Jump to content

LabVIEW configuration file/Block Diagram: Difference between revisions

From LabVIEW Wiki
No edit summary
Added entry for UseNumbersForNewVIIconsInLibs.
Line 247: Line 247:
| OS4 = u
| OS4 = u
| notes = None
| notes = None
}}
{{ labviewconfigurationkey
| keyname = UseNumbersForNewVIIconsInLibs
| example = UseNumbersForNewVIIconsInLibs=FALSE
| datatype = b
| description = Tells LabVIEW whether to automatically generate include a number (1-9) in the lower-right corner of each new VI's icon for VIs created inside libraries (.lvlib, .lvclass, .xctl, .lvsc, etc).
| permitted_values = TRUE or FALSE
| default = TRUE
| LV1 = 8
| LV2 =
| LV3 =
| LV4 =
| LV5 =
| LV6 =
| OS1 =w
| OS2 =m
| OS3 =l
| OS4 =
| notes = LabVIEW 8.5 only
}}
}}
{{ labviewconfigurationkey
{{ labviewconfigurationkey

Revision as of 00:40, 15 October 2007

This is a list of LabVIEW ini File settings relating to Block Diagram behaviour.

autoWireMax

Example autoWireMax=24
Description Maximum distance between nodes for autowiring to be active
Datatype Integer
Permitted Values 1 to 232
Default Value 16
LabVIEW Versions

6.x , 7.x , 8.x

OS's Supported

Notes This setting is only effective if enableAutoWire is set to TRUE

autoWireMin

Example autoWireMin=8
Description Minimum distance between nodes for autowiring to be active
Datatype Integer
Permitted Values 1 to 232
Default Value 4
LabVIEW Versions

6.x , 7.x , 8.x

OS's Supported

Notes This setting is only effective if enableAutoWire is set to TRUE

copyDeleteFPDCOFromFPTerm

Example copyDeleteFPDCOFromFPTerm=TRUE
Description Delete front panel terminals from diagram
Datatype Boolean
Permitted Values TRUE or FALSE
Default Value FALSE
LabVIEW Versions

, 4.x , 5.x , 6.x , 7.x , 8.x

OS's Supported

Notes None

enableAutoWire

Example enableAutoWire=FALSE
Description Enable Auto Wiring
Datatype Boolean
Permitted Values TRUE or FALSE
Default Value TRUE
LabVIEW Versions

6.x , 7.x , 8.x

OS's Supported

Notes None

funkyErrClustWire

Example funkyErrClustWire=FALSE
Description Change Error Cluster wires color from the standard cluster pink to a more distinctive brown/green color
Datatype Boolean
Permitted Values TRUE or FALSE
Default Value LabVIEW 5.1, 6.x, 7.x: FALSE, LabVIEW 8.x: TRUE
LabVIEW Versions

5.x , 6.x , 7.x , 8.x

OS's Supported

Notes None

inlineSubVIEnabled

Example inlineSubVIEnabled=FALSE
Description Allows the context menu item "Inline SubVI" on any SubVI which inserts the code directly into the block diagram containing the SubVI.
Datatype Boolean
Permitted Values TRUE or FALSE
Default Value FALSE
LabVIEW Versions

6.x , 7.x , 8.x

OS's Supported

Notes None

maxUndoSteps

Example maxUndoSteps=50
Description Maximum undo steps per VI
Datatype Integer
Permitted Values 1 to 99
Default Value 8
LabVIEW Versions

5.x , 6.x , 7.x , 8.x

OS's Supported

Notes None

showSubVIName

Example showSubVIName=TRUE
Description Show subVI names when dropped
Datatype Boolean
Permitted Values TRUE or FALSE
Default Value FALSE
LabVIEW Versions

4.x , 5.x , 6.x , 7.x , 8.x

OS's Supported

Notes None

showTipStringsOnTerms

Example showTipStringsOnTerms=FALSE
Description Show tip-strips over terminals
Datatype Boolean
Permitted Values TRUE or FALSE
Default Value TRUE
LabVIEW Versions

4.x , 5.x , 6.x , 7.x , 8.x

OS's Supported

Notes None

showWireDots

Example showWireDots=TRUE
Description Show dots at wire junctions
Datatype Boolean
Permitted Values TRUE or FALSE
Default Value FALSE
LabVIEW Versions

7.x , 8.x

OS's Supported

Notes None

showWireGuides

Example showWireGuides=FALSE
Description Show dashed line while wiring
Datatype Boolean
Permitted Values TRUE or FALSE
Default Value TRUE
LabVIEW Versions

4.x , 5.x , 6.x , 7.x , 8.x

OS's Supported

Notes None

structuresFadeToDiagramBeneath

Example structuresFadeToDiagramBeneath=FALSE
Description Makes the diagram of structures semi-transparent so that you can see objects behind them.
Datatype Boolean
Permitted Values TRUE or FALSE
Default Value TRUE
LabVIEW Versions

6.x , 7.x , 8.x

OS's Supported

Notes Enabling this setting will slow down the development environment on large Block Diagrams

transparentBDLabels

Example transparentBDLabels=TRUE
Description Use transparent name labels
Datatype Boolean
Permitted Values TRUE or FALSE
Default Value FALSE
LabVIEW Versions

5.x , 6.x , 7.x , 8.x

OS's Supported

Notes None

UseNumbersForNewVIIconsInLibs

Example UseNumbersForNewVIIconsInLibs=FALSE
Description Tells LabVIEW whether to automatically generate include a number (1-9) in the lower-right corner of each new VI's icon for VIs created inside libraries (.lvlib, .lvclass, .xctl, .lvsc, etc).
Datatype Boolean
Permitted Values TRUE or FALSE
Default Value TRUE
LabVIEW Versions

8.x

OS's Supported

Notes LabVIEW 8.5 only

viCaptionTipStrings

Example viCaptionTipStrings=FALSE
Description Use control captions for subVI tip-strips
Datatype Boolean
Permitted Values TRUE or FALSE
Default Value TRUE
LabVIEW Versions

5.x , 6.x , 7.x , 8.x

OS's Supported

Notes None

viTitleInPalettes

Example viTitleInPalettes=TRUE
Description Use Window Titles in function palettes
Datatype Boolean
Permitted Values TRUE or FALSE
Default Value FALSE
LabVIEW Versions

5.x , 6.x , 7.x , 8.x

OS's Supported

Notes None