LabVIEW configuration file/VI Server
From LabVIEW Wiki
This is a list of LabVIEW ini File settings relating to VI Server behaviour.
|
server.app.propertiesEnabled
Example: server.app.propertiesEnabled=FALSE
Description: Allow Application Methods and Properties
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions:
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
server.ole.enabled
Example: server.ole.enabled=FALSE
Description: Enable the local LabVIEW OLE/ActiveX server
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions:
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
server.tcp.access
Example: server.tcp.access="192.168.0.255","192.168.0.12"
Description: TCP/IP Access List
Datatype:
String
Permitted Values: Comma-separated list of IP adresses - each IP address must be enclosed in "quotation" marks
Default Value: Empty
LabVIEW Versions:
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
server.tcp.enabled
Example: server.tcp.enabled=TRUE
Description: Enable the local LabVIEW TCP/IP server
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: FALSE
LabVIEW Versions:
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
server.tcp.paranoid
Example: server.tcp.paranoid=FALSE
Description: Strict Checking
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions:
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
server.tcp.port
Example: server.tcp.port=3360
Description: TCP/IP server port number
Datatype:
Integer
Permitted Values: 1 to Unknown
Default Value: 3363
LabVIEW Versions:
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
server.vi.access
Example: server.vi.access="+*"
Description: Exported VIs list
Datatype:
String
Permitted Values: Unknown
Default Value: "+*"
LabVIEW Versions:
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
server.vi.callsEnabled
Example: server.vi.callsEnabled=FALSE
Description: Allow VI Calls
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions:
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
server.vi.propertiesEnabled
Example: server.vi.propertiesEnabled=FALSE
Description: Allow VI Methods and Properties
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: TRUE
LabVIEW Versions:
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
tcpServer.log
Example: tcpServer.log=TRUE
Description: Enable TCP/IP server logging
Datatype:
Boolean
Permitted Values: TRUE or FALSE
Default Value: FALSE
LabVIEW Versions:
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
tcpServer.logDetails
Example: tcpServer.logDetails=
Description: Unknown
Datatype:
Unknown
Permitted Values:
Default Value:
LabVIEW Versions:
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None
tcpServer.logPath
Example: tcpServer.logPath=FALSE
Description: TCP/IP server logging filepath
Datatype:
Path
Permitted Values: Any filepath
Default Value: Empty
LabVIEW Versions:
5.x,
6.x,
7.x,
8.x,
OS's Supported:
Notes: None