LabVIEW configuration file/Block Diagram: Difference between revisions
Appearance
Pbrooks100 (talk | contribs) Added FancyFPTerms entry - sited source: http://forums.lavag.org/FancyFPTerms-in-LabVIEWini-t725.html |
Added Section "UseNumbersForNewVIIcons" |
||
Line 282: | Line 282: | ||
| OS4 = u | | OS4 = u | ||
| notes = None | | notes = None | ||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = UseNumbersForNewVIIcons | |||
| example = UseNumbersForNewVIIcons=FALSE | |||
| datatype = b | |||
| description = Tells LabVIEW whether to automatically include a number (1-9) in the lower-right corner of each new VI's icon. | |||
| permitted_values = TRUE or FALSE | |||
| default = TRUE | |||
| LV1 = 8 | |||
| LV2 = | |||
| LV3 = | |||
| LV4 = | |||
| LV5 = | |||
| LV6 = | |||
| OS1 =w | |||
| OS2 =m | |||
| OS3 =l | |||
| OS4 = | |||
| notes = LabVIEW 8.6 only. This key replaces [[#UseNumbersForNewVIIconsInLibs|UseNumbersForNewVIIconsInLibs]] from LabVIEW 8.5. | |||
}} | }} | ||
{{ labviewconfigurationkey | {{ labviewconfigurationkey | ||
Line 287: | Line 306: | ||
| example = UseNumbersForNewVIIconsInLibs=FALSE | | example = UseNumbersForNewVIIconsInLibs=FALSE | ||
| datatype = b | | datatype = b | ||
| description = Tells LabVIEW whether to automatically | | description = Tells LabVIEW whether to automatically include a number (1-9) in the lower-right corner of each new VI's icon for VIs created inside libraries (.lvlib, .lvclass, .xctl, .lvsc, etc). | ||
| permitted_values = TRUE or FALSE | | permitted_values = TRUE or FALSE | ||
| default = TRUE | | default = TRUE | ||
Line 300: | Line 319: | ||
| OS3 =l | | OS3 =l | ||
| OS4 = | | OS4 = | ||
| notes = LabVIEW 8.5 only | | notes = LabVIEW 8.5 only. This key was replaced by [[#UseNumbersForNewVIIcons|UseNumbersForNewVIIcons]] in LabVIEW 8.6. | ||
}} | }} | ||
{{ labviewconfigurationkey | {{ labviewconfigurationkey |
Revision as of 22:29, 27 August 2008
This is a list of LabVIEW ini File settings relating to Block Diagram behaviour.
allowDragDropFromFileDlg
Example | allowDragDropFromFileDlg=TRUE
|
---|---|
Description | Enables drag and drop functionality from the file dialog to the block diagram of a vi |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | FALSE |
LabVIEW Versions | |
OS's Supported | |
Notes | This functionality existed in LV 5.0 -> LV 7.1, was removed in LV 8.x, and added back in as an ini setting in 8.5 |
autoWireMax
Example | autoWireMax=24
|
---|---|
Description | Maximum distance between nodes for autowiring to be active |
Datatype | Integer |
Permitted Values | 1 to 232 |
Default Value | 16 |
LabVIEW Versions | |
OS's Supported | |
Notes | This setting is only effective if enableAutoWire is set to TRUE |
autoWireMin
Example | autoWireMin=8
|
---|---|
Description | Minimum distance between nodes for autowiring to be active |
Datatype | Integer |
Permitted Values | 1 to 232 |
Default Value | 4 |
LabVIEW Versions | |
OS's Supported | |
Notes | This setting is only effective if enableAutoWire is set to TRUE |
copyDeleteFPDCOFromFPTerm
Example | copyDeleteFPDCOFromFPTerm=TRUE
|
---|---|
Description | Delete front panel terminals from diagram |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | FALSE |
LabVIEW Versions | |
OS's Supported | |
Notes | None |
enableAutoWire
Example | enableAutoWire=FALSE
|
---|---|
Description | Enable Auto Wiring |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | TRUE |
LabVIEW Versions | |
OS's Supported | |
Notes | None |
FancyFPTerms
Example | FancyFPTerms=FALSE
|
---|---|
Description | Place front panel terminals as icons |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | (Depends on LV Version) |
LabVIEW Versions | |
OS's Supported | |
Notes | http://forums.lavag.org/FancyFPTerms-in-LabVIEWini-t725.html |
funkyErrClustWire
Example | funkyErrClustWire=FALSE
|
---|---|
Description | Change Error Cluster wires color from the standard cluster pink to a more distinctive brown/green color |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | LabVIEW 5.1, 6.x, 7.x: FALSE, LabVIEW 8.x: TRUE |
LabVIEW Versions | |
OS's Supported | |
Notes | None |
inlineSubVIEnabled
Example | inlineSubVIEnabled=FALSE
|
---|---|
Description | Allows the context menu item "Inline SubVI" on any SubVI which inserts the code directly into the block diagram containing the SubVI. |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | FALSE |
LabVIEW Versions | |
OS's Supported | |
Notes | None |
maxUndoSteps
Example | maxUndoSteps=50
|
---|---|
Description | Maximum undo steps per VI |
Datatype | Integer |
Permitted Values | 1 to 99 |
Default Value | 8 |
LabVIEW Versions | |
OS's Supported | |
Notes | None |
showSubVIName
Example | showSubVIName=TRUE
|
---|---|
Description | Show subVI names when dropped |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | FALSE |
LabVIEW Versions | |
OS's Supported | |
Notes | None |
showTipStringsOnTerms
Example | showTipStringsOnTerms=FALSE
|
---|---|
Description | Show tip-strips over terminals |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | TRUE |
LabVIEW Versions | |
OS's Supported | |
Notes | None |
showWireDots
Example | showWireDots=TRUE
|
---|---|
Description | Show dots at wire junctions |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | FALSE |
LabVIEW Versions | |
OS's Supported | |
Notes | None |
showWireGuides
Example | showWireGuides=FALSE
|
---|---|
Description | Show dashed line while wiring |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | TRUE |
LabVIEW Versions | |
OS's Supported | |
Notes | None |
structuresFadeToDiagramBeneath
Example | structuresFadeToDiagramBeneath=FALSE
|
---|---|
Description | Makes the diagram of structures semi-transparent so that you can see objects behind them. |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | TRUE |
LabVIEW Versions | |
OS's Supported | |
Notes | Enabling this setting will slow down the development environment on large Block Diagrams |
transparentBDLabels
Example | transparentBDLabels=TRUE
|
---|---|
Description | Use transparent name labels |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | FALSE |
LabVIEW Versions | |
OS's Supported | |
Notes | None |
UseNumbersForNewVIIcons
Example | UseNumbersForNewVIIcons=FALSE
|
---|---|
Description | Tells LabVIEW whether to automatically include a number (1-9) in the lower-right corner of each new VI's icon. |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | TRUE |
LabVIEW Versions | |
OS's Supported | |
Notes | LabVIEW 8.6 only. This key replaces UseNumbersForNewVIIconsInLibs from LabVIEW 8.5. |
UseNumbersForNewVIIconsInLibs
Example | UseNumbersForNewVIIconsInLibs=FALSE
|
---|---|
Description | Tells LabVIEW whether to automatically include a number (1-9) in the lower-right corner of each new VI's icon for VIs created inside libraries (.lvlib, .lvclass, .xctl, .lvsc, etc). |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | TRUE |
LabVIEW Versions | |
OS's Supported | |
Notes | LabVIEW 8.5 only. This key was replaced by UseNumbersForNewVIIcons in LabVIEW 8.6. |
viCaptionTipStrings
Example | viCaptionTipStrings=FALSE
|
---|---|
Description | Use control captions for subVI tip-strips |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | TRUE |
LabVIEW Versions | |
OS's Supported | |
Notes | None |
viTitleInPalettes
Example | viTitleInPalettes=TRUE
|
---|---|
Description | Use Window Titles in function palettes |
Datatype | Boolean |
Permitted Values | TRUE or FALSE |
Default Value | FALSE |
LabVIEW Versions | |
OS's Supported | |
Notes | None |