Jump to content

NumericConstant class/Fixed-Point Representation.Bits.Signed property: Difference between revisions

From LabVIEW Wiki
m Category reorg
Updated for LabVIEW 2020
 
(2 intermediate revisions by the same user not shown)
Line 2: Line 2:
| classid = 16389
| classid = 16389
| propertyid = 5DCFC02
| propertyid = 5DCFC02
| scope=private
| scope=script
| dataname = FXP Signed
| dataname = FXP Signed
| shortname = FXPSigned
| shortname = FXPSigned
Line 9: Line 9:
| datatype = Boolean
| datatype = Boolean
| propertynodeimage = NumericConstant-Fixed-Point Representation-Bits-Signed.png
| propertynodeimage = NumericConstant-Fixed-Point Representation-Bits-Signed.png
| availableinrealtime = Yes
| availableinruntime = Yes
| loadsbd = No
| loadsfp = Yes
| needsauthentication = No
| permissions = Read/Write
| permissions = Read/Write
| remoteallowed = Yes
| settablewhenrunning = No
|}}
|}}
{{TOCright}}
{{TOCright}}


Reads or writes whether the fixed-point value is a signed value. FALSE means signed. Using this property with a non-fixed-point number will result in an error.


== Uses ==
== Uses ==
Line 18: Line 26:


== History ==
== History ==
{{ambox|text=History information is needed.  What changes have occurred over previous versions?}}
{| class="wikitable"
{| class="wikitable"
! Version
! Version
! Change(s)
! Change(s)
|-
|-
|[[File:LV2018.png|frameless|border|64x64px|LabVIEW 2018|link=LabVIEW 2018]]
|[[File:LV2020.png|frameless|border|64x64px|LabVIEW 2020|link=LabVIEW 2020]]
|More info to come.
| In [[LabVIEW 2020]] this property was changed from [[VI Server#Private|Private]] to [[VI Server#VI Scripting|VI Scripting]].
|}
|}
== See Also ==
== See Also ==
{{ambox|text=Add links to internal wiki pages that would also help.}}
{{ambox|text=Add links to internal wiki pages that would also help.}}
Line 32: Line 40:
{{ambox|text=Add links to external resources that would also help.}}
{{ambox|text=Add links to external resources that would also help.}}


[[Category:VI Scripting Property]]
[[Category:VI Server Property]]
[[Category:VI Server Property]]

Latest revision as of 19:13, 15 June 2020

VI Server Property Information
Property ID 5DCFC02
Scope VI Scripting
Data Name FXP Signed
Short Name* FXPSigned
Long Name* Fixed-Point Representation:Bits:Signed
* Displayed here in English. Short and Long names appear in the language of the LabVIEW IDE.
Owning Class ID 16389
Owning Class Name NumericConstant Class
Data Type Boolean data type

Boolean

Property Node Fixed-Point Representation:Bits:Signed
Available in Real-Time Operating SystemYes
Available in Run-Time EngineYes
Loads the block diagram into memoryNo
Loads the front panel into memoryYes
Need to authenticate before useNo
PermissionsRead/Write
Remote access allowedYes
Settable when the VI is runningNo

Reads or writes whether the fixed-point value is a signed value. FALSE means signed. Using this property with a non-fixed-point number will result in an error.

Uses

History

Version Change(s)
LabVIEW 2020 In LabVIEW 2020 this property was changed from Private to VI Scripting.

See Also

External Links