LabVIEW configuration file/Execution System
< LabVIEW configuration file(Redirected from LabVIEW configuration file.Execution System)
This is a list of LabVIEW ini File settings relating to the Execution System.
allowMultipleInstances
Example | allowMultipleInstances=FALSE
|
---|---|
Description | Enables running multiple instances of the application at the same time.[1] |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | FALSE |
LabVIEW Versions | |
OS's Supported | |
Notes |
ESys.StdNParallel
Example | ESys.StdNParallel=5
|
---|---|
Description | Defines the number of threads to start in each execution system and priority level. |
Datatype | Integer |
Permitted Values | -1 to 8 (see notes) |
Default Value | 1 |
LabVIEW Versions | |
OS's Supported | |
Notes |
|
hideRootWindow
Example | hideRootWindow=FALSE
|
---|---|
Description | Hides the application's front panel window and removes any taskbar icons when running the executable.[2] |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | FALSE |
LabVIEW Versions | |
OS's Supported | |
Notes |
runAsService
Example | runAsService=True
|
---|---|
Description | This key tells the LabVIEW Run-Time Engine to ignore the Windows WM_ENDSESSION message that is sent when a user logs off! Use this key when your LabVIEW application is configured to run as a Windows service and has a user interface (service allowed to interact with desktop). The key prevents your LabVIEW application to quit when a user logs off. |
Datatype | Boolean |
Permitted Values | True or False |
Default Value | False |
LabVIEW Versions | |
OS's Supported | |
Notes | See also following thread: Creating a Windows NT Service Using LabVIEW: [1] |
ESys.xxx.yyyy
Example: Various ...
References
- ↑ Run Multiple Instances of a LabVIEW Executable Simultaneously (National Instruments)
- ↑ Running a LabVIEW Executable as a Background Process (National Instruments)