Jump to content

LabVIEW configuration file/Execution System: Difference between revisions

From LabVIEW Wiki
No edit summary
Line 5: Line 5:
Example: <code>ESys.StdNParallel=5</code><br/>
Example: <code>ESys.StdNParallel=5</code><br/>
Description: Defines the number of threads to start in each execution system and priority level.<br/>
Description: Defines the number of threads to start in each execution system and priority level.<br/>
Datatype: <FONT COLOR=#0000FF>Integer</FONT><br/>
Datatype: Integer<br/>
Permitted Values: -1 to 8 (see notes)<br/>
Permitted Values: -1 to 8 (see notes)<br/>
Default Value: <code>1</code><br/>
Default Value: <code>1</code><br/>
LabVIEW Versions: 5.1, 6.1, 7.1, 8.x<br/>
LabVIEW Versions: 5.x, 6.x, 7.x, 8.x<br/>
OS's Supported: [[Image:logo.Windows.png]][[Image:logo.Mac.png]][[Image:logo.Linux.png]][[Image:logo.Sun.png]]<br/>
OS's Supported: [[Image:logo.Windows.png]][[Image:logo.Mac.png]][[Image:logo.Linux.png]][[Image:logo.Sun.png]]<br/>
Notes:
Notes:

Revision as of 23:24, 8 May 2007

Template:LabVIEW configuration back This is a list of LabVIEW ini File settings relating to the Execution System.

ESys.StdNParallel

Example: ESys.StdNParallel=5
Description: Defines the number of threads to start in each execution system and priority level.
Datatype: Integer
Permitted Values: -1 to 8 (see notes)
Default Value: 1
LabVIEW Versions: 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes:

  • 0 is equivalent to turning off the Preferences menu item "Run with multiple threads"
  • 1 is the default value, equivalent to turning on "Run with multiple threads"
  • 2 to 8 defines a higher number of threads to start (i.e. a 5x5 matrix)
  • -1 tells LabVIEW to start with a custom set of threading parameters as defined by ESys.xxx.yyyy keys

ESys.xxx.yyyy

Example: Various ...