LabVIEW configuration file/Block Diagram
Template:LabVIEW configuration back This is a list of LabVIEW ini File settings relating to Block Diagram behaviour.
autoWireMax
Example | autoWireMax=24
|
---|---|
Description | Maximum distance between nodes for autowiring to be active |
Datatype | Integer |
Permitted Values | 1 to 232 |
Default Value | 16 |
LabVIEW Versions | |
OS's Supported | |
Notes | This setting is only effective if enableAutoWire is set to TRUE |
autoWireMin
Example | autoWireMin=8
|
---|---|
Description | Minimum distance between nodes for autowiring to be active |
Datatype | Integer |
Permitted Values | 1 to 232 |
Default Value | 4 |
LabVIEW Versions | |
OS's Supported | |
Notes | This setting is only effective if enableAutoWire is set to TRUE |
copyDeleteFPDCOFromFPTerm
Example | copyDeleteFPDCOFromFPTerm=TRUE
|
---|---|
Description | Delete front panel terminals from diagram |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | FALSE |
LabVIEW Versions | |
OS's Supported | |
Notes | None |
copyDeleteFPDCOFromFPTerm
Example: copyDeleteFPDCOFromFPTerm=TRUE
Description: Delete front panel terminals from diagram
Datatype: Boolean
Permitted Values: TRUE
or FALSE
Default Value: FALSE
LabVIEW Versions: 4.x, 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes: None
enableAutoWire
Example: enableAutoWire=FALSE
Description: Enable Auto Wiring
Datatype: Boolean
Permitted Values: TRUE
or FALSE
Default Value: TRUE
LabVIEW Versions: 6.x, 7.x, 8.x
OS's Supported:
Notes: None
funkyErrClustWire
Example: funkyErrClustWire=FALSE
Description: Change Error Cluster wires color from the standard cluster pink to a more appealing brown/green color
Datatype: Boolean
Permitted Values: TRUE
or FALSE
Default Value: LabVIEW 5.1, 6.x, 7.x: FALSE
, LabVIEW 8.x: TRUE
LabVIEW Versions: 5.1, 6.x, 7.x, 8.x
OS's Supported:
Notes: None
inlineSubVIEnabled
Example: inlineSubVIEnabled=FALSE
Description: Allows the context menu item "Inline SubVI" on any SubVI which inserts the code directly into the block diagram containing the SubVI.
Datatype: Boolean
Permitted Values: TRUE
or FALSE
Default Value: FALSE
LabVIEW Versions: 6.x, 7.x, 8.x
OS's Supported:
Notes: None
maxUndoSteps
Example: maxUndoSteps=50
Description: Maximum undo steps per VI
Datatype: Integer
Permitted Values: 1 to 232
Default Value: 8
LabVIEW Versions: 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes: None
showSubVIName
Example: showSubVIName=TRUE
Description: Show subVI names when dropped
Datatype: Boolean
Permitted Values: TRUE
or FALSE
Default Value: FALSE
LabVIEW Versions: 4.x, 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes: None
showTipStringsOnTerms
Example: showTipStringsOnTerms=FALSE
Description: Show tip-strips over terminals
Datatype: Boolean
Permitted Values: TRUE
or FALSE
Default Value: TRUE
LabVIEW Versions: 4.x, 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes: None
showWireDots
Example: showWireDots=TRUE
Description: Show dots at wire junctions
Datatype: Boolean
Permitted Values: TRUE
or FALSE
Default Value: FALSE
LabVIEW Versions: 7.x, 8.x
OS's Supported:
Notes: None
showWireGuides
Example: showWireGuides=FALSE
Description: None
Datatype: Boolean
Permitted Values: TRUE
or FALSE
Default Value: TRUE
LabVIEW Versions: 4.x, 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes: None
structuresFadeToDiagramBeneath
Example: structuresFadeToDiagramBeneath=FALSE
Description: Makes the diagram of structures semi-transparent so that you can see objects behind them.
Datatype: Boolean
Permitted Values: TRUE
or FALSE
Default Value: TRUE
LabVIEW Versions: 6.x, 7.x, 8.x
OS's Supported:
Notes: Enabling this setting will slow down the development environment on large Block Diagrams
transparentBDLabels
Example: transparentBDLabels=TRUE
Description: Use transparent name labels
Datatype: Boolean
Permitted Values: TRUE
or FALSE
Default Value: FALSE
LabVIEW Versions: 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes: None
viCaptionTipStrings
Example: viCaptionTipStrings=FALSE
Description: Use control captions for subVI tip-strips
Datatype: Boolean
Permitted Values: TRUE
or FALSE
Default Value: TRUE
LabVIEW Versions: 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes: None
viTitleInPalettes
Example: viTitleInPalettes=TRUE
Description: Use Window Titles in function palettes
Datatype: Boolean
Permitted Values: TRUE
or FALSE
Default Value: FALSE
LabVIEW Versions: 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes: None