| Line 2: | Line 2: | ||
| classid = 16389 | | classid = 16389 | ||
| propertyid = 5DCFC03 | | propertyid = 5DCFC03 | ||
| scope= | | scope=script | ||
| dataname = FXP WL | | dataname = FXP WL | ||
| shortname = FXPWordLength | | shortname = FXPWordLength | ||
| Line 9: | Line 9: | ||
| datatype = I32 | | datatype = I32 | ||
| propertynodeimage = NumericConstant-Fixed-Point Representation-Bits-Word Length.png | | propertynodeimage = NumericConstant-Fixed-Point Representation-Bits-Word Length.png | ||
| availableinrealtime = Yes | |||
| availableinruntime = Yes | |||
| loadsbd = No | |||
| loadsfp = Yes | |||
| needsauthentication = No | |||
| permissions = Read/Write | | permissions = Read/Write | ||
| remoteallowed = Yes | |||
| settablewhenrunning = No | |||
|}} | |}} | ||
{{TOCright}} | {{TOCright}} | ||
Reads or writes the word length of the fixed-point value. FALSE means signed. Using this property with a non-fixed-point numeric will result in an error. | |||
== Uses == | == Uses == | ||
| Line 18: | Line 26: | ||
== History == | == History == | ||
{| class="wikitable" | {| class="wikitable" | ||
! Version | ! Version | ||
! Change(s) | ! Change(s) | ||
|- | |- | ||
|[[File: | |[[File:LV2020.png|frameless|border|64x64px|LabVIEW 2020|link=LabVIEW 2020]] | ||
| | | In [[LabVIEW 2020]] this property was changed from [[VI Server#Private|Private]] to [[VI Server#VI Scripting|VI Scripting]]. | ||
|} | |} | ||
== See Also == | == See Also == | ||
{{ambox|text=Add links to internal wiki pages that would also help.}} | {{ambox|text=Add links to internal wiki pages that would also help.}} | ||
| Line 32: | Line 40: | ||
{{ambox|text=Add links to external resources that would also help.}} | {{ambox|text=Add links to external resources that would also help.}} | ||
[[Category: Property]] [[Category:VI Server Property]] | [[Category:VI Scripting Property]] | ||
[[Category:VI Server Property]] | |||
Latest revision as of 19:17, 15 June 2020
| VI Server Property Information | |
|---|---|
| Property ID | 5DCFC03 |
| Scope | VI Scripting |
| Data Name | FXP WL |
| Short Name* | FXPWordLength |
| Long Name* | Fixed-Point Representation:Bits:Word Length |
| * Displayed here in English. Short and Long names appear in the language of the LabVIEW IDE. | |
| Owning Class ID | 16389 |
| Owning Class Name | NumericConstant Class |
| Data Type | I32 data type |
| Property Node | |
| Available in Real-Time Operating System | Yes |
| Available in Run-Time Engine | Yes |
| Loads the block diagram into memory | No |
| Loads the front panel into memory | Yes |
| Need to authenticate before use | No |
| Permissions | Read/Write |
| Remote access allowed | Yes |
| Settable when the VI is running | No |
Reads or writes the word length of the fixed-point value. FALSE means signed. Using this property with a non-fixed-point numeric will result in an error.