LabVIEW configuration file/Block Diagram: Difference between revisions
Appearance
m minor updates to resizeObjectsOnBlockDiagram entry. LV version update, note update. |
Added LogUnwiredErrors to Block Diagram configuration tokens |
||
| (One intermediate revision by one other user not shown) | |||
| Line 156: | Line 156: | ||
| OS4 = u | | OS4 = u | ||
| notes = None | | notes = None | ||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = LogUnwiredErrors | |||
| example = LogUnwiredErrors=True | |||
| datatype = b | |||
| description = When enabled, unwired errors are logged to a log file. | |||
| permitted_values = TRUE or FALSE | |||
| default = FALSE | |||
| LV1 = 25.3 | |||
| LV2 = | |||
| LV3 = | |||
| LV4 = | |||
| LV5 = | |||
| LV6 = | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = | |||
| notes = Also supported for built applications. | |||
}} | }} | ||
{{ labviewconfigurationkey | {{ labviewconfigurationkey | ||
| Line 295: | Line 314: | ||
| notes = None | | notes = None | ||
}} | }} | ||
{{ labviewconfigurationkey | {{labviewconfigurationkey | ||
| keyname = structuresFadeToDiagramBeneath | | keyname = structuresFadeToDiagramBeneath | ||
| example = structuresFadeToDiagramBeneath=FALSE | | example = structuresFadeToDiagramBeneath=FALSE | ||
| Line 312: | Line 331: | ||
| OS3 = l | | OS3 = l | ||
| OS4 = u | | OS4 = u | ||
| notes = Enabling this setting will slow down the development environment on large Block Diagrams | | notes = Enabling this setting will slow down the development environment on large Block Diagrams. | ||
}} | }} | ||
{{ labviewconfigurationkey | {{ labviewconfigurationkey | ||
Latest revision as of 16:04, 22 July 2025
This is a list of LabVIEW ini File settings relating to Block Diagram behaviour.
allowDragDropFromFileDlg
| Example | allowDragDropFromFileDlg=TRUE
|
|---|---|
| Description | Enables drag and drop functionality from the file dialog to the block diagram of a vi |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | This functionality existed in LV 5.0 -> LV 7.1, was removed in LV 8.x, and added back in as an ini setting in 8.5 |
allowOpenFPOfInstanceVIs
| Example | allowOpenFPOfInstanceVIs=TRUE
|
|---|---|
| Description | Changes the behavior of the Convert Instance VI to Standard VI menu option when right-clicking a malleable VI on the block diagram to instead open the instance VI |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes |
autoWireMax
| Example | autoWireMax=24
|
|---|---|
| Description | Maximum distance between nodes for autowiring to be active |
| Datatype | Integer |
| Permitted Values | 1 to 232 |
| Default Value | 16 |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | This setting is only effective if enableAutoWire is set to TRUE |
autoWireMin
| Example | autoWireMin=8
|
|---|---|
| Description | Minimum distance between nodes for autowiring to be active |
| Datatype | Integer |
| Permitted Values | 1 to 232 |
| Default Value | 4 |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | This setting is only effective if enableAutoWire is set to TRUE |
copyDeleteFPDCOFromFPTerm
| Example | copyDeleteFPDCOFromFPTerm=TRUE
|
|---|---|
| Description | Delete front panel terminals from diagram |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
enableAutoWire
| Example | enableAutoWire=FALSE
|
|---|---|
| Description | Enables automatic wire routing. This key is set by the Options dialog for Enable automatic wire routing in section Wiring under category Block Diagram. |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes |
FancyFPTerms
| Example | FancyFPTerms=FALSE
|
|---|---|
| Description | Enables placing front panel terminals as icons. This key is set by the Options dialog for Place front panel terminals as icons in section General under category Block Diagram. |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | (Depends on LV Version) |
| LabVIEW Versions | |
| OS's Supported | |
| Notes |
funkyErrClustWire
| Example | funkyErrClustWire=FALSE
|
|---|---|
| Description | Change Error Cluster wires color from the standard cluster pink to a more distinctive brown/green color |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | LabVIEW 5.1, 6.x, 7.x: FALSE, LabVIEW 8.x: TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
inlineSubVIEnabled
| Example | inlineSubVIEnabled=FALSE
|
|---|---|
| Description | Allows the context menu item "Inline SubVI" on any SubVI which inserts the code directly into the block diagram containing the SubVI. |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
LogUnwiredErrors
| Example | LogUnwiredErrors=True
|
|---|---|
| Description | When enabled, unwired errors are logged to a log file. |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | Also supported for built applications. |
maxUndoSteps
| Example | maxUndoSteps=50
|
|---|---|
| Description | Maximum undo steps per VI |
| Datatype | Integer |
| Permitted Values | 1 to 99 |
| Default Value | 8 |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
resizeObjectsOnBlockDiagram
| Example | resizeObjectsOnBlockDiagram=TRUE
|
|---|---|
| Description | Enables "Resize Objects" functionality on the block diagram of a vi. |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | Mainly useful for resizing objects on the structures palette, comment boxes, and labels. |
showBDConstName
| Example | showBDConstName=TRUE
|
|---|---|
| Description | Show Constant Label with name of terminal when creating from a terminal |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
ShowRedXOnWire
| Example | ShowRedXOnWire=TRUE
|
|---|---|
| Description | Shows a red "X" (and directional arrows) on top of a broken wire. |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes |
showSubVIName
| Example | showSubVIName=TRUE
|
|---|---|
| Description | Show subVI names when dropped |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
showTipStringsOnTerms
| Example | showTipStringsOnTerms=FALSE
|
|---|---|
| Description | Show tip-strips over terminals |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
showWireDots
| Example | showWireDots=TRUE
|
|---|---|
| Description | Show dots at wire junctions |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
showWireGuides
| Example | showWireGuides=FALSE
|
|---|---|
| Description | Show dashed line while wiring |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
structuresFadeToDiagramBeneath
| Example | structuresFadeToDiagramBeneath=FALSE
|
|---|---|
| Description | Makes the diagram of structures semi-transparent so that you can see objects behind them. |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | Enabling this setting will slow down the development environment on large Block Diagrams. |
transparentBDLabels
| Example | transparentBDLabels=TRUE
|
|---|---|
| Description | Use transparent name labels |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
UseNumbersForNewVIIcons
| Example | UseNumbersForNewVIIcons=FALSE
|
|---|---|
| Description | Tells LabVIEW whether to automatically include a number (1-9) in the lower-right corner of each new VI's icon. |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | This key replaces UseNumbersForNewVIIconsInLibs from LabVIEW 8.5. |
UseNumbersForNewVIIconsInLibs
| Example | UseNumbersForNewVIIconsInLibs=FALSE
|
|---|---|
| Description | Tells LabVIEW whether to automatically include a number (1-9) in the lower-right corner of each new VI's icon for VIs created inside libraries (.lvlib, .lvclass, .xctl, .lvsc, etc). |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | This key was replaced by UseNumbersForNewVIIcons in LabVIEW 8.6. |
viCaptionTipStrings
| Example | viCaptionTipStrings=FALSE
|
|---|---|
| Description | Use control captions for subVI tip-strips |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
SourceOnlyEnvironment
| Example | SourceOnlyEnvironment=True
|
|---|---|
| Description | The option "Separate Compiled Code from Source" is turned on by default |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | Currently this causes "uncomfortably" slow load times when opening a large number of VIs which this option enabled. Reference, NI forums |