that requires the LabWindows/CVI Runtime

Workaround:

Manually include the LabWindows/CVI Runtime

LabVIEW 2017 N/A 01/23/2018
676013 LVMerge returns error 53 when the VI has a dependency on an XControl

Workaround:

N/A

LabVIEW 2017 N/A 01/23/2018
677020 Channel wires do not automatically update minor changes in core data type (Not A Bug)

Minor changes in non-typedef data types passed to a channel wire do not automatically update the channel wires. As an example, changing the name of a string contained in a cluster will not update the type: creating an indicator from the channel wire's downstream endpoint will still show the original names of the cluster.

This is not a bug. The situation is identical to using a queue, notifier, user event, or any other type-with-subtype that passes through a subVI terminal. If you have a queue of type cluster and you pass that queue into a subVI, then you change the field names of the upstream cluster, LabVIEW does not rewrite the terminal of the subVI. The only types that propagate changes to subVIs are typedefs. The endpoints of channels are subVIs and follow the same rules. LabVIEW does provide ways to request an update to the endpoints (see workaround).

Workaround:

Option 1. Right click on the channel endpoint and chose "Adapt To Element Type". This will rescript the endpoint to exactly match the core type. You will need to repeat this on the other endpoint(s) of the channel.

Option 2. Using a typedef or strict typedef as the channel's core type will ensure the types always match. Any changes made to the typedef will be made to the channel.

LabVIEW 2017 N/A 03/12/2018
678334 Changing the keyboard shortcut of the Bookmark Manager to Ctrl&#43,Shift&#43,3 does not launch the Bookmark Manager when the shortcut is pressed.

Workaround:

N/A

LabVIEW 2013 SP1 N/A 01/23/2018
678964 Nested XControls require recompile when built into Packed Project Libraries

When an XControl contains another XControl as part of its Facade.vi and is built into a Packed Project Library, it will error out and request a recompile. The recompile requires building the Packed Project Library a second time. The error will persist.

Workaround:

Either avoid nesting XControls or use their source directly and do not build them into a Packed Project Library

LabVIEW 2015 SP1 N/A 03/05/2018
678973 Tools->Synchronize with ni.com icon library fails in the LabVIEW Icon Editor

When attempting to synchronize the Icon Editor with the ni.com icon library, the operation fails.

Workaround:

Manually add the XML file found at http://www.ni.com/swf/iconlib/icons_filtered.xml

LabVIEW 2010 SP1 LabVIEW 2018.0 01/23/2018
684847 Nested PPL VIs cannot be found when debugging built executable

PPLs containing VIs from other PPLs can successfully build into an executable. If a debuggable version of the executable is built, LabVIEW will show the VIs as not found. This prevents debugging from seeing the block diagram for the nested VIs. They will continue to run as programmed.

Workaround:

N/A

LabVIEW 2016 N/A 03/14/2018
686080 Replacing ActorFramework.lvlib with a packed project library causes LabVIEW crash

Replacing the ActorFramework.lvlib with a built version of ActorFramework.lvlibp in any project puts LabVIEW into an unstable state and leads to a crash breaking Actor Framework.

Workaround:

Delete the AFDebug folder from\resource. Delete the ActorFramework folder from\vi.lib. Repair the LabVIEW installation.

LabVIEW 2017 SP1 N/A 03/12/2018
686273 Sound Output VIs can cause LabVIEW to freeze on Mac OS

Using Sound Output Stop followed by Sound Output Write can cause LabVIEW to freeze when developing for Mac OS.

Workaround:

Use the Clear Buffer VI and then re-initialize task to restart the sound rather than pause playback.

LabVIEW 2016 N/A 03/12/2018
686379 Objects flattened to XML may revert data to default value

When passing a class to the Flatten to XML VIs, data may be reverted to the default value rather than the value passed on when calling Unflatten from XML later.

Workaround:

Wire the output from a setter VI to the Unflatten to XML instead of a constant. Use other means to flatten the VI to a generic data type.

LabVIEW 2015 SP1 N/A 03/12/2018
686923 Bring to Front Invoke Node may not bring window to front

Some operating systems will bring the window in front of all LabVIEW windows but not any other windows. If LabVIEW is not the active window at the time of this call, the window may not come on top of other running windows.

Workaround:

Use operating specific calls to find the window and bring it in front of all other windows.

LabVIEW 2017 N/A 03/05/2018
688771 Cannot add CA-signed certificates to LabVIEW Web Services

LabVIEW Web Services only accept certificates created by the LabVIEW API. Valid certificates will not appear as options to add to web services pushing design decisions to use LabVIEW certificates, even when not the best solution..

Workaround:

Create a certificate with an identical name of the key for the signed certificate. Install the certificate selecting your root CA certificate. Create a new virtual host with the previously made certificate. Replace the LabVIEW generated private key with your correct private key in certstore.

LabVIEW 2017 SP1 N/A 03/12/2018
691608 Match Pattern primitive does not find matches if the Input String is empty.

Match Pattern function will return -1 as the offset past match if the input string is empty and the regular expression is ".*"

Workaround:

Use the Match Regular Expression function instead.

LabVIEW 2014 SP1 N/A 09/10/2018
701859 [Linux Red Hat 6.x] libniPythonInterface.so* symlinks are set to absolute paths

libniPythonInterface.so, libniPythonInterface.so.1 , libniPythonInterface.so.1.0.0 are linked in /usr/local/lib64/ with absolute paths instead of relative paths like the other .so files in the folder. This means that if the RTE is moved out of the root directory, then the EXE will not execute correctly.

Workaround:

Manually change the link targets for libniPythonInterface.so, libniPythonInterface.so.1, and libniPythonInterface.so.1.0.0 from specific file paths to relative paths. This should allow the RTE to execute in a non-root directory.

LabVIEW 2018 N/A 09/14/2018
703331 LabVIEW Built Application will crash at launch if contained in a folder that has any character not supported in the system codepage

If you use a non-native locale, a LabVIEW executable with a folder name that contains Unicode in its path will crash immediately when run.

Workaround:

Do not use any characters not supported in the legacy code page in the folder name containing the EXE.

LabVIEW 2014 SP1 N/A 09/10/2018
704478 Adding array manipulation functions between signed and unsigned numeric arrays incorrectly removes coercion dots

When wiring numeric arrays between unsigned and signed integers of the same bitness, introducing an array manipulation such as Transpose 2D array, Reverse 1D array, Array Subset, and Decimate will remove any coercion dots on subsequent indicators. However LabVIEW is still performing an in-place coercion to the data in the indicator.

The data itself is coerced correctly, but the coercion dot is not shown. This can affect the results from VI Analyzer.

Workaround:

N/A

LabVIEW 2010 SP1 N/A 09/14/2018
706182 Mass Compile causes LabVIEW crash

LabVIEW 2018 64-bit crashes during Mass Compile if Vision VIs are included, but the Vision Development Module is not installed.

Workaround:

Install the Vision dependencies that are required.

LabVIEW 2018 N/A 08/14/2018
706545 Clicking greyed out option of the Scale Legend when using a Waveform Chart causes LabVIEW to crash

If you add a Waveform Chart to the Front Panel (without wiring anything to it on the Block Diagram) and then expand the Legend to include more Plots, set the Waveform Chart to Stacked Plots, make the Scale Legend visible, and then expand the Scale Legend to show more empty or greyed out y-scales, when you try to select any of the buttons on the greyed out portion, LabVIEW will crash.

Workaround:

If you wire any 2D array (even an empty 2D array of doubles) to the Waveform Chart before setting the Waveform Chart to Stacked Plots, the crash will not occur.

LabVIEW 2014 SP1 N/A 09/14/2018
706578 LabVIEW RTE crashes when calling a VI that calls an ActiveX object

LabVIEW Run-Time Engine crashes when calling into a mass compiled VI that calls into an ActiveX object.

Workaround:

Register Utilities\InstrumenSimulation.dll as an ActiveX server before mass compiling the VI.

LabVIEW 2018 N/A 05/17/2019
715295 DataSocket Write VI with default timeout can hang before proceeding

When using the DataSocket Write VI with the default 0 second timeout (or wiring in a 0 second timeout), the VI may hang for 10 seconds before completing.

Workaround:

Wire in a short timeout of several ms to the DataSocket Write VI.

LabVIEW 2017 SP1 N/A 05/17/2019
723354 Remote debugged EXE returns error when attempting to save class changes

After remote debugging an executable that contains a class, clicking Save on the prompt results in an error.

Workaround:

1. Lock the classes you use before compiling an executable

2.Do not do remote debugging

3. Kill the process

LabVIEW 2018 N/A 05/17/2019
724157 [Linux] Build Specifications in Shipping examples may not be runnable by double-clicking

Most Linux shipping examples contain Build Specifications that default to a target output of 'main.exe'. This may not be directly runnable by double-clicking on a Linux OS.

Workaround:

1. Change the name of the 'Target destination' in the build specs and remove '.exe'

2. Change name of built executable and remove the '.exe'

3. Run 'Main.exe' via the command line

4. Delete the default build spec and create a new one

LabVIEW 2018 SP1 N/A 05/17/2019
727256 LabVIEW doesn't make a local copy of lvanlys.dll when building a PPL

When building a Packed Project Library that includes a VI in the LabVIEW analysis library (lvanlys.dll), a local copy is not made to the output directory.

Workaround:

Copy the lvanlys.dll (...National Instruments\LabVIEW 2018\resource) to the PPL output directory.

LabVIEW 2018 N/A 05/17/2019
727406 LabVIEW UDP broadcast is inconsistent across different OS's.

If the UDP Open VI has 0.0.0.0 wired to the Net Address terminal, the behavior varies with OS. Windows XP and NI ETS will send on all interfaces, while Windows Vista, Windows 7, VxWorks, and Linux will send on the default interface.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 8.6.1 N/A Feb 17, 2020
729952 Get Date/Time String does not work for dates beyond 2/5/2040

When trying to get a string for dates 2/6/2040 and beyond, the Get Date/Time String will instead provide an earlier, incorrect date.

Workaround:

Use the Format Date/Time String VI instead of Get Date/Time String

LabVIEW 2013 SP1 N/A 05/17/2019
732570 System decoration frame bleeds through system checkbox boolean text

In a System Tab Control with a System Decoration frame, the color bleeds through the boolean text of a system checkbox.

Workaround:

Use a normal button control configured as an indicator behind the boolean text, and resize it to match the width of the text.

LabVIEW 2016 N/A 05/17/2019
733608 Class VIs that call shared variables in a library in an auto-populating folder will not be loaded

If a VI in a class calls a shared variable that is in a library in an auto-populating folder, it will not find the shared variable when the project is loaded

Workaround:

Make the folder a snapshot instead of auto-populating and reopen the project

LabVIEW 8.6.1 LabVIEW 2014 Feb 18, 2020
758319 Selecting a newer version of a .NET assembly does not reload assembly

Changing a constructor from an old version of a .NET assembly to a newer version at edit time does not cause the new assembly to be loaded and consequently none of the new functionality is available.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2010 32-bit N/A Feb 14, 2020
782272 Some nodes may crash or yield incorrect/inconsistent results when Inlined

An Inline public methodVI calling a private-scope method VI, inlined into a non-class caller may give a runtime error when trying to call the private method from the inlined code in the non-class caller.

Workaround:

Do not try to Inline VIs with these nodes.

LabVIEW 2010 32-bit N/A Feb 17, 2020
783045 Updating the Labels of a Cluster Written to a Chart Does Not Update the Cluster Used for Chart History

Changing the Label of elements in a cluster written to the Waveform Chart does not update the label of the cluster when read from the Waveform Chart Data History Property.

Workaround:

Temporarily wire up a completely different data type to the Waveform chart indicator and then rewire the original cluster. The changes will now propagate to the Chart History.

LabVIEW 2009 32-bit LabVIEW 2015 Feb 14, 2020
783080 It is not possible to customize the Run-Time Shortcut menu of a 3D Graph

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2012 N/A Feb 17, 2020
783247 The MonthCalendar .NET control automatically resizes to the incorrect size when the VI is run

Workaround:

At the beginning of the code write to the Container Bounds property node "ContBounds" for the .NET container. While the code is running the calendar will have the right size

LabVIEW 2012 N/A Feb 14, 2020
783456 Double Numeric Slide can not be Set to 0 when it has Defined Limits with Mouse

A user can not slide a Double Numeric Slide to 0 when it has defined increment, maximum, and minimum properties. Instead of 0, a value very close to 0 will be entered ie: 5.55112E-16.

Workaround:

Do not set both defined maximum and minimum for the slide. Instead, change one of them to Inf or -Inf. Also a value of 0 can be entered into the digital slide.

LabVIEW 2012 N/A Feb 17, 2020
783469 Updates to Global Variables Not Visible when Remote Debugging a LabVIEW Built Stand-Alone Application

If the updates occured before connecting to the Remote Application with the debugger, the updates won't be visible. Updates to the Global Variable after connection with the debugger is establish will be visible.

Workaround:

Change the build specification for the stand-alone application to wait for debugger on launch, so no Global Variable updates can happen until a debug session is started.

LabVIEW 2012 SP1 N/A Feb 14, 2020
783573 The "do not save automatic changes" setting does not affect libraries

The "do not save automatic changes" options setting does not affect any type of library, including classes.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 8.0 N/A Feb 18, 2020
783680 Non-printable Characters in the Description of Will Corrupt LabVIEW Classes and Libraries

Non-printable characters can be inserted into the description of LabVIEW Classes and Libraries with the Description Property Node. This will corrupt the .lvclass or .lvlib file.

Workaround:

The .lvclass or .lvlib file can be opened in a text editor, and the description can be manually deleted to recover the files.

LabVIEW 2012 N/A Feb 18, 2020
783687 Editing large strict type definitions can take a long time to update

When large type definitions are updated, all instances in memory require an update. This update can take many minutes for very large type definitions.

Workaround:

Use smaller type definitions, or consider using LabVIEW classes to contain your type data.

LabVIEW 7.1.1 N/A Feb 18, 2020
783924 Listbox Control With Transparent Cell Background Does not Grey Disabled Item

Workaround:

Make the background color of the cells match the background of the panel, instead of making them transparent.

LabVIEW 2011 32-bit N/A Feb 17, 2020
788957 2GB file size limit of datalog files

The maximum size of datalog files is 2 GB.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 8.0 N/A Feb 17, 2020
792659 Getting an Entire Column of Data from a 2D Array in the MATLAB® Script Node Returns Only 1 Element

In the context of the MATLAB® Script Node, attempting to return an entire column of data from an array using a command like "column1 &#61, array2D(:,1)," returns only a single element. This same operation on a row "row1 &#61, array2D(1,:)," , returns the entire row successfully.

Workaround:

Transpose the array, and get the data in it's context as a row.

LabVIEW 2012 LabVIEW 2015 Feb 14, 2020
792730 Formula VI does not execute pow(x,y) function

Workaround:

Use the formula node to use the pow(x,y) function. If you need to change this programmatically, use the Power of X function in G code.

LabVIEW 2009 32-bit N/A Feb 17, 2020
795241 Adding or subtracting timestamps causes a conversion to double and precision loss

Workaround:

Cast the timestamps to clusters of U64 'seconds since epoch' and I64 'fractions of a second' before the operation and then cast back to timestamp after the operation

LabVIEW 2011 N/A Feb 17, 2020
819647 Deleting a second y-axis on a waveform graph with a cursor crashes LabVIEW

When using a waveform graph indicator, it is possible to crash LabVIEW with an access violation error 0xC0000005 at EIP&#61,0x00FE9E79 by creating two y-axis scales, creating a graph cursor, changing the cursor's associated y-axis, and then deleting the original y-axis scale.

Workaround:

Remove the scale from the waveform graph, remove the unwanted y-axis scale, then recreate the cursor.

LabVIEW 2013 SP1 LabVIEW 2016 Feb 17, 2020
819764 VI.Control Value.Set will Crash LabVIEW When Value Non-Variant Data is Used for Value Parameter

The crash will happen when VI.Control Value.Set is invoked upon a VI reference that has been opened by Open VI Reference.

Workaround:

Cast data to variant before wiring to Value parameter.

LabVIEW 2012 LabVIEW 2016 Feb 17, 2020
819932 It is not possible to save a VI with the name of another VI in memory, even if they are in different libraries

LabVIEW does not check the library namespace when determining if a VI is being saved with a name that is already in use. If a VI is in memory, it is not possible to save another VI with the same name in the same project even if they are in different libraries.

Workaround:

Close the other VIs with the same name so they are not in memory.

LabVIEW 2013 LabVIEW 2016 Feb 18, 2020
847135 Error 6 occurred at Create Folder in Create Directory Recursive.vi when building an application (EXE), shared library (DLL), source distribution or web service

When building a Build Specification, the build process fails with Error 6 at Create Folder in Create Directory Recursive.vi. This usually happens if the path one of the files generated by the build (temporarily during the build process or as part of the output) is too long. The operating system requires paths for files to be less than 255 characters.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 8.2.1 LabVIEW 2015 Feb 14, 2020
859021 When creating .NET assemblies in LabVIEW, 1-dimension arrays of doubles or strings are represented as 2-dimension arrays of rank 1

When creating .NET assemblies in LabVIEW, 1-dimension arrays of doubles or strings are represented as 2-dimension arrays of rank 1. This can create an issue when the assembly is used in Visual Studio 2015 which will not accept 2-dimensional arrays of rank 1.

Workaround:

Pass a 2D array in LabVIEW instead of a 1D array.

LabVIEW 2013 SP1 LabVIEW 2017 Feb 14, 2020
882096 Certain operations will not let the System Exec VI return on Windows 10

Certain commands, such as renaming a file, will cause the System Exec VI to indefinitely wait for a response on Windows 10. The IDE will continue to be responsive and the VI may be aborted. This will only occur with "Wait Until Completion" is set to True.

Workaround:

Set "Wait Until Completion" parameter to False

LabVIEW 2016 LabVIEW 2018 Feb 18, 2020
882110 Template methods in a C++ DLL do not appear in the Function Name drop down list of the Call Library Function Node.

Some C&#43,&#43, DLLs include methods which are created from a template during compilation. These template methods will not appear in the list of function names when using the Call Library Function Node.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2015 SP1 LabVIEW 2018 Feb 17, 2020
883542 Flattening an EXT representation numeric to JSON causes loss of precision

Workaround:

Use Format Into String followed by Flatten to JSON

LabVIEW 2013 SP1 LabVIEW 2018 Feb 18, 2020
885959 Waveform graphs can resize at runtime

For very large floating point numbers in a waveform graph, the control can permanently resize itself in an attempt to fit the large numbers in the axis label

Workaround:

Use Automatic or Scientific as the format type for the Y Axis with large floating point numbers

LabVIEW 2017 N/A Feb 17, 2020
886685 Calling the "Web Server: Server Active" property causes a small memory leak.

Calling the "Web Server: Server Active" property on any supported platform (including RT) creates a small memory leak.

Workaround:

Restart the application to allow the OS to reclaim the memory, or do not call this property often.

LabVIEW 2014 N/A Feb 19, 2020
889219 Type Defined Shared Variable not found in Executable

Workaround:

Disconnect from Type Def during the build.

LabVIEW 2010 32-bit N/A Feb 18, 2020
95055 Save for previous fails if file path is too long

Save for previous copies the folder being saved to a temp location, if the resulting file paths exceed the limit defined by the OS, the function fails.

Workaround:

Copy the folder being saved to the root directory to reduce the file path length and Save for Previous from that location.

LabVIEW 8.5 N/A 11/17/2009
953790 Session Timeout value from Create Session.vi should be I32

When a Web Session is created via the Create Session.vi, the default value for a time out is U32 but should be an I32 instead. The session is invalid if a value in the upper half of the U32 range is used.

Workaround:

Only use values in the I32 range.

LabVIEW 2016 N/A Jan 6, 2021
991959 Performance degradation in Channel Wire generation time

Generating Channel Wires causes performance degradation in LabVIEW 2020.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 LabVIEW 2020 SP1 Dec 2, 2020
997053 LabVIEW Crashes after Using Clean Up Diagram When Label with Bookmark Is Attached to Wire inside a Loop

LabVIEW crashes when the "Clean Up Diagram" on a VI has a label containing a bookmark that is positioned outside a loop but is attached to a wire inside the loop.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2019 LabVIEW 2022 Q3 Jan 6, 2021
997305 LabVIEW can crash or display incorrect text characters when "Use Unicode UTF-8" option enabled in Windows

On systems that have the Windows option "Beta: Use Unicode UTF-8 for worldwide language support" enabled in Region settings, LabVIEW can crash or display garbled text in some languages. To find the Region settings go to Control Panel > Region > Administrative > Change system locale...This option causes the system default code page to be UTF-8, which LabVIEW does not support.R&amp,D made changes in the LabVIEW 2020 f1 patch to prevent the crash, but some text will still display incorrectly in some languages.

Workaround:

Disable the "Beta: Use Unicode UTF-8 for worldwide language support" option in Windows.

LabVIEW 2020 LabVIEW 2020 f1 Aug 5, 2020
997357 Slowdown in loading PPLs in LabVIEW 2020 from TestStand

Calling LabVIEW 2020 built PPLs from TestStand causes slowdowns if the PPLs are loaded dynamically into memory and unloaded after the step executes.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2020 LabVIEW 2020 SP1 Dec 2, 2020
2619768 Duplicate Block Diagram Constant Differences in Compare VI Results

When comparing VIs, the same change to a block diagram constant can appear multiple times.

Workaround:

Fixed.

LabVIEW 2024 Q1 LabVIEW 2024 Q1 Patch 1 Mar 8, 2024
2643576 Incorrect VI Reference Opened by Open VI Reference When Created from an Existing Strict VI Reference

When passing a strict VI reference to the VI path parameter of Open VI Reference, the VI reference output forms incorrectly. The wire's data type is a strict VI reference, but the reference is non-strict. Passing this reference to functions that require a strict VI reference, such as Start Asynchronous Call, will result in a run-time error.

Workaround:

Fixed.

LabVIEW 2024 Q1 LabVIEW 2024 Q1 Patch 1 Mar 8, 2024
719917 Sound File Open for Write Can Produce Unexpected Values

Sound File Write Open.vi can produce unexpected values since it rounds sample rates down rather than to the nearest.

Workaround:

Fixed.

LabVIEW 2024 Q1 LabVIEW 2024 Q1 Patch 1 Mar 8, 2024
2645388 Building a Packed Library May Fail Due to Incorrect Path to .NET DLL

In LabVIEW 2024 Q1, building a packed library can fail because LabVIEW incorrectly resolves a relative path to a .NET DLL.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2024 Q1 LabVIEW 2024 Q3 Jul 17, 2024
221246 LabVIEW Does Not Propagate Type Definition Changes to Containers, Causing Unexpected Run-Time Behavior

After you change a type definition's qualified name (for example, by removing it from a class), LabVIEW may fail to apply such change to event refnums or other container data types that include that type definition. VIs that reference the affected container data type won’t show as broken, but may have unexpected run-time behavior

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2016 LabVIEW 2024 Q3 Jul 17, 2024
2597746 LabVIEW Fails to Create Probe for Cluster that Contains IMAQ Image

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2023 Q3 LabVIEW 2024 Q3 Jul 17, 2024
2663212 VI Block Diagram Wires Sometimes Draw Incorrectly on Ubuntu

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2024 Q1 LabVIEW 2024 Q3 Jul 17, 2024
2675593 LabVIEW (64-bit) Sometimes Gives Incorrect Results When Converting Timestamps to Strings with Fractional Seconds Exceeding 19 Digits

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2023 Q1 LabVIEW 2024 Q3 Jul 17, 2024
2682003 Resizing Loops Sometimes Moves Tunnels Unnecessarily

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2024 Q1 LabVIEW 2024 Q3 Jul 17, 2024
2687156 Compare VIs Does Not Report Differences in Window Transparency Values

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2023 Q1 LabVIEW 2024 Q3 Jul 17, 2024
2694996 Quick Drop Shortcuts Do Not Work When Placing VIs Shipped with LabVIEW

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2024 Q1 LabVIEW 2024 Q3 Jul 17, 2024
2695155 LabVIEW Can Display the Wrong Portion of a VI Block Diagram During Debugging When Diagram is Zoomed In

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2024 Q1 LabVIEW 2024 Q3 Jul 17, 2024
2707687 In Multi-Monitor Systems, LabVIEW Sometimes Fails to Display the Review and Update from Type Def. Dialog

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2023 Q3 LabVIEW 2024 Q3 Jul 17, 2024
2713392 Compare VIs Does Not Report Adding a Custom Run-time Menu on a Control as a Difference

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2016 LabVIEW 2024 Q3 Jul 17, 2024
2714418 LabVIEW Sometimes Cannot Display File Dialog After Creating Override Methods in a Class

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2023 Q3 LabVIEW 2024 Q3 Jul 17, 2024
2717959 LabVIEW Controls Do Not Receive Mouse Wheel Event with Ctrl Key Pressed

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2023 Q3 LabVIEW 2024 Q3 Jul 17, 2024
2731705 On Property and Invoke Nodes, the Right-click Help Menu for the Selected Property or Method is Missing

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2024 Q1 LabVIEW 2024 Q3 Jul 17, 2024
2742395 LabVIEW Crashes When Comparing VIs with Different Passwords

When comparing VIs that are protected with different passwords, LabVIEW crashes after you enter the passwords.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2024 Q1 LabVIEW 2024 Q3 Jul 17, 2024
2748388 Compare VIs Does Not Report Difference When Label Changes Attached Object

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2024 Q1 LabVIEW 2024 Q3 Jul 17, 2024
2752615 LabVIEW Editor Responds Slowly with Navigation Window Open and Block Diagram Zoomed

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2024 Q1 LabVIEW 2024 Q3 Jul 17, 2024
2767151 Mass Compile Does Not Update Cache for Some VIs Installed in LVAddons

Mass compile doesn't update the compile cache for VIs installed in the shared LVAddons folder if the VIs are in read-only LLBs. Without an updated cache, TestStand cannot run the VIs using the LabVIEW Run-Time Engine.

Workaround:

There is currently no known workaround for this issue.

LabVIEW 2024 Q1 LabVIEW 2024 Q3 Jul 17, 2024
2781966 Unexpected Save Dialogs When Maintaining Projects in Older Save Version

LabVIEW may prompt you to save changes when editing VIs in a project maintained in an older version. For example, using DQMH for operations such as creating Private Events or validating a DQMH module will trigger a prompt to save VIs, indicating that the VI's source save version has changed. Workaround:

There is currently no known workaround for this issue.

LabVIEW 2024 Q3 N/A Jul 17, 2024
2785983 LabVIEW Sometimes Prompts You to Save Unedited VIs

LabVIEW may prompt you to save VIs that reference shared libraries, including some VIs in the Electrical Power Toolkit. If you do not save the VIs, deployment to Real-Time targets can fail.

Workaround:

Save the VIs when prompted. You may need to modify the VI permissions or run LabVIEW as an administrator to save the VIs.

LabVIEW 2024 Q3 N/A Jul 17, 2024
2786419 Palette Categories Are Visible Even When Empty

All the palette categories are visible by default. Workaround: On a pinned palette, go to Customize > Change Visible Palettes, and select or deselect palettes to show or hide them. Fixed in LabVIEW 2024 Q3 Patch 1.

LabVIEW 2024 Q3 LabVIEW 2024 Q3 Core Patch 1 Jul 17, 2024
2798144 MATLAB Script Nodes Break VIs

VIs containing MATLAB Script Nodes are broken because the script support DLL is not found.

Workaround:

Fixed in LabVIEW 2024 Q3 Patch 1.

LabVIEW 2024 Q3 LabVIEW 2024 Q3 Core Patch 1 Jul 17, 2024
2799931 Command Prompt Window Appears Briefly During Launch of LabVIEW on Windows

Workaround:

Fixed in LabVIEW 2024 Q3 Patch 1.

LabVIEW 2024 Q3 LabVIEW 2024 Q3 Core Patch 1 Jul 17, 2024
2800868 LabVIEW Numeric Control Fails to Paste Values Copied from Microsoft Outlook or Word

Workaround:

Fixed in LabVIEW 2024 Q3 Patch 1.

LabVIEW 2024 Q1 LabVIEW 2024 Q3 Core Patch 1 Aug 7, 2024
2811695 LabVIEW Class Becomes Corrupted After Editing Private Data Control and Saving from Unsaved Changes Dialog

Workaround:

Fixed in LabVIEW 2024 Q3 Patch 1.

LabVIEW 2024 Q3 LabVIEW 2024 Q3 Core Patch 1 Aug 7, 2024
812117 Find Parallelizable Loops Does Not Analyze VIs Under Targets

Workaround:

There is currently no known workaround for this issue.