== | {{ labviewconfigurationkey | ||
| keyname = allowDragDropFromFileDlg | |||
| example = allowDragDropFromFileDlg=TRUE | |||
| datatype = b | |||
| description = Enables drag and drop functionality from the file dialog to the block diagram of a vi | |||
| permitted_values = TRUE or FALSE | |||
| default = FALSE | |||
| LV1 = 8.5 | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
| notes = This functionality existed in LV 5.0 -> LV 7.1, was removed in LV 8.x, and added back in as an ini setting in 8.5 | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = allowOpenFPOfInstanceVIs | |||
| example = allowOpenFPOfInstanceVIs=TRUE | |||
| datatype = b | |||
| description = Changes the behavior of the Convert Instance VI to Standard VI menu option when right-clicking a malleable VI on the block diagram to instead open the instance VI | |||
| permitted_values = TRUE or FALSE | |||
| default = FALSE | |||
| LV1 = 2019 onwards | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| notes = | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = autoWireMax | |||
| example = autoWireMax=24 | |||
| datatype = i | |||
| description = Maximum distance between nodes for autowiring to be active | |||
| permitted_values = 1 to 2<sup>32</sup> | |||
| default = 16 | |||
| LV1 =6 | |||
| LV2 =7 | |||
| LV3 =8 | |||
| LV4 = | |||
| LV5 = | |||
| LV6 = | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
| notes = This setting is only effective if [[#enableAutoWire|enableAutoWire]] is set to TRUE | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = autoWireMin | |||
| example = autoWireMin=8 | |||
| datatype = i | |||
| description = Minimum distance between nodes for autowiring to be active | |||
| permitted_values = 1 to 2<sup>32</sup> | |||
| default = 4 | |||
| LV1 = 6 | |||
| LV2 = 7 | |||
| LV3 = 8 | |||
| LV4 = | |||
| LV5 = | |||
| LV6 = | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
| notes = This setting is only effective if [[#enableAutoWire|enableAutoWire]] is set to TRUE | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = copyDeleteFPDCOFromFPTerm | |||
| example = copyDeleteFPDCOFromFPTerm=TRUE | |||
| datatype = b | |||
| description = Delete front panel terminals from diagram | |||
| permitted_values = TRUE or FALSE | |||
| default = FALSE | |||
| LV1 = | |||
| LV2 = 4 | |||
| LV3 = 5 | |||
| LV4 = 6 | |||
| LV5 = 7 | |||
| LV6 = 8 | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
| notes = None | |||
}} | |||
== | {{ labviewconfigurationkey | ||
| keyname = enableAutoWire | |||
| example = enableAutoWire=FALSE | |||
| datatype = b | |||
| description = Enables automatic wire routing. This key is set by the [[Options dialog]] for ''Enable automatic wire routing'' in section [[Block Diagram options#Wiring|Wiring]] under category [[Block Diagram options|Block Diagram]]. | |||
| permitted_values = TRUE or FALSE | |||
| default = TRUE | |||
| LV1 = 6 | |||
| LV2 = 7 | |||
| LV3 = 8 | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
}} | |||
== | {{ labviewconfigurationkey | ||
| keyname = FancyFPTerms | |||
| example = FancyFPTerms=FALSE | |||
| datatype = b | |||
| description = Enables placing front panel terminals as icons. This key is set by the [[Options dialog]] for ''Place front panel terminals as icons'' in section [[Block Diagram options#General|General]] under category [[Block Diagram options|Block Diagram]]. | |||
| permitted_values = TRUE or FALSE | |||
| default = (Depends on LV Version) | |||
| LV1 = 7 | |||
| LV2 = 8 | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
}} | |||
== funkyErrClustWire == | {{ labviewconfigurationkey | ||
| keyname = funkyErrClustWire | |||
| example = funkyErrClustWire=FALSE | |||
| datatype = b | |||
| description = Change Error Cluster wires color from the standard cluster pink to a more distinctive brown/green color | |||
| permitted_values = TRUE or FALSE | |||
| default = LabVIEW 5.1, 6.x, 7.x: FALSE, LabVIEW 8.x: TRUE | |||
| LV1 = 5 | |||
| LV2 = 6 | |||
| LV3 = 7 | |||
| LV4 = 8 | |||
| LV5 = | |||
| LV6 = | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
| notes = None | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = inlineSubVIEnabled | |||
| example = inlineSubVIEnabled=FALSE | |||
| datatype = b | |||
| description = Allows the context menu item "Inline SubVI" on any SubVI which inserts the code directly into the block diagram containing the SubVI. | |||
| permitted_values = TRUE or FALSE | |||
| default = FALSE | |||
| LV1 = 6 | |||
| LV2 = 7 | |||
| LV3 = 8 | |||
| LV4 = | |||
| LV5 = | |||
| LV6 = | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
| notes = None | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = LogUnwiredErrors | |||
| example = LogUnwiredErrors=True | |||
| datatype = b | |||
| description = When enabled, unwired errors are logged to a log file. | |||
| permitted_values = TRUE or FALSE | |||
| default = FALSE | |||
| LV1 = 25.3 | |||
| LV2 = | |||
| LV3 = | |||
| LV4 = | |||
| LV5 = | |||
| LV6 = | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = | |||
| notes = Also supported for built applications. | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = maxUndoSteps | |||
| example = maxUndoSteps=50 | |||
| datatype = i | |||
| description = Maximum undo steps per VI | |||
| permitted_values = 1 to 99 | |||
| default = 8 | |||
| LV1 = 5 | |||
| LV2 = 6 | |||
| LV3 = 7 | |||
| LV4 = 8 | |||
| LV5 = | |||
| LV6 = | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
| notes = None | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = resizeObjectsOnBlockDiagram | |||
| example = resizeObjectsOnBlockDiagram=TRUE | |||
| datatype = b | |||
| description = Enables "Resize Objects" functionality on the block diagram of a vi. | |||
| permitted_values = TRUE or FALSE | |||
| default = FALSE | |||
| LV1 = 2015 onward | |||
| OS1 = w | |||
| notes = Mainly useful for resizing objects on the structures palette, comment boxes, and labels. | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = showBDConstName | |||
| example = showBDConstName=TRUE | |||
| datatype = b | |||
| description = Show Constant Label with name of terminal when creating from a terminal | |||
| permitted_values = TRUE or FALSE | |||
| default = FALSE | |||
| LV1 =4 | |||
| LV2 =5 | |||
| LV3 =6 | |||
| LV4 =7 | |||
| LV5 =8 | |||
| LV6 = | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
| notes = None | |||
}} | |||
== | {{ labviewconfigurationkey | ||
| keyname = ShowRedXOnWire | |||
| example = ShowRedXOnWire=TRUE | |||
| datatype = b | |||
| description = Shows a red "X" (and directional arrows) on top of a broken wire. | |||
| permitted_values = TRUE or FALSE | |||
| default = TRUE | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
}} | |||
== | {{ labviewconfigurationkey | ||
| keyname = showSubVIName | |||
| example = showSubVIName=TRUE | |||
| datatype = b | |||
| description = Show subVI names when dropped | |||
| permitted_values = TRUE or FALSE | |||
LabVIEW | | default = FALSE | ||
| LV1 =4 | |||
| LV2 =5 | |||
| LV3 =6 | |||
| LV4 =7 | |||
| LV5 =8 | |||
| LV6 = | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
| notes = None | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = showTipStringsOnTerms | |||
| example = showTipStringsOnTerms=FALSE | |||
| datatype = b | |||
| description = Show tip-strips over terminals | |||
| permitted_values = TRUE or FALSE | |||
| default = TRUE | |||
| LV1 =4 | |||
| LV2 =5 | |||
| LV3 =6 | |||
| LV4 =7 | |||
| LV5 =8 | |||
| LV6 = | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
| notes = None | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = showWireDots | |||
| example = showWireDots=TRUE | |||
| datatype = b | |||
| description = Show dots at wire junctions | |||
| permitted_values = TRUE or FALSE | |||
| default = FALSE | |||
| LV1 =7 | |||
| LV2 =8 | |||
| LV3 = | |||
| LV4 = | |||
| LV5 = | |||
| LV6 = | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
| notes = None | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = showWireGuides | |||
| example = showWireGuides=FALSE | |||
| datatype = b | |||
| description = Show dashed line while wiring | |||
| permitted_values = TRUE or FALSE | |||
| default = TRUE | |||
| LV1 =4 | |||
| LV2 =5 | |||
| LV3 =6 | |||
| LV4 =7 | |||
| LV5 =8 | |||
| LV6 = | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
| notes = None | |||
}} | |||
{{labviewconfigurationkey | |||
| keyname = structuresFadeToDiagramBeneath | |||
| example = structuresFadeToDiagramBeneath=FALSE | |||
| datatype = b | |||
| description = Makes the diagram of structures semi-transparent so that you can see objects behind them. | |||
| permitted_values = TRUE or FALSE | |||
| default = TRUE | |||
| LV1 =6 | |||
| LV2 =7 | |||
| LV3 =8 | |||
| LV4 = | |||
| LV5 = | |||
| LV6 = | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
| notes = Enabling this setting will slow down the development environment on large Block Diagrams. | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = transparentBDLabels | |||
| example = transparentBDLabels=TRUE | |||
| datatype = b | |||
| description = Use transparent name labels | |||
| permitted_values = TRUE or FALSE | |||
| default = FALSE | |||
| LV1 =5 | |||
| LV2 =6 | |||
| LV3 =7 | |||
| LV4 =8 | |||
| LV5 = | |||
| LV6 = | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
| notes = None | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = UseNumbersForNewVIIcons | |||
| example = UseNumbersForNewVIIcons=FALSE | |||
| datatype = b | |||
| description = Tells LabVIEW whether to automatically include a number (1-9) in the lower-right corner of each new VI's icon. | |||
| permitted_values = TRUE or FALSE | |||
| default = TRUE | |||
| LV1 = 8.6 | |||
| LV2 = | |||
| LV3 = | |||
| LV4 = | |||
| LV5 = | |||
| LV6 = | |||
| OS1 =w | |||
| OS2 =m | |||
| OS3 =l | |||
| OS4 = | |||
| notes = This key replaces [[#UseNumbersForNewVIIconsInLibs|UseNumbersForNewVIIconsInLibs]] from LabVIEW 8.5. | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = UseNumbersForNewVIIconsInLibs | |||
| example = UseNumbersForNewVIIconsInLibs=FALSE | |||
| datatype = b | |||
| description = Tells LabVIEW whether to automatically include a number (1-9) in the lower-right corner of each new VI's icon for VIs created inside libraries (.lvlib, .lvclass, .xctl, .lvsc, etc). | |||
| permitted_values = TRUE or FALSE | |||
| default = TRUE | |||
| LV1 = 8.5 | |||
| LV2 = | |||
| LV3 = | |||
| LV4 = | |||
| LV5 = | |||
| LV6 = | |||
| OS1 =w | |||
| OS2 =m | |||
| OS3 =l | |||
| OS4 = | |||
| notes = This key was replaced by [[#UseNumbersForNewVIIcons|UseNumbersForNewVIIcons]] in LabVIEW 8.6. | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = viCaptionTipStrings | |||
| example = viCaptionTipStrings=FALSE | |||
| datatype = b | |||
| description = Use control captions for subVI tip-strips | |||
| permitted_values = TRUE or FALSE | |||
| default = TRUE | |||
| LV1 =5 | |||
| LV2 =6 | |||
| LV3 =7 | |||
| LV4 =8 | |||
| LV5 = | |||
| LV6 = | |||
| OS1 = w | |||
| OS2 = m | |||
| OS3 = l | |||
| OS4 = u | |||
| notes = None | |||
}} | |||
{{ labviewconfigurationkey | |||
| keyname = SourceOnlyEnvironment | |||
| example = SourceOnlyEnvironment=True | |||
| datatype = b | |||
| description = The option "Separate Compiled Code from Source" is turned on by default | |||
| permitted_values = TRUE or FALSE | |||
| default = FALSE | |||
| LV1 =10 | |||
| LV2 = | |||
| LV3 = | |||
| LV4 = | |||
| LV5 = | |||
| LV6 = | |||
| OS1 = w | |||
| OS2 = | |||
| OS3 = | |||
| OS4 = | |||
| notes = Currently this causes "uncomfortably" slow load times when opening a large number of VIs which this option enabled. Reference, [https://decibel.ni.com/content/groups/large-labview-application-development/blog/2010/09 NI forums] | |||
}} | |||
[[Category:Configuration File|Block Diagram]] | |||
Latest revision as of 16:04, 22 July 2025
This is a list of LabVIEW ini File settings relating to Block Diagram behaviour.
allowDragDropFromFileDlg
| Example | allowDragDropFromFileDlg=TRUE
|
|---|---|
| Description | Enables drag and drop functionality from the file dialog to the block diagram of a vi |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | This functionality existed in LV 5.0 -> LV 7.1, was removed in LV 8.x, and added back in as an ini setting in 8.5 |
allowOpenFPOfInstanceVIs
| Example | allowOpenFPOfInstanceVIs=TRUE
|
|---|---|
| Description | Changes the behavior of the Convert Instance VI to Standard VI menu option when right-clicking a malleable VI on the block diagram to instead open the instance VI |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes |
autoWireMax
| Example | autoWireMax=24
|
|---|---|
| Description | Maximum distance between nodes for autowiring to be active |
| Datatype | Integer |
| Permitted Values | 1 to 232 |
| Default Value | 16 |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | This setting is only effective if enableAutoWire is set to TRUE |
autoWireMin
| Example | autoWireMin=8
|
|---|---|
| Description | Minimum distance between nodes for autowiring to be active |
| Datatype | Integer |
| Permitted Values | 1 to 232 |
| Default Value | 4 |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | This setting is only effective if enableAutoWire is set to TRUE |
copyDeleteFPDCOFromFPTerm
| Example | copyDeleteFPDCOFromFPTerm=TRUE
|
|---|---|
| Description | Delete front panel terminals from diagram |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
enableAutoWire
| Example | enableAutoWire=FALSE
|
|---|---|
| Description | Enables automatic wire routing. This key is set by the Options dialog for Enable automatic wire routing in section Wiring under category Block Diagram. |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes |
FancyFPTerms
| Example | FancyFPTerms=FALSE
|
|---|---|
| Description | Enables placing front panel terminals as icons. This key is set by the Options dialog for Place front panel terminals as icons in section General under category Block Diagram. |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | (Depends on LV Version) |
| LabVIEW Versions | |
| OS's Supported | |
| Notes |
funkyErrClustWire
| Example | funkyErrClustWire=FALSE
|
|---|---|
| Description | Change Error Cluster wires color from the standard cluster pink to a more distinctive brown/green color |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | LabVIEW 5.1, 6.x, 7.x: FALSE, LabVIEW 8.x: TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
inlineSubVIEnabled
| Example | inlineSubVIEnabled=FALSE
|
|---|---|
| Description | Allows the context menu item "Inline SubVI" on any SubVI which inserts the code directly into the block diagram containing the SubVI. |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
LogUnwiredErrors
| Example | LogUnwiredErrors=True
|
|---|---|
| Description | When enabled, unwired errors are logged to a log file. |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | Also supported for built applications. |
maxUndoSteps
| Example | maxUndoSteps=50
|
|---|---|
| Description | Maximum undo steps per VI |
| Datatype | Integer |
| Permitted Values | 1 to 99 |
| Default Value | 8 |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
resizeObjectsOnBlockDiagram
| Example | resizeObjectsOnBlockDiagram=TRUE
|
|---|---|
| Description | Enables "Resize Objects" functionality on the block diagram of a vi. |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | Mainly useful for resizing objects on the structures palette, comment boxes, and labels. |
showBDConstName
| Example | showBDConstName=TRUE
|
|---|---|
| Description | Show Constant Label with name of terminal when creating from a terminal |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
ShowRedXOnWire
| Example | ShowRedXOnWire=TRUE
|
|---|---|
| Description | Shows a red "X" (and directional arrows) on top of a broken wire. |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes |
showSubVIName
| Example | showSubVIName=TRUE
|
|---|---|
| Description | Show subVI names when dropped |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
showTipStringsOnTerms
| Example | showTipStringsOnTerms=FALSE
|
|---|---|
| Description | Show tip-strips over terminals |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
showWireDots
| Example | showWireDots=TRUE
|
|---|---|
| Description | Show dots at wire junctions |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
showWireGuides
| Example | showWireGuides=FALSE
|
|---|---|
| Description | Show dashed line while wiring |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
structuresFadeToDiagramBeneath
| Example | structuresFadeToDiagramBeneath=FALSE
|
|---|---|
| Description | Makes the diagram of structures semi-transparent so that you can see objects behind them. |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | Enabling this setting will slow down the development environment on large Block Diagrams. |
transparentBDLabels
| Example | transparentBDLabels=TRUE
|
|---|---|
| Description | Use transparent name labels |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
UseNumbersForNewVIIcons
| Example | UseNumbersForNewVIIcons=FALSE
|
|---|---|
| Description | Tells LabVIEW whether to automatically include a number (1-9) in the lower-right corner of each new VI's icon. |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | This key replaces UseNumbersForNewVIIconsInLibs from LabVIEW 8.5. |
UseNumbersForNewVIIconsInLibs
| Example | UseNumbersForNewVIIconsInLibs=FALSE
|
|---|---|
| Description | Tells LabVIEW whether to automatically include a number (1-9) in the lower-right corner of each new VI's icon for VIs created inside libraries (.lvlib, .lvclass, .xctl, .lvsc, etc). |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | This key was replaced by UseNumbersForNewVIIcons in LabVIEW 8.6. |
viCaptionTipStrings
| Example | viCaptionTipStrings=FALSE
|
|---|---|
| Description | Use control captions for subVI tip-strips |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | TRUE |
| LabVIEW Versions | |
| OS's Supported | |
| Notes | None |
SourceOnlyEnvironment
| Example | SourceOnlyEnvironment=True
|
|---|---|
| Description | The option "Separate Compiled Code from Source" is turned on by default |
| Datatype | Boolean |
| Permitted Values | TRUE or FALSE |
| Default Value | FALSE |
| LabVIEW Versions | |
| OS's Supported | |