Jump to content

LabVIEW configuration file/Block Diagram: Difference between revisions

From LabVIEW Wiki
Line 1: Line 1:
{{LabVIEW configuration back}}
{{LabVIEW configuration back}}
This is a list of LabVIEW ini File settings relating to Block Diagram behaviour.
This is a list of LabVIEW ini File settings relating to Block Diagram behaviour.
{{ labviewconfigurationkey
| keyname =  autoWireMax
| example = autoWireMax=24
| datatype = i
| description = Maximum distance between nodes for autowiring to be active
| permitted_values = 1 to 2<sup>32</sup>
| default = 16
| LV1 = 6
| LV2 = 7
| LV3 = 8
| LV4 =
| LV5 =
| LV6 =
| OS1 = w
| OS2 = m
| OS3 = l
| OS4 = u
| notes = This setting is only effective if [[#enableAutoWire|enableAutoWire]] is set to TRUE
}}


== autoWireMax ==
== autoWireMax ==

Revision as of 22:26, 10 May 2007

Template:LabVIEW configuration back This is a list of LabVIEW ini File settings relating to Block Diagram behaviour.

autoWireMax

Example autoWireMax=24
Description Maximum distance between nodes for autowiring to be active
Datatype Integer
Permitted Values 1 to 232
Default Value 16
LabVIEW Versions

6.x , 7.x , 8.x

OS's Supported

Notes This setting is only effective if enableAutoWire is set to TRUE

autoWireMax

Example: autoWireMax=24
Description: Maximum distance between nodes for autowiring to be active
Datatype: Integer
Permitted Values: 1 to 232
Default Value: 16
LabVIEW Versions: 6.x, 7.x, 8.x
OS's Supported:
Notes: This setting is only effective if enableAutoWire is set to TRUE

autoWireMin

Example: autoWireMin=8
Description: Minimum distance between nodes for autowiring to be active
Datatype: Integer
Permitted Values: 1 to 232
Default Value: 4
LabVIEW Versions: 6.x, 7.x, 8.x
OS's Supported:
Notes: This setting is only effective if enableAutoWire is set to TRUE

copyDeleteFPDCOFromFPTerm

Example: copyDeleteFPDCOFromFPTerm=TRUE
Description: Delete front panel terminals from diagram
Datatype: Boolean
Permitted Values: TRUE or FALSE
Default Value: FALSE
LabVIEW Versions: 4.x, 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes: None

enableAutoWire

Example: enableAutoWire=FALSE
Description: Enable Auto Wiring
Datatype: Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions: 6.x, 7.x, 8.x
OS's Supported:
Notes: None

funkyErrClustWire

Example: funkyErrClustWire=FALSE
Description: Change Error Cluster wires color from the standard cluster pink to a more appealing brown/green color
Datatype: Boolean
Permitted Values: TRUE or FALSE
Default Value: LabVIEW 5.1, 6.x, 7.x: FALSE, LabVIEW 8.x: TRUE
LabVIEW Versions: 5.1, 6.x, 7.x, 8.x
OS's Supported:
Notes: None

inlineSubVIEnabled

Example: inlineSubVIEnabled=FALSE
Description: Allows the context menu item "Inline SubVI" on any SubVI which inserts the code directly into the block diagram containing the SubVI.
Datatype: Boolean
Permitted Values: TRUE or FALSE
Default Value: FALSE
LabVIEW Versions: 6.x, 7.x, 8.x
OS's Supported:
Notes: None

maxUndoSteps

Example: maxUndoSteps=50
Description: Maximum undo steps per VI
Datatype: Integer
Permitted Values: 1 to 232
Default Value: 8
LabVIEW Versions: 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes: None

showSubVIName

Example: showSubVIName=TRUE
Description: Show subVI names when dropped
Datatype: Boolean
Permitted Values: TRUE or FALSE
Default Value: FALSE
LabVIEW Versions: 4.x, 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes: None

showTipStringsOnTerms

Example: showTipStringsOnTerms=FALSE
Description: Show tip-strips over terminals
Datatype: Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions: 4.x, 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes: None

showWireDots

Example: showWireDots=TRUE
Description: Show dots at wire junctions
Datatype: Boolean
Permitted Values: TRUE or FALSE
Default Value: FALSE
LabVIEW Versions: 7.x, 8.x
OS's Supported:
Notes: None

showWireGuides

Example: showWireGuides=FALSE
Description: None
Datatype: Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions: 4.x, 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes: None

structuresFadeToDiagramBeneath

Example: structuresFadeToDiagramBeneath=FALSE
Description: Makes the diagram of structures semi-transparent so that you can see objects behind them.
Datatype: Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions: 6.x, 7.x, 8.x
OS's Supported:
Notes: Enabling this setting will slow down the development environment on large Block Diagrams

transparentBDLabels

Example: transparentBDLabels=TRUE
Description: Use transparent name labels
Datatype: Boolean
Permitted Values: TRUE or FALSE
Default Value: FALSE
LabVIEW Versions: 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes: None

viCaptionTipStrings

Example: viCaptionTipStrings=FALSE
Description: Use control captions for subVI tip-strips
Datatype: Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions: 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes: None

viTitleInPalettes

Example: viTitleInPalettes=TRUE
Description: Use Window Titles in function palettes
Datatype: Boolean
Permitted Values: TRUE or FALSE
Default Value: FALSE
LabVIEW Versions: 5.x, 6.x, 7.x, 8.x
OS's Supported:
Notes: None