VI Server Property Information
|
Property ID
|
778ED40A
|
Scope
|
VI Scripting
|
Data Name
|
IgnoreReset
|
Short Name*
|
IgnoreReset
|
Long Name*
|
Ignore FPGA Reset Method
|
* Displayed here in English. Short and Long names appear in the language of the LabVIEW IDE.
|
Owning Class ID
|
16522
|
Owning Class Name
|
FeedbackNode Class
|
Data Type
|
Boolean data type
|
Property Node
|
|
Available in Real-Time Operating System | Yes |
Available in Run-Time Engine | Yes |
Loads the block diagram into memory | No |
Loads the front panel into memory | No |
Need to authenticate before use | No |
Permissions | Read/Write |
Remote access allowed | Yes |
Settable when the VI is running | No |
Gets or sets whether this Feedback Node initializes if the FPGA VI resets. If TRUE, this node does not initialize if the FPGA VI resets. This node initializes the next time you download the FPGA VI to the FPGA target. This property applies only when the Feedback Node is deployed on an FPGA target. This property can have a value of TRUE only when the initialization style of the Feedback Node is to initialize on compile or load.
If you write a value of TRUE, ensure the application does not depend on the value this Feedback Node returns on the first call after resetting the FPGA VI.
Uses
History
Version
|
Change(s)
|
|
More info to come.
|
See Also