| VI Server Property Information
|
| Property ID
|
633B00B
|
| Scope
|
Basic Development Environment
|
| Data Name
|
OutOfRngAction
|
| Short Name*
|
RespToValOutLimits
|
| Long Name*
|
Response to Value Outside Limits
|
| * Displayed here in English. Short and Long names appear in the language of the LabVIEW IDE.
|
| Owning Class ID
|
17
|
| Owning Class Name
|
Numeric Class
|
| Data Type
|
Numeric Cluster TypeDef data type
|
| Property Node
|
|
| Available in Real-Time Operating System | Yes |
| Available in Run-Time Engine | Yes |
| Loads the block diagram into memory | No |
| Loads the front panel into memory | No |
| Need to authenticate before use | No |
| Permissions | Read/Write |
| Remote access allowed | Yes |
| Settable when the VI is running | Yes |
Reads or writes the response to values outside the specified limits for maximum, minimum, and increment.
You can select from the following options:
| 0
|
Ignore—LabVIEW does not change or flag invalid values.
|
| 1
|
Coerce (to nearest)
|
| 2
|
Coerce up
|
| 3
|
Coerce down
|
This property is similar to the Response to value outside limits option on the Data Entry page of the Properties dialog box.
Elements
| Name
|
Description
|
| Response to Value Outside Limits:Minimum
|
Response to values outside the limits for the minimum value. Valid values include 0 (Ignore) and 1 (Coerce).
|
| Response to Value Outside Limits:Maximum
|
Response to values outside the limits for the maximum value. Valid values include 0 (Ignore) and 1 (Coerce).
|
| Response to Value Outside Limits:Increment
|
Response to values outside the limits for the increment value. Valid values include 0 (Ignore), 1 (Coerce to nearest), 2 (Coerce up), and 3 (Coerce down).
|
Uses
History
| Version
|
Change(s)
|
|
More info to come.
|
See Also
External Links