Revision as of 18:35, 6 April 2020
| VI Server Property Information
|
| Property ID
|
6332028
|
| Scope
|
Basic Development Environment
|
| Data Name
|
FPB.URL
|
| Short Name*
|
BindingPath
|
| Long Name*
|
Data Binding:Path
|
| * Displayed here in English. Short and Long names appear in the language of the LabVIEW IDE.
|
| Owning Class ID
|
6
|
| Owning Class Name
|
Control Class
|
| Data Type
|
String data type
|
| Property Node
|
|
| Available in Real-Time Operating System | Yes |
| Available in Run-Time Engine | Yes |
| Loads the block diagram into memory | No |
| Loads the front panel into memory | No |
| Need to authenticate before use | No |
| Permissions | Read/Write |
| Remote access allowed | Yes |
| Settable when the VI is running | Yes |
Reads or writes the NI Publish-Subscribe Protocol (NI-PSP) URL to which the control is connected. To write this property, you must bind the control to the PSP URL before you begin writing.
| Note If the control is bound to a project item instead of a PSP URL and you attempt to write this property, this property returns an error.
|
To bind the control to a PSP URL, use the Bind to Network Path method while the VI is not running.
Uses
History
| Version
|
Change(s)
|
|
More info to come.
|
See Also
External Links