Jump to content

ConnectorPane class

From LabVIEW Wiki
Revision as of 23:32, 26 August 2019 by Q (talk | contribs) (Started page)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
VI Server Class Information
Return to VI Server Class Hierarchy
Class Name class
Class ID {{{1}}}
Scope
Class Inheritance

This class is a top-level class.

Class Children

This class has no children.


The ConnectorPane class is a class in the VI Server Class Hierarchy, (see also VI Server).

Properties

Show/Hide ConnectorPane Properties Table

Legend
R/WReadable/Writable Permissions
RTEAvailable in the Run-Time Engine
Basic Development Environment
VI Scripting
Private
Deprecated
ConnectorPane Properties Table
Property ID Short Name (English) Description R/W RTE
239A8403 Ctrls() Gets the controls hooked to the connector. R X
239A8402 IconVis Makes the icon or the connector pane visible. R/W X
239A8401 NumConns Returns the number of connection terminals in the connector pane R X
239A8400 Pattern Assigns or gets the connector pane pattern for a VI. Valid values are 4800 to 4835. R/W X
239A8404 TermBnds() Returns an array of terminal bounds for the referenced connector pane. The bounds for each terminal are represented as a cluster of integers that indicate the position of each edge of the terminal rectangle.

The array elements are in terminal order as defined in the Connector Pane Pattern Reference VI for each connector pane pattern.

R X
239A8405 WiringRules() Sets or returns an array of the wiring rules for each terminal on a connector pane. R/W

Methods

Show/Hide ConnectorPane Methods Table

Legend
RTEAvailable in the Run-Time Engine
Basic Development Environment
VI Scripting
Private
Deprecated
ConnectorPane Methods Table
Method ID Short Name (English) Description RTE
239A8000 AssignCtrlToTerm Assigns a front panel control to a connector pane terminal of the VI.

You can use this method to configure the connector panes of a target VI using VI Scripting.

239A8003 DiscAllTerms Disconnects all connector pane terminals from controls and indicators.
239A8002 DiscTerm Disconnects a connector pane terminal from a control or an indicator.
239A8005 FlipHoriz Flips the connector pane horizontally.
239A8006 FlipVert Flips the connector pane vertically.
239A8004 Rot90 Rotates the connector pane counter-clockwise by 90 degrees.
239A8007 GetWiringRule Gets the wiring properties of a connector pane terminal.

Possible values include Invalid Wire Rule, Required, Recommended, Optional, and Dynamic Dispatch.

239A8001 SetWireRule Sets the wiring properties of a connector pane terminal.

Events

No Events for this class.

History

Version Change(s)
LabVIEW 2018 More info to come.

See Also