Jump to content

Application class/Application.All VIs In Memory property: Difference between revisions

From LabVIEW Wiki
Started page
 
Limitations: Add a section to describe what is not included
 
(2 intermediate revisions by one other user not shown)
Line 16: Line 16:
{{TOCright}}
{{TOCright}}


Returns a list of VIs in memory for the specified [[Application instance|application instance]]. This property returns an error if you wire a remote application reference to the '''reference''' input. For a remote application, use the [[Application class/Exported VIs in Memory property]] to return a list of exported VIs.
Returns a list of VIs in memory for the specified [[Application instance|application instance]]. This property returns an error if you wire a remote application reference to the '''reference''' input. For a remote application, use the [[Application class/Exported VIs in Memory property|Exported VIs in Memory property]] to return a list of exported VIs.
 
'''Note'''  If you have multiple application instances open simultaneously, this property returns only the VIs in memory in the specified application instance. LabVIEW creates a new application instance each time you open a LabVIEW project or target for a LabVIEW project.


<table class="Borderless">|-
<td class="Icon"><img src="note.gif">
<td>'''Note'''  If you have multiple application instances open simultaneously, this property returns only the VIs in memory in the specified application instance. LabVIEW creates a new application instance each time you open a LabVIEW project or target for a LabVIEW project.
|}
== Uses ==
== Uses ==
{{ambox|text=Specific use cases for this property.}}
{{ambox|text=Specific use cases for this property.}}
== Limitations ==
Dependencies and non-public members of [[PPL]]s are not included in the list, even if they are accessible through their [[fully qualified name]].


== History ==
== History ==
Line 34: Line 35:
|More info to come.
|More info to come.
|}
|}
== See Also ==
 
== See also ==
{{ambox|text=Add links to internal wiki pages that would also help.}}
{{ambox|text=Add links to internal wiki pages that would also help.}}


== External Links ==
== External links ==
{{ambox|text=Add links to external resources that would also help.}}
{{ambox|text=Add links to external resources that would also help.}}


[[Category:Property]]
[[Category:VI Server Property]]
[[Category:VI Server Property]]

Latest revision as of 06:16, 22 April 2026

VI Server Property Information
Property ID 1C
Scope Basic Development Environment
Data Name App.AllVIs
Short Name* App.AllVIs
Long Name* Application:All VIs In Memory
* Displayed here in English. Short and Long names appear in the language of the LabVIEW IDE.
Owning Class ID 1
Owning Class Name Application Class
Data Type String Array data type

String Array

Property Node Application:All VIs In Memory
Available in Real-Time Operating SystemYes
Available in Run-Time EngineYes (Read Only)
PermissionsRead Only
Remote access allowedNo

Returns a list of VIs in memory for the specified application instance. This property returns an error if you wire a remote application reference to the reference input. For a remote application, use the Exported VIs in Memory property to return a list of exported VIs.

Note If you have multiple application instances open simultaneously, this property returns only the VIs in memory in the specified application instance. LabVIEW creates a new application instance each time you open a LabVIEW project or target for a LabVIEW project.

Uses

Limitations

Dependencies and non-public members of PPLs are not included in the list, even if they are accessible through their fully qualified name.

History

Version Change(s)
LabVIEW 2018 More info to come.

See also