Jump to content

LabVIEW configuration file/Execution System: Difference between revisions

From LabVIEW Wiki
No edit summary
No edit summary
Line 25: Line 25:
* -1 tells LabVIEW to start with a custom set of threading parameters as defined by [[#ESys.xxx.yyyy|ESys.xxx.yyyy]] keys
* -1 tells LabVIEW to start with a custom set of threading parameters as defined by [[#ESys.xxx.yyyy|ESys.xxx.yyyy]] keys
}}
}}
{{ labviewconfigurationkey
| keyname = runAsService
| example =runAsService=True
| datatype =b
| description =This key tells the LabVIEW Run-Time Engine to ignore the Windows WM_ENDSESSION message that is sent when a user logs off! Use this key when your LabVIEW application is configured to run as a Windows service and has a user interface (service allowed to interact with desktop). The key prevents your LabVIEW application to quit when a user logs off.
| permitted_values =True or False
| default =False
| LV1 = 5
| LV2 = 6
| LV3 = 7
| LV4 = 8
| LV5 =
| LV6 =
| OS1 =w
| OS2 =
| OS3 =
| OS4 =
| notes =<br>
}}
== ESys.xxx.yyyy ==
== ESys.xxx.yyyy ==
Example: Various
Example: Various

Revision as of 07:59, 10 September 2007

Template:LabVIEW configuration back This is a list of LabVIEW ini File settings relating to the Execution System.

ESys.StdNParallel

Example ESys.StdNParallel=5
Description Defines the number of threads to start in each execution system and priority level.
Datatype Integer
Permitted Values -1 to 8 (see notes)
Default Value 1
LabVIEW Versions

5.x , 6.x , 7.x , 8.x

OS's Supported

Notes
  • 0 is equivalent to turning off the Preferences menu item "Run with multiple threads"
  • 1 is the default value, equivalent to turning on "Run with multiple threads"
  • 2 to 8 defines a higher number of threads to start (i.e. a 5x5 matrix)
  • -1 tells LabVIEW to start with a custom set of threading parameters as defined by ESys.xxx.yyyy keys

runAsService

Example runAsService=True
Description This key tells the LabVIEW Run-Time Engine to ignore the Windows WM_ENDSESSION message that is sent when a user logs off! Use this key when your LabVIEW application is configured to run as a Windows service and has a user interface (service allowed to interact with desktop). The key prevents your LabVIEW application to quit when a user logs off.
Datatype Boolean
Permitted Values True or False
Default Value False
LabVIEW Versions

5.x , 6.x , 7.x , 8.x

OS's Supported

Notes


ESys.xxx.yyyy

Example: Various ...